Plan Review Details - Permit 03021468
Plan Review Stops For Permit 03021468
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-03-24 Cont ID  
Sent By dpalmer Date 2003-03-10 Time 07:17 Rev Time 2.00
Received By jgomez Date 2003-03-24 Time 16:03 Sent To  
Notes
2003-03-24 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS UNDER A SEPARATE PERMIT.
 2-ENERGY CALCULATIONS TO HAVE ORIGINAL
 SIGNATURE AS REQUIRED BY CHAPTER 471
 FLORIDA STATUTES AND SECTION 103.0 OF
 CHAPTER 13 FBC 2001.
 3-CLARIFY DETAIL S21 FOR COLUMN LOCATED
 BETWEEN GARAGE AND STAIRWAY. HOW ARE
 TRUSSES SUPPORTED BY THE STRAPS?. SEC.
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 4-REVISE/CLARIFY SIZE OF EGRESS WINDOWS.
 34SH WINDOW DOESN'T PROVIDE THE 24"
 MIN. CLEAR HEIGHT. ALSO, CHECK THAT
 24+5 SH WINDOWS PROVIDE THE 5.7S.F.
 MIN. CLEAR OPENING AS REQUIRED BY
 SECTION 1005.4.4 FBC 2001.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-08-19 Cont ID  
Sent By dpalmer Date 2003-08-19 Time 10:42 Rev Time 0.25
Received By dpalmer Date 2003-08-19 Time 10:42 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2003-08-11 Cont ID  
Sent By alange Date 2003-08-13 Time 09:43 Rev Time 0.25
Received By dpalmer Date 2003-08-11 Time 12:33 Sent To  
Notes
2003-08-11 00:00:00*************** UNSAT ***************
  
 1)NOTE: PLEASE MAKE SURE BOTH SETS ARE
 SIGNED WITH ORIGINAL SIGNATURE AS REQ`D
 UNDER FAC 61G1-16.004, FS 481.221
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-03-10 Cont ID  
Sent By alange Date 2003-08-06 Time 09:50 Rev Time 0.25
Received By dpalmer Date 2003-03-10 Time 07:17 Sent To B
Notes
2003-03-10 00:00:00********** NOTES REDLINED.*********
  
 PANEL SCHEDULE AND RISER DIAGRAM TO
 CORRELATE. PANEL SHOWS 2P-40/#10 FOR
 60A SUB PANEL.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-08-13 Cont ID  
Sent By alange Date 2003-08-13 Time 09:39 Rev Time 0.00
Received By alange Date 2003-08-13 Time 09:39 Sent To E
Notes
2003-08-13 00:00:00TO DPALMER DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-08-06 Cont ID  
Sent By alange Date 2003-08-06 Time 09:49 Rev Time 0.00
Received By alange Date 2003-08-06 Time 09:48 Sent To E
Notes
2003-08-06 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-08-01 Cont ID  
Sent By alange Date 2003-08-01 Time 15:08 Rev Time 0.00
Received By alange Date 2003-08-01 Time 15:08 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-02-21 Cont ID  
Sent By dpalmer Date 2003-02-21 Time 15:49 Rev Time 0.00
Received By dpalmer Date 2003-02-21 Time 15:49 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-08-14 Cont ID  
Sent By pkrauss Date 2003-08-14 Time 14:46 Rev Time 0.25
Received By pkrauss Date 2003-08-14 Time 14:46 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-03-04 Cont ID  
Sent By alange Date 2003-08-01 Time 15:08 Rev Time 0.33
Received By jleech Date 2003-03-04 Time 18:51 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-03-04 Cont ID  
Sent By sgraham Date 2003-02-25 Time 11:28 Rev Time 0.25
Received By jleech Date 2003-03-04 Time 18:50 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-02-25 Cont ID  
Sent By dpalmer Date 2003-02-21 Time 15:49 Rev Time 0.00
Received By sgraham Date   Time   Sent To P
Notes
***NONE***