Plan Review Details - Permit 03020543
Plan Review Stops For Permit 03020543
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-02-28 Cont ID  
Sent By dpalmer Date 2003-02-24 Time 06:45 Rev Time 2.00
Received By jgomez Date 2003-02-28 Time 10:35 Sent To  
Notes
2003-02-28 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS UNDER A SEPARATE PERMIT.
 2-FLOOD ZONE A8: NEED TO PROVIDE THE
 ELEVATION CERTIFICATE.
 3-SHEET A-1: REVISE NOTE #24. SEE SEC.
 1007.5.1 FBC 2001 FOR HANDRAIL HEIGHT.
 4-GLASS BLOCK TO BE SAFETY GLASS IF FACE
 THICKNESS IS LESS THAN 0.25". SECTION
 2405.2.2 FBC 2001.
 5-SHEET A-4: REVISE NOTE #1. SEE SECTION
 1007.5.1 FBC 2001 FOR HANDRAIL HEIGHT.
 6-PROVIDE GENERAL SPECS FOR FIREBLOCKING
 AT ALL CONCEALED SPACES. SEC. 2305.1.4
 FBC 2001.
 7-PROVIDE COMPLETE DETAIL/SECTION FOR
 TOP CONNECTION OF WOOD COLUMN LOCATED
 BETWEEN GARAGE AND KITCHEN. CLARIFY
 HOW ARE GIRDER TRUSSES ATTACHED TO
 COLUMN WITH THE STRAPS. SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 8-SHEET S3: PROVIDE SPECS ON STRUCTURAL
 WALL SECTIONS FOR FIRECUT REQUIREMENTS
 SEC. 2305.4 FBC 2001.
 9-GARAGE DOOR STRUCTURAL BUCK DETAIL:
 SPECIFY ANCHOR EMBEDMENT AND WASHER
 SIZE. SEC. 104.2.1.2 CITY AMENDMENTS
 TO FBC 2001.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-02-24 Cont ID  
Sent By jleech Date 2003-02-22 Time 09:11 Rev Time 0.25
Received By dpalmer Date 2003-02-24 Time 06:45 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-07-01 Cont ID  
Sent By shernand Date 2003-07-01 Time 12:50 Rev Time 0.00
Received By shernand Date 2003-07-01 Time 12:50 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-02-10 Cont ID  
Sent By dpalmer Date 2003-02-10 Time 11:55 Rev Time 0.00
Received By dpalmer Date 2003-02-10 Time 11:55 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-07-03 Cont ID  
Sent By pkrauss Date 2003-07-03 Time 14:38 Rev Time 0.25
Received By pkrauss Date 2003-07-03 Time 14:38 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-02-22 Cont ID  
Sent By shernand Date 2003-07-01 Time 12:50 Rev Time 0.33
Received By jleech Date 2003-02-22 Time 09:11 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-02-22 Cont ID  
Sent By sgraham Date 2003-02-19 Time 12:50 Rev Time 0.33
Received By jleech Date 2003-02-22 Time 09:10 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-02-19 Cont ID  
Sent By dpalmer Date 2003-02-10 Time 11:55 Rev Time 0.00
Received By sgraham Date   Time   Sent To P
Notes
***NONE***