Plan Review Details - Permit 03030011
Plan Review Stops For Permit 03030011
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-04-28 Cont ID  
Sent By rbrown Date 2003-04-28 Time 10:08 Rev Time 0.00
Received By rbrown Date 2003-04-28 Time 10:08 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-04-03 Cont ID  
Sent By dpalmer Date 2003-04-24 Time 14:00 Rev Time 0.00
Received By rbrown Date 2003-04-03 Time 10:09 Sent To  
Notes
2003-04-03 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 MODEL A
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
  
 1) BOUNDARY LINE SURVEY. IF THE ADJACENT
 LOT REQUIRES AN EASEMENT ON THIS LOT,
 FOR SECONDARY EGRESS FROM BEDROOMS, THEN
 THE EGRESS EASEMENT MUST BE SHOWN ON THE
 SURVEY DRAWINGS FOR THIS LOT AND THAT OF
 THE ADJACENT LOT AFFECTED.
  
 2) SHEET S-1, ROOF FRAMING PLAN.SUBMIT
 CALCULATIONS OR A SIGNED AND SEALED
 LETTER FROM THE ENGINEER TO VERIFY THAT
 THE EAVES UPLIFT LOAD OVER THE REAR
 COVERED PATIO IS ONLY 268 LB.
  
 3) SHEET S-1, ROOF FRAMING PLAN.ADD A
 KEY, FOR THE TRUSS ANCHOR REFERENCE
 ANNOTATION, TO CONFIRM IF1MEANS
 CONNECTOR MARK 1, AND IF 'U' IS THE
 DESIGN UPLIFT CAPACITY REQUIRED.WHAT
 IS THE VALUE STATED AS 'R', IS IT THE
 REQUIRED LATERAL LOAD CAPACITY (EITHER
 F1 OR F2)?
  
 4) SHEET S-2, CONNECTOR SCHEDULE.AMEND
 THE SCHEDULE TO INCLUDE THE UPLIFT AND
 THE LATERAL LOAD CAPACITY FOR THE
 SELECTED ANCHORS AND LUMBER GRADE.
  
 5) FBC TABLE 600THE GLASS BLOCK WINDOW
 IS ON THE PROPERTY LINE.AMEND THE
 PLANS TO SHOW THE REQUIREMENT FOR A ONE-
 HOUR FIRE-RATED ASSEMBLY.
  
 6) SHEET S3, PLYWOOD NAILING DETAIL.
 AMEND '10/32 CDX PLYWOOD' TO READ
 '19/32 CDX PLYWOOD'.
  
 7) PROVISO - ROOF TILE PRODUCT APPROVAL
 NOA# 99-1012.02 HAS EXPIRED.SUBMIT A
 CURRENT PRODUCT APPROVAL.
  
 8) PROVISO - OUTSWING STEEL DOUBLE DOOR
 PRODUCT APPROVAL NOA# 99-0311.03 HAS
 EXPIRED.SUBMIT A CURRENT PRODUCT
 APPROVAL.
  
 9) PROVISO - ALUMINUM SLIDING GLASS DOOR
 PRODUCT APPROVAL NOA# 98-1228.01 HAS
 EXPIRED.SUBMIT A CURRENT PRODUCT
 APPROVAL.
  
 10) PROVISO - ALUMINUM TUBE MULLION
 PRODUCT APPROVAL NOA# 99-0310.01 HAS
 EXPIRED.SUBMIT A CURRENT PRODUCT
 APPROVAL.
  
 11) PROVISO - SINGLE HUNG WINDOW PRODUCT
 APPROVAL NOA# 98-1222.02 HAS EXPIRED.
 SUBMIT A VALID PRODUCT APPROVAL.
  
 12) SHEET S-1, ROOF FRAMING PLAN.
 CONNECTOR MARK 5, SPECIFIED FOR THE
 EAVES OVER THE REAR COVERED PATIO, IS A
 SIMPSON TS9.THIS IS A TWIST STRAP FOR
 WOOD-TO-WOOD CONNECTIONS AND IS NOT
 SUITABLE FOR CONNECTION TO THE
 8F16-1B/1T FILLED CAVITY U-BEAM
 SPECIFIED FOR THIS LOCATION.AMEND THE
 REFERENCE.
  
 13) SHEET S-1, ROOF FRAMING PLAN.A
 CONNECTOR MARK 18 IS SPECIFIED IN FOUR
 LOCATIONS FOR THE ROOF OVER THE FRONT
 ENTRANCE PORCH.THERE IS NO MARK 18 ON
 THE CONNECTOR SCHEDULE (SHEET S2).
 AMEND THE REFERENCE.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 IF YOU HAVE ANY QUESTIONS PLEASE CALL:
 ROBERT BROWN(561) 659 8096 EXT 8499

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2003-08-28 Cont ID  
Sent By dpalmer Date 2003-08-28 Time 12:38 Rev Time 0.25
Received By dpalmer Date 2003-08-28 Time 12:38 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-08-04 Cont ID  
Sent By dpalmer Date 2003-08-04 Time 10:12 Rev Time 0.25
Received By dpalmer Date 2003-08-04 Time 10:11 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-04-24 Cont ID  
Sent By alange Date 2003-08-01 Time 14:35 Rev Time 0.25
Received By dpalmer Date 2003-04-24 Time 14:00 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-03-18 Cont ID  
Sent By shernand Date 2003-04-17 Time 16:24 Rev Time 0.25
Received By dpalmer Date 2003-03-18 Time 06:28 Sent To P
Notes
2003-03-18 00:00:00**************** UNSAT *****************
  
 PLEASE SEE NOTES UNDER #03022281.
 PLEASE NOTE, MOST NOTES ARE THE SAME.
 IF THERE ARE ANYQUESTIONS, PLEASE CALL
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-08-01 Cont ID  
Sent By alange Date 2003-08-01 Time 14:35 Rev Time 0.00
Received By alange Date 2003-08-01 Time 14:35 Sent To E
Notes
2003-08-01 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-04-17 Cont ID  
Sent By shernand Date 2003-04-17 Time 16:24 Rev Time 0.00
Received By shernand Date 2003-04-17 Time 16:24 Sent To E
Notes
2003-04-17 00:00:00DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-03-04 Cont ID  
Sent By dpalmer Date 2003-03-04 Time 08:37 Rev Time 0.00
Received By dpalmer Date 2003-03-04 Time 08:37 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-03-22 Cont ID  
Sent By jleech Date 2003-03-18 Time 19:00 Rev Time 0.25
Received By hmoser Date 2003-03-22 Time 12:04 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-03-18 Cont ID  
Sent By dpalmer Date 2003-03-18 Time 06:28 Rev Time 0.25
Received By jleech Date 2003-03-18 Time 19:00 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-03-04 Cont ID  
Sent By dpalmer Date 2003-03-04 Time 08:37 Rev Time 0.00
Received By sgraham Date   Time   Sent To P
Notes
***NONE***