Plan Review Stops For Permit 03022335 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
7 |
Status |
P |
Date |
2004-02-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2004-02-05 |
Time |
12:53 |
Rev Time |
1.00 |
Received By |
shill |
Date |
2004-02-05 |
Time |
12:52 |
Sent To |
|
|
Notes |
2004-02-05 00:00:00 | REVISION A4 & A5 1/27/04 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
F |
Date |
2004-01-22 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-01-28 |
Time |
14:26 |
Rev Time |
1.00 |
Received By |
shill |
Date |
2004-01-22 |
Time |
10:38 |
Sent To |
|
|
Notes |
2004-01-22 00:00:00 | *****CORRECTIONS***** | | *****REVISION******* | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 | | | | 1.)SEE PREVIOUS LISTS, 9/16 #6 AND | | 12/17 #4.WOOD-TO-WOOD CONNECTORS USED | | IN A WOOD-TO-MASONRY APPLICATION REQUIRE | | EITHER DOCUMENTATION FROM THE | | MANUFACTURER OR CALCULATIONS FROM THE | | DESIGNER.SEE ALSO ATTACHED FS553.80(2) | | (B).A 4X PLAN REVIEW FEE HAS BEEN | | CHARGED AS PER FLORIDA STATUTE AND WILL | | BE CHARGED EACH TIME THE PLAN IS | | RESUBMITTED WITHOUT THE REQUIRED | | INFORMATION. | | | | 2.)DO NOT BRING IN REVISIONS AS | | SUBMITTALS AT THE FRONT COUNTER. | | A BZ WAS ISSUED FOR THE LAST REVISION. | | PAY ALL FEES BEFORE RESUBMITTAL. RETURN | | THE OLD BZ WHICH WAS NOT PAID.NEW | | BZ235306, $1333.28 ATTACHED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2003-12-17 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-01-08 |
Time |
16:50 |
Rev Time |
1.00 |
Received By |
shill |
Date |
2003-12-17 |
Time |
11:15 |
Sent To |
|
|
Notes |
2003-12-17 00:00:00 | ****CORRECTIONS****** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | [email protected] | | | | 1.)SEE CORRECTION LIST DATED 9/16/03. | | THE PREVIOUS REVISION HAD BEEN ISSUED | | WITH A PROVISO THAT ITEMS #6 AND #7 | | AFFECTING SHEETS A4 AND A5 (CONNECTORS) | | BE REVISED.THESE ITEMS WERE NOT | | ADDRESSED PROPERLY. | | | | 2.)SEE ITEM #7, THERE ARE STILL | | REFERENCES TO "LONG STRAPS".WHICH | | STRAPS SHOULD BE USED?SPECIFY A | | BRAND AND SPECIFIC CONNECTOR. | | | | 3.)SEE PREVIOUS LIST, ITEM #6.THE | | CONNECTORS' DESIGN UPLIFT EXCEEDS THE | | UPLIFT ALLOWED AS PER THE MANUFACTURER. | | SEE ATTACHED.FOR USP, USE THE GREY BAR | | SHOWING NO STRESS INCREASE FOR STEEL. | | FOR MORE INFORMATION, SEE THE USP | | CATALOG PP 6-7 IN REGARDS TO FBC1609.4. | | | | 4.)SEE PREVIOUS LIST, ITEM #6.YOU | | HAVE SPECIFIED WOOD-TO-WOOD CONNECTORS | | IN A WOOD-TO-MASONRY APPLICATION. EITHER | | SPECIFY A DIFFERENT CONNECTOR, SUBMIT | | ENGINEERING FROM THE MANUFACTURER | | SHOWING THAT THIS CONNECTOR CAN BE | | USED AND HAS BEEN TESTED IN THIS | | APPLICATION, OR SUBMIT CALCULATIONS | | SHOWING THAT THIS CONNECTOR CAN BE | | USED IN THIS APPLICATION. | | | | 5.)ADDITIONAL FEES, $70 (REVISION FEE, | | NO FREE RESUB FOR REVISIONS),BZ231391. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2003-10-06 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-12-16 |
Time |
10:35 |
Rev Time |
2.00 |
Received By |
sthyng |
Date |
2003-10-02 |
Time |
10:22 |
Sent To |
|
|
Notes |
2003-10-06 00:00:00 | ****PROVISO**** | | SUBMIT REVISION FOR SHEETS A4 AND A5 | | BEFORE ROOF FRAMING | | | | ISSUED W/PROVISO AS PER CONTRACTOR'S | | REQUEST | | | | REVISION |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2003-09-16 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-10-01 |
Time |
06:44 |
Rev Time |
3.50 |
Received By |
sthyng |
Date |
2003-09-15 |
Time |
17:02 |
Sent To |
|
|
Notes |
2003-09-15 00:00:00 | *****CORRECTIONS***** | | *****REVISION****** | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | [email protected] | | | | 1.)ADDITIONAL FEES DUE, $36.26. | | BZ#230485 ATTACHED; PLEASE PAY AT | | CASHIER (INCREASED VALUE, RADON). | | | | 2.)IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY.THE PLANS MUST BE | | STAMPED AND THE RECEIPT ATTACHED TO THE | | APPLICATION.233-5025 | | | | 3.)THE MINIMUM WALL INSULATION AS PER | | THE ENERGY CALCS SUBMITTED IS R5. REVISE | | ALL APPLICABLE DETAILS, INCLUDING | | WINDOW JAMB A2, STEMWALL SECTION A4, | | WALL SECTION A4. | | | | 4.)ON THE WALL SECTION, A4, LOWEST | | BUILDING FLOOR ELEVATION SHALL BE A MIN. | | 4" ABOVE FINISHED GRADE, CITY OF WEST | | PALM BEACH AMENDMENTS FBC1804.1.7. | | | | 5.)WALL SECTION, A4, BOTTOM OF FOOTER | | IS REQUIRED TO BE A MINIMUM OF 12" BELOW | | FINISHED GRADE, FBC1804.1.3. | | | | 6.)A5, USP TRUSS TIE DOWN SCHEDULE, | | UPLIFT ON SCHEDULE EXCEEDS MAXIMUM | | IN USP 2003 CATALOG FOR RT-T CONNECTORS. | | TARP HAS BEEN DISCONTINUED.RT-T IS | | A WOOD-TO-WOOD CONNECTOR AND CANNOT BE | | USED IN A WOOD-TO-MASONRY APPLICATION. | | THIS PERMIT WAS ISSUED WITH A PROVISO | | TO SUBMIT A NEW ATTACHMENT SCHEDULE. | | REVISE THE ATTACHMENT SCHEDULE, AND | | SPECIFY ALL ATTACHMENTS INCLUDING | | GIRDERS. | | | | 7.)THE ROOF PLAN A5, AND THE KNEE WALL | | SECTION REFER TO A "LONG FLAT STRAP". | | SPECIFY WHICH STRAP IS TO BE USED. | | | | 8.) THE PLANS SHOW EXISTING ROOF TRUSSES | | AND GIRDERS WHICH ARE TO BE RELOCATED. | | BE ADVISED THAT TRUSS ENGINEERING MUST | | BE PROVIDED AT THE TIME OF INSPECTION, | | INCLUDING THE EXISTING TRUSSES BEING | | RELOCATED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2003-05-13 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-09-12 |
Time |
08:39 |
Rev Time |
1.00 |
Received By |
sthyng |
Date |
2003-05-13 |
Time |
09:17 |
Sent To |
|
|
Notes |
2003-05-13 00:00:00 | ******PROVISO****** | | PROVIDE NEW CONNECTOR | | UPLIFT INFORMATION | | BASED ON 2003 CATALOG. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-04-18 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-05-05 |
Time |
07:36 |
Rev Time |
4.00 |
Received By |
sthyng |
Date |
2003-04-17 |
Time |
12:26 |
Sent To |
|
|
Notes |
2003-04-18 00:00:00 | **********CORRECTIONS************ | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | FILED WITH THE CLERK OF COURTS BEFORE | | A PERMIT CAN BE ISSUED. | | | | 2.) BEFORE A PERMIT TO CONSTRUCT MAY | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | SET OF PLANS MUST BE STAMPED BY THAT | | OFFICE, AND A COPY OF THE PAID RECEIPT | | ATTACHED TO THE PERMIT APPLICATION. | | PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION.THIS MAY BE DONE AFTER THE | | FINAL PLAN REVIEW, BUT BEFORE A PERMIT | | MAY BE ISSUED. | | | | 3.)THE WINDOW JAMB AND DOOR JAMB | | DETAILS REFER TO AN ATTACHMENT SCHEDULE | | WHICH IS NOT ON THE PLAN.ALSO REFERS | | TO A DOOR ATTACHMENT WHICH IS | | INCOMPLETE. | | | | 4.)FBC 1918.3.1, GABLE MUST BE | | STRUCTURALLY CONTINUOUS BETWEEN POINTS | | OF LATERAL SUPPORT.PLEASE ADDRESS. | | | | 5.)NOTE #5, SHEET A-4, PLYWOOD | | SHEATHING NOTE DOES NOT MEET CITY OF | | WEST PALM BEACH REVISED TABLE 2306.1 | | FASTENING SCHEDULE.PROVIDE A CORRECT | | ROOF SHEATHING FASTENING SCHEDULE (SEE | | ATTACHED). | | | | 6.)THIS PROPERTY IS LOCATED IN THE A5 | | FLOOD ZONE.CITY CODE SECTION 94-545 | | REQUIRES THAT THE ADDITION HAVE A | | FINISHED FLOOR ELEVATION OF 6" ABOVE THE | | BASE FLOOD ELEVATION, WHICH IS 7'.THE | | FINISHED FLOOR IS REQUIRED TO BE AT 7'6" | | BUT THE PLAN SHOWS 7'.PLEASE REVISE. | | | | 7.)FYI - HUGHES BRAND IS NO LONGER | | AVAILABLE. | | | | 8.)SHOW HORIZONTAL REINFORCEMENT | | FOR COLUMNS IN THE WALL SECTION. | | | | 9.)THE BOND BEAM IS REFERRED TO AS | | BOTH A SINGLE AND DOUBLE COURSE.PLEASE | | CLARIFY. | | | | 10.)ON THE ENERGY CALC FORM, SIGN | | THE OWNER/AGENT LINE ON BOTH COPIES. | | | | 11.)ADDITIONAL FEES REQUIRED. | | | | IF YOU HAVE ANY QUESTION, PLEASE CALL | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2004-04-20 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-04-20 |
Time |
11:27 |
Rev Time |
50.00 |
Received By |
dpalmer |
Date |
2004-04-20 |
Time |
11:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2003-09-26 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-04-16 |
Time |
14:27 |
Rev Time |
0.75 |
Received By |
dpalmer |
Date |
2003-09-26 |
Time |
09:41 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2003-08-25 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-09-24 |
Time |
14:44 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2003-08-25 |
Time |
13:30 |
Sent To |
P |
|
Notes |
2003-08-25 00:00:00 | **************** UNSAT ************* | | | | PLEASE SEE NOTES SET FORTH FROM ORIGINAL | | PROVISO. PLEASE SEE THAT SOME ITEMS | | WERE NOT CORRECTED. | | | | 1)NOTE: PLEASE SEE 250-66 FOR GROUNDING | | ELECTRODE CONDUCTOR. ONE SHOWN AT #4, | | OTHER SHOWN AT #6.? | | | | 2)NOTE: PLEASE SEE MISSING EQUIPMENT | | GROUNDING CONDUCTOR FROM MAIN DISCONNECT | | TO PANEL. 250-24/250-122 | | | | 3)NOTE: PLEASE SEE MISSING FRONT AND | | REAR RECEPTS. 210-52E | | | | 4)NOTE: PLEASE SEE MISSING BATH RECEPT | | FOR BATH / POWDER RM. 210-52D | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2003-05-05 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-18 |
Time |
11:51 |
Rev Time |
0.75 |
Received By |
dpalmer |
Date |
2003-05-05 |
Time |
07:22 |
Sent To |
B |
|
Notes |
2003-05-05 00:00:00 | ************PROVISO/REVISE ************ | | | | PLANS STILL MISSING THE FOLLOWING AND | | NEED TO BE REVISED BEFORE FINAL. | | | | 1)NOTE: PLEASE SHOW SD`S INSIDE AND | | OUTSIDE BEDROOM. NFPA-72 8-1.4.2 | | | | 2)NOTE: PLEASE SHOW EQUIPMENT GROUNDING | | CONDUCTOR BETWEEN MAIN DISC AND PANEL. | | 250-24/250-122 | | | | 3)NOTE: PLEASE SHOW ALL KITCHEN COUNTER- | | -SPACE RECEPTS AS GFI/GFI PROTECTED. | | 210-8-A-6 | | | | 4)NOTE: PLEASE SEE MISSING REAR RECEPT | | PER 210-52E. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW BEFORE FINAL. IF THERE ARE ANY | | QUESTIONS, PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2003-04-03 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-28 |
Time |
14:21 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2003-04-03 |
Time |
04:50 |
Sent To |
P |
|
Notes |
2003-04-03 00:00:00 | **************** UNSAT ************** | | | | 1)NOTE : PLEASE SUBMIT AIC RATING FOR | | ALL NEW EQUIPMENT BEING INSTALLED. PER | | 110-9/215-5 | | MAINS/PANELS/BRKRS ARE ALL TO BE RATED | | FOR THE AVAILABLE FAULT CURRENT. | | | | 2)NOTE: PLEASE SIZE GROUNDING ELECTRODE | | PER 250-66. | | | | 3)NOTE: PLEASE SEE MISSING EQUIPMENT | | GROUNDING CONDUCTOR BETWEEN MAIN DISC | | AND PANEL. | | | | 4)NOTE: PLEASE LIST THE REQ`D ARC FAULT | | PROTECTED CIRCUITS PER 210-12 ON PANEL | | SCHEDULE. | | | | 5)NOTE: PLEASE CLARIFY ONLY ONE SMALL | | APPLIANCE CIRCUIT SHOWN ON PANEL SCHED? | | PLEASE NOTE, A MIN OF TWO IS REQ`D PER | | NEC 210-11C-1 | | | | 6)NOTE: PLEASE SEE FS/FAC 481/ 61G14 | | PLEASENOTE, ALL CHANGES TO PLANS THAT | | ARE SIGNED AND SEALED BY AND ARCH, MUST | | HAVE "EACH" HANDWRITTEN CHANGE, | | INITIALED, DATED BY ARCH OF RECORD. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
14 |
Status |
N |
Date |
2004-04-16 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-04-16 |
Time |
14:27 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-04-16 |
Time |
14:27 |
Sent To |
E |
|
Notes |
2004-04-16 00:00:00 | TO DP DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
13 |
Status |
N |
Date |
2004-01-28 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-01-28 |
Time |
14:26 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-01-28 |
Time |
14:26 |
Sent To |
B |
|
Notes |
2004-01-28 00:00:00 | TO SH DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
12 |
Status |
N |
Date |
2004-01-08 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-01-08 |
Time |
16:50 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-01-08 |
Time |
16:50 |
Sent To |
B |
|
Notes |
2004-01-08 00:00:00 | TO SH DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
11 |
Status |
N |
Date |
2003-12-16 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-12-16 |
Time |
10:35 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-12-16 |
Time |
10:35 |
Sent To |
B |
|
Notes |
2003-12-16 00:00:00 | TO SH DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
10 |
Status |
N |
Date |
2003-09-24 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-09-24 |
Time |
14:44 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-09-24 |
Time |
14:44 |
Sent To |
E |
|
Notes |
2003-09-24 00:00:00 | TO DP DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2003-08-18 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-18 |
Time |
11:47 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-08-18 |
Time |
11:46 |
Sent To |
E |
|
Notes |
2003-08-18 00:00:00 | TO DP DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2003-08-18 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2003-08-18 |
Time |
11:02 |
Rev Time |
0.00 |
Received By |
sthyng |
Date |
2003-08-18 |
Time |
09:59 |
Sent To |
Z |
|
Notes |
2003-08-18 00:00:00 | ADDITION - NEEDS ZONING |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2003-08-12 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2003-08-18 |
Time |
09:40 |
Rev Time |
0.00 |
Received By |
dbaxter |
Date |
2003-08-12 |
Time |
11:34 |
Sent To |
Z |
|
Notes |
2003-08-12 00:00:00 | TO ZONING BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2003-05-14 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-14 |
Time |
14:00 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-05-14 |
Time |
14:00 |
Sent To |
B |
|
Notes |
2003-05-14 00:00:00 | STHYNG DESK. SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2003-04-28 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-28 |
Time |
14:20 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-04-28 |
Time |
14:20 |
Sent To |
E |
|
Notes |
2003-04-28 00:00:00 | DP DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2003-04-17 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-17 |
Time |
11:51 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-04-17 |
Time |
11:51 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-03-24 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-03-24 |
Time |
08:12 |
Rev Time |
0.00 |
Received By |
sthyng |
Date |
2003-03-24 |
Time |
08:12 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-03-19 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-03-19 |
Time |
10:48 |
Rev Time |
0.00 |
Received By |
sthyng |
Date |
2003-03-19 |
Time |
10:48 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-02-28 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-02-28 |
Time |
17:08 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2003-02-28 |
Time |
17:07 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2003-10-01 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-10-01 |
Time |
06:44 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2003-10-01 |
Time |
06:44 |
Sent To |
B |
|
Notes |
2003-10-01 00:00:00 | PROVISO: | | PLEASE NOTE, REVISION TO THE 2001 | | FBC(M) 601.4, EFFECTIVE JUNE 30,2003: | | | | BALANCED AIR RETURN - RETURN/TRANSFER | | SHALL BE 1 1/2 TIMES THE CROSS SECTIONAL | | AREA (SQ INCHES) OF THE SUPPLY DUCT | | ENTERING THE ROOM ITS SERVING & THE | | DOOR HAVING AN UNRESTRICTED 1" UNDERCUT. | | | | ALL SUPPLY AIR INTO THE MASTER SUITE | | SHALL BE INCLUDED. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2003-09-12 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-09-30 |
Time |
12:35 |
Rev Time |
0.20 |
Received By |
pkrauss |
Date |
2003-09-12 |
Time |
08:38 |
Sent To |
B |
|
Notes |
2003-09-12 00:00:00 | PROVISO: | | | | BALANCED AIR REQUIRED AS PER 2001 FBC(M) | | 601.4, PLEASE PROVIDE RETURN AIR FROM | | BEDROOM AREAS.PLAN DOES NOT INDICATE | | DUCT OR GRILLE SIZE FOR RETURN AIR. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-04-04 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-09-03 |
Time |
16:10 |
Rev Time |
0.35 |
Received By |
pkrauss |
Date |
2003-04-04 |
Time |
10:09 |
Sent To |
B |
|
Notes |
2003-04-04 00:00:00 | MECHANICAL PERMIT 03040041 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2003-09-30 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-09-30 |
Time |
12:35 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2003-09-30 |
Time |
12:35 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2003-09-03 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-09-26 |
Time |
09:41 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2003-09-03 |
Time |
16:07 |
Sent To |
M |
|
Notes |
2003-09-03 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | | | 1) SANITARY RISER DIAGRAM SHALL REFLECT | | THE CHANGES ON THE FLOOR PLAN. BATHROOM | | NEXT TO LAUNDRY ROOM SHOWS SHOWER DELET- | | ED, W/C & LAV MOVED TO ANOTHER WALL. | | IF BATHROOM #1 HAS BEEN CHANGED THEN THE | | RISER DIAGRAM SHALL REFLECT CHANGES. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2003-04-03 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-08-25 |
Time |
13:03 |
Rev Time |
0.25 |
Received By |
kstevens |
Date |
2003-04-03 |
Time |
17:49 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2003-08-18 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-08-18 |
Time |
09:59 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
Notes |
2003-08-18 00:00:00 | 8/18/03 DO NOT NEED ANY ZONING REVIEW | | PER TONI GELO CONTRACTOR/CONTACT PERSON | | MM | | 8/18/03 REVIEWED NEED ZONING PASS MM |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2003-03-21 |
|
|
Cont ID |
|
Sent By |
dbaxter |
Date |
2003-08-12 |
Time |
11:34 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2003-03-04 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-03-19 |
Time |
10:48 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2003-03-04 00:00:00 | DENIED, NEED A COMPLETE FLOOR PLAN | | OF EXISTING HOUSE |
|
|