Plan Review Details - Permit 03011622
Plan Review Stops For Permit 03011622
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2003-10-03 Cont ID  
Sent By lsmith Date 2003-09-29 Time 10:47 Rev Time 1.00
Received By lsmith Date 2003-09-29 Time 10:47 Sent To  
Notes
2003-09-29 00:00:00BUILDING REVISION FAILED
  
 1. MUST APPLY FOR SEPARATE PERMIT FOR
 PAVER DRIVEWAY & FENCE.
 2. NEED HISTORIC APPROVAL FOR ALL
 EXTERIOR WORK.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-08-11 Cont ID  
Sent By csiegber Date 2003-09-29 Time 08:59 Rev Time 0.75
Received By lsmith Date 2003-08-11 Time 13:04 Sent To  
Notes
2003-08-11 00:00:00ADDED A COVERED PATIO TO PERMIT: SEE
 NOTE ON PLAN. LS

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-03-15 Cont ID  
Sent By btrobaug Date 2003-08-08 Time 16:44 Rev Time 0.50
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-02-28 Cont ID  
Sent By dpalmer Date 2003-03-05 Time 11:30 Rev Time 1.00
Received By lsmith Date 2003-02-28 Time 08:37 Sent To  
Notes
2003-02-28 00:00:00****************FAILED******************
  
  
 1. NEED ENERGY CALACS. FOR NEW ADDITION
 2. NEED PRODUCT APPROVALS FOR STORM
 PANELS.
  
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 659-8096 EXT. 8394

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-08-08 Cont ID  
Sent By btrobaug Date 2003-08-08 Time 13:50 Rev Time 0.50
Received By btrobaug Date 2003-08-08 Time 11:35 Sent To Z
Notes
2003-08-08 00:00:00TO SHIRLEY,NEEDS HISTORIC./WRT.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2003-05-08 Cont ID  
Sent By btrobaug Date 2003-05-08 Time 14:44 Rev Time 1.00
Received By btrobaug Date 2003-05-08 Time 14:08 Sent To B
Notes
2003-05-08 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE MAKE THE FOLLOWING CHANGES TO
 THE PLANS FOR CODE COMPLIANCE,AND
 RESUBMIT FOR REVIEW.
  
 1} NOTE THE #2 FEEDER SHOWN IS ONLY
 RATED FOR 125 AMPS.PLEASE CHECK THE
 SIZE AT THE SERVICE AND IF THE CORRECT
 SIZE IS #2 THE MAIN BREAKER MUST BE
 CHANGED TO 125 AMPS,OR THE SERVICE MUST
 BE UPGRADED TO 200 AMPS WITH 2/0 WIRE.
  
 2} PLEASE NOTE FRONT AND REAR
 RECEPTS REQ'D PER 210-52E
  
 3} PLEASE NOTE KITCHEN COUNTER-
 -SPACE RECEPT SPACING SHALL MEET ART;
 210-52C 1,2,3,4,AND 5.ALSO SHALL BE GFI
 PROTECTED PER 210-8(A)(6),LIST SAME ON
 PLANS.
  
 4} THE RECEPTACLE SPACING IN THE
 FAMILY,OFFICE AND MASTER BEDROOMS MUST
 COMPLY WITH 210-52. SEE REDLINED PLANS.
  
 5} THERE MUST BE A RECEPTACLE IN THE
 MASTER BATH TO COMPLY WITH 210-52(D).
  
 6} PLEASE LIST THE REQ'D BATH(S)
 CIRCUIT(S), PER 210-11-C-3
 MUST BE 20A AND #12AWG,ON PANEL
 SCHEDULE.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-02-25 Cont ID  
Sent By shernand Date 2003-05-02 Time 17:46 Rev Time 1.00
Received By btrobaug Date 2003-02-25 Time 12:12 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2003-09-29 Cont ID  
Sent By csiegber Date 2003-09-29 Time 08:59 Rev Time 0.00
Received By csiegber Date 2003-09-29 Time 08:59 Sent To B
Notes
2003-09-29 00:00:00TO LS DESK

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2003-09-25 Cont ID  
Sent By mmclean Date 2003-09-26 Time 10:58 Rev Time 0.00
Received By csiegber Date 2003-09-25 Time 11:08 Sent To B
Notes
2003-09-25 00:00:00TO LS DESK

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2003-08-08 Cont ID  
Sent By btrobaug Date 2003-08-08 Time 16:44 Rev Time 0.00
Received By btrobaug Date 2003-08-08 Time 16:44 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2003-08-01 Cont ID  
Sent By alange Date 2003-08-01 Time 15:50 Rev Time 0.00
Received By alange Date 2003-08-01 Time 15:50 Sent To B
Notes
2003-08-01 00:00:00TO L SMITH DESK

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2003-07-24 Cont ID  
Sent By mmclean Date 2003-08-01 Time 15:11 Rev Time 0.00
Received By alange Date 2003-07-24 Time 15:40 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2003-05-02 Cont ID  
Sent By shernand Date 2003-05-02 Time 17:46 Rev Time 0.00
Received By shernand Date 2003-05-02 Time 17:46 Sent To E
Notes
2003-05-02 00:00:00BT DESK

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-03-05 Cont ID  
Sent By dpalmer Date 2003-03-05 Time 11:30 Rev Time 0.00
Received By dpalmer Date 2003-03-05 Time 11:30 Sent To B
Notes
2003-03-05 00:00:00TO LS'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-03-13 Cont ID  
Sent By lmartine Date 2003-02-25 Time 11:28 Rev Time 0.00
Received By lsmith Date 2003-03-13 Time 11:55 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-02-12 Cont ID  
Sent By btrobaug Date 2003-02-12 Time 16:34 Rev Time 0.00
Received By btrobaug Date 2003-02-10 Time 16:33 Sent To P
Notes
2003-02-12 00:00:00"P" IN BOX,PUT SUBMITTAL(BLDG) WITH PLAN
 WRT.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-02-11 Cont ID  
Sent By dpalmer Date 2003-02-11 Time 14:02 Rev Time 0.00
Received By dpalmer Date 2003-02-11 Time 14:02 Sent To P
Notes
2003-02-11 00:00:00TO PLUMB INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-01-22 Cont ID  
Sent By btrobaug Date 2003-01-22 Time 17:39 Rev Time 0.00
Received By btrobaug Date 2003-01-22 Time 17:39 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2003-03-13 Cont ID  
Sent By pkrauss Date 2003-03-13 Time 10:20 Rev Time 0.25
Received By pkrauss Date 2003-03-13 Time 10:20 Sent To  
Notes
2003-03-13 00:00:00MECHANICAL PERMIT TO BE APPLIED FOR
 SEPARATELY (AS PER R. FRANCIS G.C.).
 ENERGY CALCS TO BE SUBMITTED WITH
 MECHANICAL PERMIT.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2003-02-25 Cont ID  
Sent By kstevens Date 2003-03-13 Time 09:55 Rev Time 0.35
Received By pkrauss Date 2003-02-25 Time 13:30 Sent To  
Notes
2003-02-25 00:00:00DENIED:
 PROVIDE THE FOLLOWING INFORMATION WITH
 MECHANICAL PERMIT APPLICATION.
  
 NO MECHANICAL INFORMATION SUBMITTED FOR
 REVIEW.PLEASE PROVIDE ENERGY & MANUAL
 J CALCS.INDICATE NEW OR EXISTING
 EQUIPMENT & PROVIDE EQUIPMENT
 INFORMATION (MAKE, MODEL, BTU OF THE
 AHU, & SEER OF CONDENSER UNIT).
 PROVIDEDUCT SIZE, MATERIAL, AND LAYOUT.
 INDICATE GRILLE SIZE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-03-13 Cont ID  
Sent By lsmith Date 2003-08-07 Time 10:30 Rev Time 0.25
Received By kstevens Date 2003-03-13 Time 09:55 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-02-27 Cont ID  
Sent By lsmith Date 2003-03-12 Time 15:17 Rev Time 0.33
Received By kstevens Date 2003-02-27 Time 15:18 Sent To B
Notes
2003-02-27 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) SANITARY RISER DIAGRAM DOES NOT RE-
 FLECT FLOOR PLAN. MASTER BATH SHOWS TWO
 SHOWERS ON RISER DIAGRAM AND ONLY ONE
 SHOWER ON FLOOR PLAN. PLEASE CLAIRFY.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 5 Status P Date 2003-09-26 Cont ID  
Sent By mmclean Date 2003-09-26 Time 10:58 Rev Time 0.00
Received By mmclean Date   Time   Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 4 Status P Date 2003-08-01 Cont ID  
Sent By btrobaug Date 2003-08-08 Time 13:50 Rev Time 0.00
Received By mmclean Date   Time   Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status F Date 2003-07-29 Cont ID  
Sent By mmclean Date 2003-07-29 Time 11:06 Rev Time 0.00
Received By mmclean Date   Time   Sent To  
Notes
2003-07-29 00:00:007/29/03 NEED EASEMENT RELEASE CALLED
 CONTR FILE R TO PICK UP ONE SITE PLAN MM

Review Stop Z ZONING
Rev No 2 Status P Date 2003-02-10 Cont ID  
Sent By alange Date 2003-07-24 Time 15:40 Rev Time 0.00
Received By sgraham Date   Time   Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2003-01-24 Cont ID  
Sent By btrobaug Date 2003-01-22 Time 17:41 Rev Time 0.00
Received By sgraham Date   Time   Sent To P
Notes
2003-01-24 00:00:00DENIED BY ZONING
 1. NEED SURVEY
 2. MAX HEIGHT OF BLDGMUST 33'