Plan Review Details - Permit 03020552
Plan Review Stops For Permit 03020552
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-03-04 Cont ID  
Sent By dpalmer Date 2003-03-03 Time 16:55 Rev Time 0.50
Received By sthyng Date 2003-03-04 Time 11:05 Sent To  
Notes
2003-03-04 00:00:00PASSED AS PER LS - ST

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-03-03 Cont ID  
Sent By kstevens Date 2003-02-28 Time 12:23 Rev Time 0.25
Received By dpalmer Date 2003-03-03 Time 16:54 Sent To B
Notes
2003-03-03 00:00:00NOTED ON PLANS, BATTERY POOL ALARMS NOT
 PERMITTED UNDER FBC.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-03-19 Cont ID  
Sent By sthyng Date 2003-03-19 Time 13:46 Rev Time 0.00
Received By sthyng Date 2003-03-19 Time 13:46 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-02-10 Cont ID  
Sent By dpalmer Date 2003-02-10 Time 10:39 Rev Time 0.00
Received By dpalmer Date 2003-02-10 Time 10:39 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-03-24 Cont ID  
Sent By kstevens Date 2003-03-24 Time 14:05 Rev Time 0.33
Received By kstevens Date 2003-03-24 Time 14:05 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-02-28 Cont ID  
Sent By sthyng Date 2003-03-19 Time 13:46 Rev Time 0.50
Received By kstevens Date 2003-02-28 Time 12:23 Sent To E
Notes
2003-02-28 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) COMPLY WITH FBC-2001 SEC 424.2
 PRIVATE SWIMMING POOLS.
 2) FBC-2001 SEC 424.2.6.1 ENGINEERING
 DESIGN, CONSTRUCTION AND WORKMANSHIP.
 ANSI/NSPI-4 92, AND NSPI-5. (ADD TO
 NOTES)
 3) FBC-2001424.2.6.6.2 SHOW COMPLIANCE
 WITH ANSI/ASME A112.19.8M. PROVIDE MODEL
 NUMBER AND MANUF INFO FOR VAC LOCK.
 (GIVE DETAIL OR ADD NOTE)(SUBMITTAL)
 4) FBC-2001424.2.6.6.5 WHERE PROVIDED,
 THE VACUUM OR PRESSURE CLEANER FITTING
 SHALL BE LOCATED AT LEAST 6" AND NOT
 GREATER THAN 12" BELOW THE MINIMUM OPER-
 ATING WATER LEVEL OR AS AN ATTACHMENT TO
 THE SKIMMER.
 5) FBC-2001 424.2.9 WATER SUPPLY, LOCAL
 ORD. #2853-95, BACKFLOW REQUIRED ON
 WATER SERVICE. (ADD TO NOTES)
 6) FBC-2001 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 7) FBC-2001 424.2.13.2JOINTS AND CON-
 NECTIONS, FBC PLMG SEC 605.21, PURPLE
 PRIMER REQUIRED ON PVC PIPING. (ADD TO
 NOTES)
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2003-02-11 Cont ID  
Sent By dpalmer Date 2003-02-10 Time 10:39 Rev Time 0.00
Received By sgraham Date   Time   Sent To P
Notes
***NONE***