Plan Review Details - Permit 03020319
Plan Review Stops For Permit 03020319
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2003-05-06 Cont ID  
Sent By jgomez Date 2003-05-06 Time 17:31 Rev Time 0.50
Received By jgomez Date 2003-05-06 Time 17:31 Sent To  
Notes
2003-05-06 00:00:00STORM SHUTTERS, HANDRAIL CLARIFICATION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-04-15 Cont ID  
Sent By shernand Date 2003-05-05 Time 14:06 Rev Time 1.00
Received By jgomez Date 2003-04-15 Time 16:03 Sent To  
Notes
2003-04-15 00:00:00ENERGY CALCULATIONS AND SOIL TEST REPORT
 SUBMITTED. SEE PROVISO DATED 4-2-03 FOR
 OUTSTANDING ITEMS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-04-02 Cont ID  
Sent By jgomez Date 2003-04-02 Time 15:46 Rev Time 2.00
Received By jgomez Date 2003-04-02 Time 15:46 Sent To E
Notes
2003-04-02 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-ENERGY CALCULATIONS TO HAVE ENGINEER'S
 ORIGINAL SEAL AND SIGNATURE AS REQ'D
 BY CHAPTER 471 FLORIDA STATUTES WHEN
 SUBMITTING DOCUMENTS FOR PUBLIC RECORD
 2-PROVIDE SOIL TEST REPORT WITH ORIGINAL
 SIGNATURE AND SEAL. CHAPTER 471 FL.ST.
 3-STORM SHUTTERS: SEE ENGINEERED DWGS
 AND REVISE INSTALLATION SCHEDULE AS
 REQUIRED. CHECK DESIGN PRESSURES,
 PANEL MAX. SPAN, ANCHOR TYPE & SPACING
 AND MOUNTING CONDITIONS AND CONNECTION
 TYPE.
 4-SHEET A-4: SEE STAIR SECTION B/A-4 AND
 CLARIFY NOTES #1 AND #8. SEE SECTION
 1007.5.1 FBC 2001.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-02-24 Cont ID  
Sent By pkrauss Date 2003-04-01 Time 11:51 Rev Time 2.00
Received By jgomez Date 2003-02-24 Time 14:25 Sent To  
Notes
2003-02-24 00:00:00BUILDING REVIEW CHECKLIST:
 1-FLOOD ZONE A8. WILL NEED TO PROVIDE
 THE ELEVATION CERTIFICATE.
 2-NEED RECORDED NOTICE OF COMMENCEMENT.
 3-SHEET A-4: REVISE STAIR KEY NOTE #1.
 SEE SECTION 1007.5.1 FBC 2001 FOR
 REQUIRED HANDRAIL HEIGHT.
 **ALSO, REVISE HANDRAIL HEIGHT SHOWN ON
 STAIR SECTION B/A-4.
 4-SHEET A-4: SPECIFY FIREBLOCKING
 MATERIAL AND LOCATION. SEE SECTION
 2305.1.4 FBC 2001.
 **NOTE: FIREBLOCKING AND DRAFSTOPPING
 ARE NOT THE SAME THING. REVISE NOTE
 #14 AS REQUIRED.
 5-PROVIDE GENERAL SPECS FOR FIREBLOCKING
 AT ALL CONCEALED SPACES. SEE SECTION
 2305.1.4 FBC 2001.
 6-SHEET A-5: SIZE OF VENT ON NOTE #14
 DOESN'T MATCH VENTILATION CALCULATIONS
 REVISE AS REQUIRED.
 7-CLARIFY SIZE OF BUCKET SHOWN ON DETAIL
 S6. SEE GIRDER TRUSS SIZE. SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 8-DETAIL S21 DOESN'T MATCH CONDITIONS
 SHOWN ON SECOND FLOOR FRAMING PLAN.
 REVISE AS REQUIRED. SEC. 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
 9-SHOW NAILING ZONES IN ROOF FRAMING
 PLAN. SEE SEC. 2306.1 CITY AMENDMENTS
 TO FBC 2001.
 10-REVISE/UPDATE TRUSS ANCHOR SCHEDULE
 TO MATCH USP PUBLISHED CATALOGUE. SEC.
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 11-PROVIDE FIRECUT SPECIFICATIONS ON
 STRUCTURAL WALL SECTIONS. SECTION
 2305.4 FBC 2001.
 12-DETAIL SECTION S2 HAS OVERLAPPING
 INFORMATION. REVISE AS REQUIRED.
 13-DETAIL F14: SPECIFY HOW MUCH EMBED-
 MENT FOR ANCHOR BOLTS. SEC. 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
 14-PROVIDE 2X STRUCTURAL BUCK DETAIL FOR
 FRAMED OPENINGS TO RECEIVED ARCHED
 WINDOWS. SEC. 104.2.1.2 CITY AMENDMENT
 TO FBC 2001.
 15-PROVIDE COMPLETE INFORMATION FOR
 STORM SHUTTERS OR APPLY FOR A SEPARATE
 PERMIT.
 16-SECOND FLOOR FRAMING PLAN IS MISSING
 SOME CONNECTORS. EG. SPECIFY CONNECTOR
 FOR GIRDER TRUSSES. SEE PLANS FOR
 COMMENTS. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-09-25 Cont ID  
Sent By btrobaug Date 2003-09-25 Time 16:26 Rev Time 0.33
Received By btrobaug Date 2003-09-25 Time 16:16 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-04-03 Cont ID  
Sent By csiegber Date 2003-09-19 Time 12:17 Rev Time 0.25
Received By dpalmer Date 2003-04-03 Time 12:41 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-02-20 Cont ID  
Sent By jgomez Date 2003-04-02 Time 15:46 Rev Time 0.25
Received By dpalmer Date 2003-02-20 Time 18:43 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2003-09-25 Cont ID  
Sent By csiegber Date 2003-09-25 Time 09:46 Rev Time 0.00
Received By csiegber Date 2003-09-25 Time 09:45 Sent To M
Notes
2003-09-25 00:00:00TO PK BOX

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-09-19 Cont ID  
Sent By csiegber Date 2003-09-19 Time 12:17 Rev Time 0.00
Received By csiegber Date 2003-09-19 Time 12:17 Sent To E
Notes
2003-09-19 00:00:00TO BT DESK

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-05-08 Cont ID  
Sent By shernand Date 2003-05-08 Time 13:40 Rev Time 0.00
Received By shernand Date 2003-05-08 Time 13:40 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-05-05 Cont ID  
Sent By shernand Date 2003-05-05 Time 14:06 Rev Time 0.00
Received By shernand Date 2003-05-05 Time 14:06 Sent To B
Notes
2003-05-05 00:00:00JGOMEZ DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-03-27 Cont ID  
Sent By sthyng Date 2003-03-27 Time 08:13 Rev Time 0.00
Received By sthyng Date 2003-03-27 Time 08:13 Sent To M
Notes
2003-03-27 00:00:00TO MECH IN BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-02-06 Cont ID  
Sent By dpalmer Date 2003-02-06 Time 12:44 Rev Time 0.00
Received By dpalmer Date 2003-02-06 Time 12:44 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-09-30 Cont ID  
Sent By pkrauss Date 2003-09-30 Time 07:53 Rev Time 0.20
Received By pkrauss Date 2003-09-30 Time 07:53 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-04-01 Cont ID  
Sent By csiegber Date 2003-09-25 Time 09:46 Rev Time 0.35
Received By pkrauss Date 2003-04-01 Time 11:21 Sent To B
Notes
2003-04-01 00:00:00MECHANICAL PERMIT 03020323

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-02-19 Cont ID  
Sent By sthyng Date 2003-03-27 Time 08:13 Rev Time 0.25
Received By hmoser Date 2003-02-19 Time 19:27 Sent To E
Notes
2003-02-19 00:00:00PLAN DENIED
 1) ENERGY PERFORMANCE LEVEL DISPLAY CARD
 AND ENERGY CALCULATIONS DO NOT MATCH.
 2) EQUIPMENT SELESTION ON MANUAL (J) NOT
 COMPLETE.
 3) COOLING & HEATING BTU.ON MANUAL (J)
 DO NOTMATCH PLANS.
 PLAN REVIEW BY HAROLD MOSER
 (561)689-8096 EXT.8390

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-05-20 Cont ID  
Sent By kstevens Date 2003-05-20 Time 07:09 Rev Time 0.33
Received By kstevens Date 2003-05-19 Time 18:53 Sent To  
Notes
2003-05-20 00:00:00REVISION OK - ADDED SANT. RISER DIAGRAM

Review Stop P PLUMBING
Rev No 1 Status N Date 2003-02-10 Cont ID  
Sent By shernand Date 2003-05-08 Time 13:40 Rev Time 0.33
Received By kstevens Date 2003-02-10 Time 12:26 Sent To M
Notes
2003-02-10 00:00:00COVER SHEET INDEX CALLS FOR AN MP-1
 SHEET AND AN MP-2 SHEET BUT NOTE THAT
 NONE WERE FOUND.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2003-02-06 Cont ID  
Sent By dpalmer Date 2003-02-06 Time 12:44 Rev Time 0.00
Received By sgraham Date   Time   Sent To P
Notes
***NONE***