Plan Review Details - Permit 03030010
Plan Review Stops For Permit 03030010
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-05-06 Cont ID  
Sent By rbrown Date 2003-05-06 Time 16:57 Rev Time 0.00
Received By rbrown Date 2003-05-06 Time 16:57 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-05-01 Cont ID  
Sent By shernand Date 2003-05-05 Time 10:59 Rev Time 0.00
Received By rbrown Date 2003-05-01 Time 09:43 Sent To  
Notes
2003-05-01 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 MODEL D
  
 1) SHEET S-1, ROOF FRAMING PLAN.THE
 ROOF TRUSS ANCHOR AT THE WALL BETWEEN
 THE ATRIUM AND BEDROOM 2 IS CALLED UP AS
 DETAIL 5/S-4. SHEET S-4 HAS NO DETAIL 5.
 AMEND THE PLANS TO CORRELATE THE DETAILS
 IF THE REFERENCE ON THE ROOF FRAMING
 PLAN SHOULD BE TO DETAIL 4/S-4, AS DRAWN
 ON SHEET S-4, THEN THE COPIES OF
 SHEET S-1 MAY BE HAND-CORRECTED BY THE
 ENGINEER OF RECORD.SUCH A CORRECTION
 SHALL BE SIGNED AND DATED BY THE
 ENGINEER.
  
 2) SHEET S-1, ROOF FRAMING PLAN.THE
 HIP JACK ANCHOR AT THE PATIO COLUMN IS
 CALLED UP AS CONNECTOR MARK 8.THE
 CONNECTOR SCHEDULE ON S-2 DOES NOT
 INCLUDE A MARK 8.AMEND THE PLANS.
  
 3) NOTE: IF SHEET S-2 IS TO BE AMENDED,
 PLEASE CORRECT THE CONNECTOR MARK 4
 (SIMPSON MGT) ALLOWABLE UPLIFT TO 3965#
 (CURRENTLY SHOWN AS 4200#).
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 TELEPHONE: (561) 805 6716ROBERT BROWN
 E-MAIL: [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-04-10 Cont ID  
Sent By dpalmer Date 2003-04-24 Time 07:20 Rev Time 0.00
Received By rbrown Date 2003-04-10 Time 08:29 Sent To  
Notes
2003-04-10 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 MASTER D
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
  
 1) THE SUBMITTED NOTICE OF COMMENCEMENT
 SHOWS AN DIFFERENT PROPERTY CONTROL
 NUMBER.SUBMIT THE CORRECT NOTICE OF
 COMMENCEMENT.
  
 2) BOUNDARY LINE SURVEY. IF THE ADJACENT
 LOT 24 REQUIRES AN EASEMENT ON LOT 25,
 FOR SECONDARY EGRESS FROM BEDROOMS, THEN
 THE EGRESS EASEMENT MUST BE SHOWN ON THE
 SURVEY DRAWING FOR THIS LOT AND THAT OF
 LOT 24.
  
 3) SHEET S-2, CONNECTOR SCHEDULE.
 MARK 3, LVS26 IS NOT A VALID SIMPSON
 REFERENCE.SHOULD THIS BE LUS26?AMEND
 THE SCHEDULE.
  
 4) SHEET S-1, ROOF FRAMING PLAN.ADD A
 KEY, FOR THE TRUSS ANCHOR REFERENCE
 ANNOTATION, TO CONFIRM IF1MEANS
 CONNECTOR MARK 1, AND IF 'U' IS THE
 DESIGN UPLIFT CAPACITY REQUIRED.WHAT
 IS THE VALUE STATED AS 'R', IS IT THE
 REQUIRED LATERAL LOAD CAPACITY (EITHER
 F1 OR F2)?
  
 5) SHEET S-2, CONNECTOR SCHEDULE.AMEND
 THE SCHEDULE TO INCLUDE THE UPLIFT AND
 THE LATERAL LOAD CAPACITY FOR THE
 SELECTED ANCHORS AND LUMBER GRADE.
  
 6) FBC TABLE 600THE GLASS BLOCK WINDOW
 IS ON THE PROPERTY LINE.AMEND THE
 PLANS TO SHOW THE REQUIREMENT FOR A ONE-
 HOUR FIRE-RATED ASSEMBLY.
  
 7) SHEET S3, PLYWOOD NAILING DETAIL.
 AMEND '10/32 CDX PLYWOOD' TO READ
 '19/32 CDX PLYWOOD'.
  
 8) PROVISO - ROOF TILE PRODUCT APPROVAL
 NOA# 99-1012.02 HAS EXPIRED.SUBMIT A
 CURRENT PRODUCT APPROVAL.
  
 9) PROVISO - OUTSWING STEEL DOUBLE DOOR
 PRODUCT APPROVAL NOA# 99-0311.03 HAS
 EXPIRED.SUBMIT A CURRENT PRODUCT
 APPROVAL.
  
 10) PROVISO - ALUMINUM SLIDING GLASS
 DOOR PRODUCT APPROVAL NOA# 98-1228.01
 HAS EXPIRED.SUBMIT A CURRENT PRODUCT
 APPROVAL.
  
 11) PROVISO - ALUMINUM TUBE MULLION
 PRODUCT APPROVAL NOA# 99-0310.01 HAS
 EXPIRED.SUBMIT A CURRENT PRODUCT
 APPROVAL.
  
 12) PROVISO - SINGLE HUNG WINDOW PRODUCT
 APPROVAL NOA# 98-1222.02 HAS EXPIRED.
 SUBMIT A VALID PRODUCT APPROVAL.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 IF YOU HAVE ANY QUESTIONS PLEASE CALL:
 ROBERT BROWN(561) 659 8096 EXT 8499

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2003-09-25 Cont ID  
Sent By dpalmer Date 2003-09-25 Time 06:20 Rev Time 0.25
Received By dpalmer Date 2003-09-25 Time 06:20 Sent To  
Notes
2003-09-25 00:00:00FLD LT LTR.

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2003-09-22 Cont ID  
Sent By csiegber Date 2003-09-24 Time 16:36 Rev Time 0.25
Received By dpalmer Date 2003-09-22 Time 20:25 Sent To  
Notes
2003-09-22 00:00:00*************** UNSAT ****************
  
 1)NOTE: PLEASE SEEFS 471.025/ FAC
 61G15-23.002. LETTERS MUST HAVE ORIGINAL
 SIGNATURE/DATE. NOT COPIES.
 PLEASE ALSO PROVIDE CERTIFICATE OF
 AUTHORIZATION # ON TITLE BLOCK.
  
 2)NOTE: PLEASE ALSO SEE THAT LETTERS
 ARE MADE OUT TO PALM BEACH COUNTY PZB,
 100 AUST. AVE/
 WORK IS DONE IN THE CITY OF WEST PALM
 BEACH, CONSTRUCTIONSERVICES DEPT.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-09-02 Cont ID  
Sent By dpalmer Date 2003-09-02 Time 07:47 Rev Time 0.25
Received By dpalmer Date 2003-09-02 Time 07:47 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-04-24 Cont ID  
Sent By dpalmer Date 2003-04-24 Time 07:20 Rev Time 0.25
Received By dpalmer Date 2003-04-24 Time 07:20 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-03-18 Cont ID  
Sent By shernand Date 2003-04-17 Time 14:41 Rev Time 0.25
Received By dpalmer Date 2003-03-18 Time 06:15 Sent To P
Notes
2003-03-18 00:00:00************* UNSAT ****************
  
 PLEASE SEE NOTES UNDER #03022281.
 PLEASE NOTE, MOST OF THE NOTES ARE THE
 SAME.
  
 IF THERE ARE ANY QUESTIONS,PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-09-24 Cont ID  
Sent By csiegber Date 2003-09-24 Time 16:36 Rev Time 0.00
Received By csiegber Date 2003-09-24 Time 16:35 Sent To E
Notes
2003-09-24 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-05-05 Cont ID  
Sent By shernand Date 2003-05-05 Time 10:58 Rev Time 0.00
Received By shernand Date 2003-05-05 Time 10:58 Sent To B
Notes
2003-05-05 00:00:00RBROWN DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-04-17 Cont ID  
Sent By shernand Date 2003-04-17 Time 14:41 Rev Time 0.00
Received By shernand Date 2003-04-17 Time 14:41 Sent To E
Notes
2003-04-17 00:00:00DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-03-04 Cont ID  
Sent By dpalmer Date 2003-03-04 Time 08:37 Rev Time 0.00
Received By dpalmer Date 2003-03-04 Time 08:37 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-03-22 Cont ID  
Sent By jleech Date 2003-03-18 Time 18:11 Rev Time 0.25
Received By hmoser Date 2003-03-22 Time 13:01 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-03-18 Cont ID  
Sent By dpalmer Date 2003-03-18 Time 06:15 Rev Time 0.25
Received By jleech Date 2003-03-18 Time 18:11 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-03-04 Cont ID  
Sent By dpalmer Date 2003-03-04 Time 08:37 Rev Time 0.00
Received By sgraham Date   Time   Sent To P
Notes
***NONE***