Plan Review Details - Permit 03030196
Plan Review Stops For Permit 03030196
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-04-14 Cont ID  
Sent By rmcdouga Date 2003-04-14 Time 12:49 Rev Time 3.00
Received By rmcdouga Date 2003-04-14 Time 12:48 Sent To  
Notes
2003-04-14 00:00:00PROVISO
  
 1) SUBMIT A SOIL BORING TEST REPORT AS
 REQUIRED BY FBC 1804.2.2 PRIOR TO
 POURING FOUNDATION.
  
 2) SUBMIT REVISED INSTALLATION SCHEDULE
 FOR STORM PANELS.
  
 3) PROVIDE (2) CURRENT COPIES OF SBCCI
 OR METRO-DADE PRODUCT APPROVALS FOR
 OUTSWING GLAZED DOOR AT CABANA BATH.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-04-03 Cont ID  
Sent By dpalmer Date 2003-04-14 Time 09:13 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2003-04-03 00:00:00DENIED
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) INDICATE THE LOCATION AND SIZE OF THE
 ATTIC ACCESS TO THE AREA ABOVE THE
 MASTER BEDROOM.
  
 3) THE ROOF SHEATHING NAIL SPACING GIVEN
 ON SHEET GN1 IS INCORRECT. SEE CITY OF
 WPB AMENDMENTS TO FBC TABLE 2306.1.
  
 4) THE EXTERIOR STUCCO SOFFIT SPECS. #7
 ON A5 STATES THAT METAL LATH IS TO BE
 ATTACHED NOT MORE THAN 6" APART. ASTM C
 1063 REQUIRES 3/8" RIB LATH TO BE
 ATTACHED AT EVERY RIB (4" O.C.). PLEASE
 REVISE.
  
 5) THE GIRDER AT THE SECOND FLOOR ABOVE
 BEDROOM #2 WITH AN UPLIFT OF 5455# AND
 BEARING ON THE (3) 2X6 HAS THE WRONG
 CONNECTOR SPECIFIED. SEE SHEET S3. THE
 DETAIL THAT IS SPECIFIED SHOWS A USP
 USC 53 ATTACHED TO A MASONRY WALL.
 NOTE: SOME HOLDOWN STRAPS MAY NOT WORK
 AT THIS LOCATION DUE TO PROXIMITY TO THE
 CORNER.
  
 6) THE TRUSS/GIRDER CONNECTION DETAIL ON
 S-3 SHOWS A 2X4 STUD WALL. THE WALL IS
 ACTUALLY A 2X6 STUD WALL. PLEASE CORRECT
  
 7) SPECIFY THE SPECIAL ROOF SHEATHING
 NAILING REQUIREMENTS REQUIRED BY CITY OF
 WPB AMENDMENTS TO FBC TABLE 2306.1.
 INDICATE FASTNER TYPE, SPACING, AND
 ZONES.
  
 8) SPECIFY THE LENGTH OR EMBED DEPTH OF
 THE 1/2" DIA. EXPANSION ANCHORS AT THE
 WD. FRAME TO CONCRETE WALL DETAIL ON A6.
  
 9) THE OWNER/AGENT IS REQUIRED TO SIGN
 THE ENERGY CALC. FORM.
  
 10) THE OPENING SIZES GIVEN ON THE STORM
 PANEL SCHEDULE DO NOT MATCH THE WINDOW
 SIZES ON THE PLANS FOR NUMBERS 1,2,18 &
 19. NUMBERS 18 & 19 WERE CHANGED BY THE
 ARCHITECT TO MEET EGRESS REQUIREMENTS.
 ITEM #1 DOES NOT LIST THE HEIGHT OR SPAN
 PLEASE CORRECT.
  
 11) PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR THE GLAZED FRENCH DOOR AT
 THE CABANA BATH.
  
 12) PROVIDE A SOIL BORING TEST REPORT AS
 REQUIRED BY FBC 1804.2.2.
  
 NOTE: PLEASE RETURN ALL OLD SHEETS OF
 DRAWINGS WHEN RESUBBING NEW PLANS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-07-31 Cont ID  
Sent By btrobaug Date 2003-07-31 Time 11:29 Rev Time 0.50
Received By btrobaug Date 2003-07-31 Time 11:14 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-04-14 Cont ID  
Sent By alange Date 2003-07-22 Time 15:33 Rev Time 0.33
Received By dpalmer Date 2003-04-14 Time 09:09 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-03-18 Cont ID  
Sent By shernand Date 2003-04-10 Time 11:42 Rev Time 0.25
Received By dpalmer Date 2003-03-18 Time 20:01 Sent To P
Notes
2003-03-18 00:00:00********** NOTES/ PROVISO *********
  
 1)NOTES: PLEASE SEE OCP AND AWG SHOWN
 FOR AHU#1. PLEASE SEE 424-3B
 10KW UNIT?
  
 2)NOTE: PLEASE PROVIDE OCP FOR SP/ PUMP.
  
  
 PLEASE REVISE AND SUBMIT BEFORE ROUGH.
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 EELCTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-07-22 Cont ID  
Sent By alange Date 2003-07-22 Time 15:33 Rev Time 0.00
Received By alange Date 2003-07-22 Time 15:33 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-04-10 Cont ID  
Sent By shernand Date 2003-04-10 Time 11:42 Rev Time 0.00
Received By shernand Date 2003-04-10 Time 11:42 Sent To E
Notes
2003-04-10 00:00:00DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-03-06 Cont ID  
Sent By dpalmer Date 2003-03-06 Time 11:55 Rev Time 0.00
Received By dpalmer Date 2003-03-06 Time 11:54 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-03-25 Cont ID  
Sent By jleech Date 2003-03-19 Time 17:08 Rev Time 0.33
Received By rregueir Date 2003-03-25 Time 19:01 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-03-19 Cont ID  
Sent By dpalmer Date 2003-03-18 Time 20:01 Rev Time 0.33
Received By jleech Date 2003-03-19 Time 17:07 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-03-10 Cont ID  
Sent By dpalmer Date 2003-03-06 Time 11:56 Rev Time 0.00
Received By sgraham Date   Time   Sent To P
Notes
***NONE***