Plan Review Stops For Permit 03020498 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2003-03-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2003-03-07 |
Time |
16:11 |
Rev Time |
2.00 |
Received By |
jgomez |
Date |
2003-03-07 |
Time |
16:11 |
Sent To |
|
|
Notes |
2003-03-07 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | 1-PROVIDE COMPLETE INFORMATION FOR STORM | | SHUTTERS UNDER A SEPARATE PERMIT. | | 2-PROVIDE ENERGY CALCULATIONS WITH | | ORIGINAL ENGINEER'S SEAL & SIGNATURE | | AS REQUIRED BY CHAPTER 471 FLORIDA | | STATUTES WHEN SUBMITTING INFORMATION | | FOR PUBLIC RECORDS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2003-03-04 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2003-03-04 |
Time |
15:08 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2003-03-04 |
Time |
15:08 |
Sent To |
|
|
Notes |
2003-03-04 00:00:00 | SECOND CHECKLIST: | | 1-AREA CALCULATIONS WERE NOT CHANGED ON | | SHEETS C-1 AND A-1 AS REQUESTED ON | | FIRST CHECKLIST. | | **NOTE: ARCHITECT NEEDS TO REVISE AREA | | CALCULATIONS ACCORDINGLY WHEN HAVING | | THE BONUS ROOM OPTION. | | 2-PROVIDE COMPLETE INFORMATION FOR STORM | | SHUTTERS OR APPLY FOR SEPARATE PERMIT. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-02-14 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-03-03 |
Time |
08:17 |
Rev Time |
1.50 |
Received By |
jgomez |
Date |
2003-02-14 |
Time |
14:22 |
Sent To |
|
|
Notes |
2003-02-14 00:00:00 | BUILDING REVIEW CHECKLIST: | | 1-AREA CALCULATIONS ARE INCORRECT REVISE | | SHEET C-1 AND A-1 AS REQUIRED. | | 2-PROVIDE COMPLETE INFORMATION FOR STORM | | SHUTTERS OR APPLY FOR SEPARATE PERMIT. | | 3-NEED RECORDED NOTICE OF COMMENCEMENT. | | 4-GARAGE DOOR STRUCTURAL BUCK DETAIL: | | SPECIFY ANCHOR EMBEDMENT AND WASHER | | SIZE. SEC. 104.2.1.2 CITY AMENDMENTS | | TO FBC. | | 5-BUILDING SECTION A/A-5: REVISE HEIGHT | | OF HANDRAIL. SEE SEC. 1007.5.1 FBC. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2003-02-14 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-02-14 |
Time |
09:38 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2003-02-14 |
Time |
09:42 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-03-12 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-03-12 |
Time |
15:30 |
Rev Time |
0.00 |
Received By |
sthyng |
Date |
2003-03-12 |
Time |
15:29 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-02-26 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-02-26 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2003-02-26 |
Time |
10:22 |
Sent To |
M |
|
Notes |
2003-02-26 00:00:00 | TO MECH INBOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2003-06-02 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-06-02 |
Time |
13:03 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2003-06-02 |
Time |
13:03 |
Sent To |
|
|
Notes |
2003-06-02 00:00:00 | MECH REV PERMIT 03020589 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2003-03-03 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-03-03 |
Time |
08:17 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2003-03-03 |
Time |
08:11 |
Sent To |
B |
|
Notes |
2003-03-03 00:00:00 | MECHANICAL PERMIT 03020589 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2003-02-14 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-02-26 |
Time |
10:23 |
Rev Time |
0.40 |
Received By |
pkrauss |
Date |
2003-02-14 |
Time |
08:31 |
Sent To |
E |
|
Notes |
2003-02-14 00:00:00 | DENIED:MECHANICAL PERMIT 03020589 | | | | 1.APPLIANCES IN GARAGE SHALL HAVE | | PROTECTION FROM DAMAGE AS PER 2001 | | FBC(M) 303.4. | | | | 2.SEER ON ENERGY CALCS INDICATE AN | | 11 SEER & EQUIPMENT SCHEDULE SHOWS A | | 10 SEER.PLEASE CORRECT. | | | | 3.AUXILIARY DRAIN PAN SHALL HAVE | | A FLOAT SWITCH OR SECONDARY DRAIN AS | | PER 2001 FBC(M)307.2.3. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT 659-8096 | | EXT. 8388. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2003-02-11 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-03-12 |
Time |
15:30 |
Rev Time |
0.25 |
Received By |
kstevens |
Date |
2003-02-11 |
Time |
10:32 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-02-07 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2003-02-07 |
Time |
16:11 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
P |
|
Notes |
|
|