Plan Review Details - Permit 03012327
Plan Review Stops For Permit 03012327
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-03-17 Cont ID  
Sent By sthyng Date 2003-03-17 Time 13:31 Rev Time 0.00
Received By sthyng Date 2003-03-17 Time 13:31 Sent To  
Notes
2003-03-17 00:00:00**********CORRECTIONS************
  
 1.)2001 FL BLD CODE, 1005.4:
 PROVIDE EMERGENCY EGRESS WINDOWS IN
 SLEEPING ROOMS WITH A MINIMUM NET CLEAR
 OPENING HEIGTH OF 24" AND NET CLEAR
 OPENING WIDTH OF 20" AND A NET CLEAR
 OPENING AREA OF 5.7 SQ.FT. GROUND FLOOR
 OPENINGS ARE PERMITTED TO HAVE A NET
 CLEAR OPENING OF 5.0 SQ. FT. SILL HEIGTH
 SHALL NOT BE MORE THAN 44 " ABOVE THE
 FINISH FLOOR.
  
 2.)PLEASE NOTE ITEM #3 ON THE FIRST
 CORRECTION NOTICE.AS PER FBC3401.7.2.4
 THE REPLACEMENT OF OPERATIVE AND
 INOPERATIVE WINDOWS SHALL BE DESIGNED
 AND CONSTRUCTED IN ACCORDANCE WITH
 CHAPTER 16 OF THE FBC.HURRICANE
 PROTECTION REQUIRED.
  
 3.)PLEASE SUBMIT TWO COPIES OF ALL
 DOCUMENTATION.ONLY ONE COPY OF THE
 REVISED WINDOW SCHEDULE AND PRODUCT
 APPROVALS WAS SUBMITTED.
  
 4.)PROVIDE PRODUCT APPROVALS FOR THE
 PICTURE WINDOW FOR WINDOW #4.PRODUCT
 APPROVALS PREVIOUSLY SUBMITTED WERE FOR
 NORANDEX SINGLE HUNG AND NORANDEX
 FIXED WINDOW.LEGIBLE PRODUCT APPROVALS
 WERE REQUESTED (NOTE COMMENT #1 OF
 FIRST CORRECTION LIST).PGT SINGLE
 HUNG AND PGT MULLION PRODUCT APPROVALS
 WERE SUBMITTED.
  
 5.)A HOLD WAS PLACED ON THIS PROPERTY
 BY E.GARCED.PLEASE CONTACT MR. GARCED
 AT 659-8000, EXTENSION 8467.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 561-659-8096, EXTENSION 8340

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-02-12 Cont ID  
Sent By sthyng Date 2003-03-11 Time 15:58 Rev Time 1.00
Received By sthyng Date 2003-02-12 Time 10:21 Sent To  
Notes
2003-02-12 00:00:00**********CORRECTIONS************
  
 1.)PLEASE PROVIDE LEGIBLE PRODUCT
 APPROVALS FOR THE S/H WINDOWS.PLEASE
 CIRCLE ATTACHMENT DETAILS SPECIFIC TO
 THE JOB ON ALL PRODUCT APPROVALS.
  
 2.)PROVIDE BEDROOM LOCATIONS ON THE
 FLOOR PLAN WHERE WINDOWS ARE BEING
 REPLACED.
  
 3.)HURRICANE PROTECTION IS REQUIRED
 FOR WINDOW REPLACEMENT.IF A PRODUCT
 APPROVAL FOR HURRICANE SHUTTERS IS
 SUBMITTED, PLEASE CIRCLE THE SPECIFIC
 ATTACHMENT DETAILS FOR THIS JOB.
  
 4.)PROVIDE PRODUCT APPROVALS FOR
 MULLS FOR WINDOW OPENING #4 IF THREE
 WINDOWS ARE BEING MULLED TOGETHER
 AS INDICATED ON THE FLOOR PLAN.
  
 5.)OWNER NAME ON PERMIT APPLICATION
 (VALERIE MAYS JOHNSON) DOES NOT MATCH
 PROPERTY RECORDS (BETTY JW MAYS).
 PLEASE EITHER PROVIDE PROOF OF OWNERSHIP
 OR REVISE THE PERMIT APPLICATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 LEA SMITH OR SAMANTHA THYNG
 561-659-8096, EXTENSION 8340

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-03-11 Cont ID  
Sent By sthyng Date 2003-03-11 Time 15:58 Rev Time 0.00
Received By sthyng Date 2003-03-11 Time 15:57 Sent To B
Notes
2003-03-11 00:00:00SENT TO ST DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-01-30 Cont ID  
Sent By btrobaug Date 2003-01-30 Time 13:04 Rev Time 0.00
Received By btrobaug Date 2003-01-30 Time 13:04 Sent To Z
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status   Date   Cont ID  
Sent By btrobaug Date 2003-01-30 Time 13:04 Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***