Plan Review Stops For Permit 03021472 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2003-03-20 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-04-03 |
Time |
12:31 |
Rev Time |
2.00 |
Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2003-11-04 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-11-04 |
Time |
09:49 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2003-11-04 |
Time |
09:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2003-10-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-10-28 |
Time |
11:10 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2003-10-28 |
Time |
11:09 |
Sent To |
|
|
Notes |
2003-10-28 00:00:00 | ************* UNSAT **************** | | | | 1)NOTE: PLEASE CORRELATE RISER DIAGRAM | | AND RISER DIAGRM NOTES. NOTES MENTION | | 225A SERVICE AND RISER SHOWS 200A. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2003-04-03 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-04-03 |
Time |
12:31 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2003-04-03 |
Time |
12:31 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2003-03-12 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-02 |
Time |
15:01 |
Rev Time |
0.75 |
Received By |
dpalmer |
Date |
2003-03-12 |
Time |
14:35 |
Sent To |
P |
|
Notes |
2003-03-12 00:00:00 | ************** UNSAT ***************** | | | | 1)NOTE: PLEASE SEE MISSING SD IN ROOM | | AT FRONT DOOR W/ CLOSET. NFPA-72 8-1.4.2 | | | | 2)NOTE: PLEASE SEE MISSING EGRESS LIGHT- | | ING AND CONTROL AT BACK DOOR. 210-70 | | | | 3)NOTE: PLEASE SHOW ALL OUTLETS SERVING | | KITCHEN COUNTERSPACE AS GFI/GFI | | PROTECTED.210-8-A-6 | | | | 4)NOTE: PLEASE SEE MISSING SOME RECEPTS | | FOR KITCHEN COUNTERSPACE. 210-52-C1 | | | | 5)NOTE: PLEASE SEE MISSING HALL RECEPT | | 210-52H | | | | 6)NOTE: PLEASE SEE PANEL SCHEDULE, SHOWS | | TWO CIRCUITS FOR SM APPL AND SHOWS LOAD | | FOR THREE? PLEASE CORRELATE. | | | | 7)NOTE: PLEASE CORRELATE SUB PANEL | | WITH MLO SHOWNAT 65A'S, MAIN PANEL | | SHOWS AT 60A. | | | | 8)NOTE: PLEASE SHOW ROOM DESIGNATIONS | | ON FLOOR LAYOUT. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2003-10-22 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-22 |
Time |
12:16 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-10-22 |
Time |
12:16 |
Sent To |
M |
|
Notes |
2003-10-22 00:00:00 | TO PK BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-06-27 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-06-27 |
Time |
15:37 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-06-27 |
Time |
15:37 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-04-02 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-02 |
Time |
14:59 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-04-02 |
Time |
14:59 |
Sent To |
E |
|
Notes |
2003-04-02 00:00:00 | DPALMER DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-02-21 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-02-21 |
Time |
13:45 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2003-02-21 |
Time |
13:45 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2003-10-22 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2003-10-22 |
Time |
18:18 |
Rev Time |
0.50 |
Received By |
hmoser |
Date |
2003-10-22 |
Time |
18:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-03-15 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-22 |
Time |
12:17 |
Rev Time |
0.50 |
Received By |
hmoser |
Date |
2003-03-15 |
Time |
09:39 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2003-03-12 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-03-12 |
Time |
14:35 |
Rev Time |
0.25 |
Received By |
jleech |
Date |
2003-03-12 |
Time |
17:17 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-02-25 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-02-21 |
Time |
13:45 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
P |
|
Notes |
|
|