Plan Review Details - Permit 03021220
Plan Review Stops For Permit 03021220
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-03-21 Cont ID  
Sent By dpalmer Date 2003-03-21 Time 07:10 Rev Time 0.00
Received By nleiva Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-07-24 Cont ID  
Sent By btrobaug Date 2003-07-24 Time 09:28 Rev Time 0.50
Received By btrobaug Date 2003-07-24 Time 07:53 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-03-21 Cont ID  
Sent By alange Date 2003-07-22 Time 15:24 Rev Time 0.33
Received By dpalmer Date 2003-03-21 Time 07:10 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-03-07 Cont ID  
Sent By sthyng Date 2003-03-18 Time 16:51 Rev Time 0.33
Received By dpalmer Date 2003-03-07 Time 07:28 Sent To B
Notes
2003-03-07 00:00:00**************** UNSAT *****************
  
 1)NOTE: PLEASE SUBMIT PANEL SCHEDULE
 FOR MAIN PANEL. SHOWS ITEMS BEING FED
 W/OUT ANY LISTINGS
  
 2)NOTE: PLEASE CORRELATE OCP/AWG/KW
 FOR AHU #2. SHOWS #10, 2P25AOCP W/ A
 10KW LOAD?
  
 3)NOTE: PLEASE SEE LOAD CALCUALTIONS,
 SHOWS 4 SM APPL, WASHER + 6KW. PLEASE
 SEE LOAD @ 1500EACH SHOULD = 7500W.
  
 4)NOTE: PLEASE ALSO SEE 4- SM APPL
 LISTED IN LOAD CALCS AND ONLY 2 SHOWN
 ON PANEL SCHEDULE.
  
 5)NOTE: PLEASE SEE MISSING RECEPT IN
 BR #4.210-52
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-07-22 Cont ID  
Sent By alange Date 2003-07-22 Time 15:24 Rev Time 0.00
Received By alange Date 2003-07-22 Time 15:24 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-03-18 Cont ID  
Sent By sthyng Date 2003-03-18 Time 16:51 Rev Time 0.00
Received By sthyng Date 2003-03-18 Time 16:51 Sent To E
Notes
2003-03-18 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-02-19 Cont ID  
Sent By dpalmer Date 2003-02-19 Time 15:32 Rev Time 0.00
Received By dpalmer Date 2003-02-19 Time 15:32 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-03-03 Cont ID  
Sent By jleech Date 2003-03-03 Time 17:35 Rev Time 0.33
Received By jleech Date 2003-03-03 Time 17:35 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-03-03 Cont ID  
Sent By sgraham Date 2003-02-25 Time 11:32 Rev Time 0.33
Received By jleech Date 2003-03-03 Time 17:34 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-02-25 Cont ID  
Sent By dpalmer Date 2003-02-19 Time 15:32 Rev Time 0.00
Received By sgraham Date   Time   Sent To P
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved