Plan Review Details - Permit 03011785
Plan Review Stops For Permit 03011785
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-02-21 Cont ID  
Sent By btrobaug Date 2003-02-05 Time 13:30 Rev Time 2.00
Received By jgomez Date 2003-02-21 Time 11:58 Sent To  
Notes
2003-02-21 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS UNDER A SEPARATE PERMIT.
 2-FLOOD ZONE A8. NEED TO PROVIDE THE
 ELEVATION CERTIFICATE.
 3-CLAIFY/REVISE HEIGHT OF HANDRAIL AND
 GUARDRAIL. SEE SEC. 1007.5.1 FBC 2001,
 NOTE #24 ON SHEET A-1 AND NOTE #1 AND
 STAIR SECTION ON SHEET A-4. REVISE AS
 REQUIRED.
 4-PROVIDE SOIL TEST REPORT PRIOR TO
 CONSTRUCTION.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-08-11 Cont ID  
Sent By dpalmer Date 2003-08-11 Time 06:43 Rev Time 0.25
Received By dpalmer Date 2003-08-11 Time 06:43 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-02-05 Cont ID  
Sent By alange Date 2003-08-05 Time 15:51 Rev Time 0.50
Received By btrobaug Date 2003-02-05 Time 13:30 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-08-05 Cont ID  
Sent By alange Date 2003-08-05 Time 15:51 Rev Time 0.00
Received By alange Date 2003-08-05 Time 15:51 Sent To E
Notes
2003-08-05 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-07-31 Cont ID  
Sent By alange Date 2003-07-31 Time 15:03 Rev Time 0.00
Received By alange Date 2003-07-31 Time 15:03 Sent To E
Notes
2003-07-31 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-03-05 Cont ID  
Sent By dpalmer Date 2003-03-05 Time 10:51 Rev Time 0.00
Received By dpalmer Date 2003-03-05 Time 10:51 Sent To M
Notes
2003-03-05 00:00:00TO HM'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-01-24 Cont ID  
Sent By dpalmer Date 2003-01-24 Time 12:33 Rev Time 0.00
Received By dpalmer Date 2003-01-24 Time 12:33 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-08-11 Cont ID  
Sent By pkrauss Date 2003-08-11 Time 07:23 Rev Time 0.25
Received By pkrauss Date 2003-08-11 Time 07:13 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-03-10 Cont ID  
Sent By dpalmer Date 2003-03-05 Time 10:51 Rev Time 0.25
Received By hmoser Date 2003-03-10 Time 18:03 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-02-03 Cont ID  
Sent By kstevens Date 2003-01-30 Time 12:28 Rev Time 0.25
Received By hmoser Date 2003-02-03 Time 19:40 Sent To E
Notes
2003-02-03 00:00:00PLAN DENIED
 1) ENERGY PERFORMANCE LEVEL DISPLAY CARD
 AND ENERGY CALCULATIONS DO NOT MATCH.
 2) EQUIPMENT SELESTION ON MANUAL (J) NOT
 COMPLETE.
 3) COOLING & HEATING BTU.ON MANUAL (J)
 DO NOTMATCH PLANS.
 PLAN REVIEW BY HAROLD MOSER
 (561)689-8096 EXT.8390

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-01-30 Cont ID  
Sent By sgraham Date 2003-01-24 Time 16:23 Rev Time 0.25
Received By kstevens Date 2003-01-30 Time 12:16 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-01-24 Cont ID  
Sent By dpalmer Date 2003-01-24 Time 12:34 Rev Time 0.00
Received By sgraham Date   Time   Sent To P
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved