Plan Review Details - Permit 03012111
Plan Review Stops For Permit 03012111
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-03-13 Cont ID  
Sent By shernand Date 2003-04-02 Time 15:53 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
2003-03-13 00:00:00PROVISO
  
 SUBMIT A REVISED STORM PANEL
 INSTALLATION SCHEDULE WITH THE CORRECTED
 OPENING SIZES.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-03-06 Cont ID  
Sent By sthyng Date 2003-03-12 Time 16:44 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
2003-03-06 00:00:00DENIED
  
 1) THE SITE SPECIFIC PRODUCT APPROVALS
 FOR THE NORANDEX PRODUCTS ARE REQUIRED
 BY THE BUILDING OFFICIAL TO HAVE THE
 EMBOSSED SEAL OF THE DESIGNER OF RECORD
 FOR THE STRUCTURE AND THE LOCATION OF
 THE JOB ON THE FORM.
  
 2) THE R VALUES LISTED ON THE ENERGY
 CALCULATIONS FOR THE EXTERIOR AND
 ADJACENT WALLS ARE REVERSED. PLEASE
 CORRECT.
  
 3) THE OPENING SIZES ON THE STORM PANEL
 SCHEDULE ARE INCORRECT FOR OPENINGS 4
 AND 10.
  
 4) THERE ARE NO PRODUCT APPROVALS FOR
 THE STORM PANELS IN THE PACKAGE.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-02-11 Cont ID  
Sent By dpalmer Date 2003-03-05 Time 10:47 Rev Time 0.00
Received By rmcdouga Date 2003-03-06 Time 12:39 Sent To M
Notes
2003-02-11 00:00:00BUILDING DENIED
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) THE SURVEY HAS THE WRONG LOMR CASE
 NUMBER AND DATE FOR THE FLOOD ZONE
 INFORMATION. PLEASE CORRECT.
  
 3) SPECIFY ON THE PLANS THAT THE WIRE
 MESH IN THE SLAB WILL BE SUPPORTED AT
 THREE FEET ON CENTER AS REQUIRED BY FBC
 1909.3.
  
 4) THE WINDOW IN BATH #2 IS REQUIRED TO
 HAVE SAFETY GLAZING BECAUSE IT IS WITHIN
 3 FEET HORIZONTALLY OF THE TUB/SHOWER.
 THIS IS NOT CLEARLY INDICATED BY GENERAL
 NOTE #9 ON SHEET 1. PLEASE REVISE. SEE
 FBC 2405.2.1.
  
 5) SPECIFY THE SIZE OF THE ATTIC ACCESS.
 SEE FBC 2309.6.
  
 6) SPECIFY THE LENGTH/EMBED DEPTH OF THE
 5/8" EXPANISION BOLTS FOR THE GARAGE
 DOOR BUCKS ON THE DETAIL ON SHEET 4.
  
 7) THE GABLE END AT THE REAR AND
 ADJACENT TO THE VAULTED CEILING IS
 REQUIRED TO BE CONTINOUS FROM THE FLOOR
 TO THE CEILING DIAPHRAM PER FBC 1918.3.2
 PLEASE PROVIDE A DETAIL OF THIS AREA
 INCLUDING THE RAKE BEAM.
  
 8) THE SITE SPECIFIC ENGINEERING FOR THE
 NORANDEX PRODUCTS ARE REQUIRED TO HAVE
 THE EMBOSSED SEAL OF THE DESIGNER OF
 RECORD FOR THE STRUCTURE AND THE
 LOCATION OF THE JOB ON THE FORM.
  
 9) THE R-VALUES GIVEN FOR THE INSULATION
 AT THE CONCRETE EXTERIOR WALLS AND THE
 WOOD FRAME ADJACENT WALLS ON THE ENERGY
 CALCS. ARE REVERSED. PLEASE CORRECT.
  
 10) THE OPENING SIZES LISTED ON THE
 STORM PANEL INSTALLATION SCHEDULE ARE
 INCORRECT FOR NUMBERS 4 AND 10. PLEASE
 CORRECT.
  
 11) SPECIFY THE SIZE OF THE FIXED GLASS
 TRANSOM ABOVE THE FRONT DOOR ON THE
 PLANS.
  
 12) PROVIDE PRODUCT APPROVALS FOR THE
 108"X 60" HORIZONTAL GLIDER WINDOW WITH
 XOX CONFIGURATION SHOWN ON THE PLANS.
 THE NORANDEX SUBMITTAL DOES NOT COVER
 THIS SIZE OR CONFIGURATION.
  
 13) PLEASE INDICATE WHICH OPTIONS ARE
 BEING USED AND CROSS OUT THOSE THAT ARE
 NOT.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-02-13 Cont ID  
Sent By jleech Date 2003-02-12 Time 18:11 Rev Time 0.50
Received By btrobaug Date 2003-02-13 Time 09:05 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-04-02 Cont ID  
Sent By shernand Date 2003-04-02 Time 15:53 Rev Time 0.00
Received By shernand Date 2003-04-02 Time 15:53 Sent To Z
Notes
2003-04-02 00:00:00RM DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-03-12 Cont ID  
Sent By sthyng Date 2003-03-12 Time 16:44 Rev Time 0.00
Received By sthyng Date 2003-03-12 Time 16:44 Sent To B
Notes
2003-03-12 00:00:00TO RM DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-03-05 Cont ID  
Sent By dpalmer Date 2003-03-05 Time 10:47 Rev Time 0.00
Received By dpalmer Date 2003-03-05 Time 10:47 Sent To B
Notes
2003-03-05 00:00:00TO R MCDOUGAL'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-01-29 Cont ID  
Sent By dpalmer Date 2003-01-29 Time 13:07 Rev Time 0.00
Received By dpalmer Date 2003-01-29 Time 13:07 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-02-12 Cont ID  
Sent By rmcdouga Date 2003-02-11 Time 14:06 Rev Time 0.33
Received By jleech Date 2003-02-12 Time 18:11 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-02-08 Cont ID  
Sent By sgraham Date 2003-02-04 Time 16:28 Rev Time 0.25
Received By jleech Date 2003-02-08 Time 09:27 Sent To M
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2003-04-08 Cont ID  
Sent By rmcdouga Date 2003-04-08 Time 10:34 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
2003-04-08 00:00:00REVISION TO FLIP HOUSE ON SAME LOT
 (MIRROR IMAGE) IS OK. NEW REVERSED PLANS
 FOR SAME HOUSE SUBMITTED AND RESTAMPED
 AS REQUIRED BUY BILL STAPLES. 4-8-03 RM

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2003-04-08 Cont ID  
Sent By rmcdouga Date 2003-04-07 Time 10:36 Rev Time 2.00
Received By rmcdouga Date 2003-04-08 Time 10:33 Sent To  
Notes
2003-04-07 00:00:00REVISION TO FLIP STRUCTURE ON LOT WAS
 SUBMITTED WITH ONLY THE SURVEY. A NEW
 SET OF PLANS SHOWING NEW CONFIGURATION
 IS ALSO REQUIRED PER BILL STAPLES.

Review Stop Z ZONING
Rev No 2 Status P Date 2003-04-04 Cont ID  
Sent By sgraham Date 2003-04-04 Time 14:24 Rev Time 0.00
Received By sgraham Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-02-04 Cont ID  
Sent By shernand Date 2003-04-02 Time 16:06 Rev Time 0.00
Received By sgraham Date   Time   Sent To P
Notes
***NONE***