Plan Review Stops For Permit 03021468 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2003-03-24 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-03-10 |
Time |
07:17 |
Rev Time |
2.00 |
Received By |
jgomez |
Date |
2003-03-24 |
Time |
16:03 |
Sent To |
|
|
Notes |
2003-03-24 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | 1-PROVIDE COMPLETE INFORMATION FOR STORM | | SHUTTERS UNDER A SEPARATE PERMIT. | | 2-ENERGY CALCULATIONS TO HAVE ORIGINAL | | SIGNATURE AS REQUIRED BY CHAPTER 471 | | FLORIDA STATUTES AND SECTION 103.0 OF | | CHAPTER 13 FBC 2001. | | 3-CLARIFY DETAIL S21 FOR COLUMN LOCATED | | BETWEEN GARAGE AND STAIRWAY. HOW ARE | | TRUSSES SUPPORTED BY THE STRAPS?. SEC. | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | 4-REVISE/CLARIFY SIZE OF EGRESS WINDOWS. | | 34SH WINDOW DOESN'T PROVIDE THE 24" | | MIN. CLEAR HEIGHT. ALSO, CHECK THAT | | 24+5 SH WINDOWS PROVIDE THE 5.7S.F. | | MIN. CLEAR OPENING AS REQUIRED BY | | SECTION 1005.4.4 FBC 2001. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2003-08-19 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-08-19 |
Time |
10:42 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2003-08-19 |
Time |
10:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2003-08-11 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-13 |
Time |
09:43 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2003-08-11 |
Time |
12:33 |
Sent To |
|
|
Notes |
2003-08-11 00:00:00 | *************** UNSAT *************** | | | | 1)NOTE: PLEASE MAKE SURE BOTH SETS ARE | | SIGNED WITH ORIGINAL SIGNATURE AS REQ`D | | UNDER FAC 61G1-16.004, FS 481.221 | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2003-03-10 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-06 |
Time |
09:50 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2003-03-10 |
Time |
07:17 |
Sent To |
B |
|
Notes |
2003-03-10 00:00:00 | ********** NOTES REDLINED.********* | | | | PANEL SCHEDULE AND RISER DIAGRAM TO | | CORRELATE. PANEL SHOWS 2P-40/#10 FOR | | 60A SUB PANEL. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2003-08-13 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-13 |
Time |
09:39 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-08-13 |
Time |
09:39 |
Sent To |
E |
|
Notes |
2003-08-13 00:00:00 | TO DPALMER DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-08-06 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-06 |
Time |
09:49 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-08-06 |
Time |
09:48 |
Sent To |
E |
|
Notes |
2003-08-06 00:00:00 | TO DP DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-08-01 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-01 |
Time |
15:08 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-08-01 |
Time |
15:08 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-02-21 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-02-21 |
Time |
15:49 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2003-02-21 |
Time |
15:49 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2003-08-14 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-08-14 |
Time |
14:46 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2003-08-14 |
Time |
14:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-03-04 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-01 |
Time |
15:08 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2003-03-04 |
Time |
18:51 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2003-03-04 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2003-02-25 |
Time |
11:28 |
Rev Time |
0.25 |
Received By |
jleech |
Date |
2003-03-04 |
Time |
18:50 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-02-25 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-02-21 |
Time |
15:49 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
P |
|
Notes |
|
|