Plan Review Stops For Permit 03011496 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2003-02-21 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-02-10 |
Time |
13:52 |
Rev Time |
2.00 |
Received By |
jgomez |
Date |
2003-02-21 |
Time |
08:54 |
Sent To |
|
|
Notes |
2003-02-21 00:00:00 | BULDING REVIEW APPROVED WITH PROVISO: | | 1-PROVIDE COMPLETE INFORMATION FOR STORM | | SHUTTER UNDER A SEPARATE PERMIT. | | 2-FLOOD ZONE A8. NEED TO PROVIDE THE | | ELEVATION CERTIFICATE. | | 3-SEE SECTION 1007.5.1 FBC 2001 AND | | CLARIFY HEIGHT OF HANDRAIL ON NOTE #24 | | SHEET A-1 AND NOTE #1 ON SHEET A-4. | | NOTE: HANDRAIL AND GUARDRAIL ARE NOT | | THE SAME. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2003-02-10 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2003-02-08 |
Time |
12:16 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2003-02-10 |
Time |
13:52 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-07-08 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-07-08 |
Time |
16:04 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-07-08 |
Time |
16:04 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-07-01 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-07-01 |
Time |
12:49 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-07-01 |
Time |
12:49 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-03-05 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-03-05 |
Time |
10:49 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2003-03-05 |
Time |
10:49 |
Sent To |
M |
|
Notes |
2003-03-05 00:00:00 | TO JL'S DESK. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2003-07-11 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-07-11 |
Time |
14:39 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2003-07-11 |
Time |
14:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2003-07-03 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-07-08 |
Time |
16:04 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2003-07-03 |
Time |
14:29 |
Sent To |
|
|
Notes |
2003-07-03 00:00:00 | DENIED: | | | | WRONG FLOOR PLAN SUBMITTED FOR REVIEW. | | SHOULD BE A GARAGE RIGHT INSTEAD OF | | LEFT. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2003-03-11 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-07-01 |
Time |
12:49 |
Rev Time |
0.25 |
Received By |
hmoser |
Date |
2003-03-11 |
Time |
20:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2003-02-08 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2003-02-01 |
Time |
11:36 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2003-02-08 |
Time |
12:16 |
Sent To |
E |
|
Notes |
2003-02-08 00:00:00 | DENIED; | | PLAN DENIED | | 1) ENERGY PERFORMANCE LEVEL DISPLAY CARD | | AND ENERGY CALCULATIONS DO NOT MATCH. | | 2) EQUIPMENT SELESTION ON MANUAL (J) NOT | | COMPLETE. | | 3) COOLING & HEATING BTU.ON MANUAL (J) | | DO NOTMATCH PLANS. | | PLAN REVIEW BY HAROLD MOSER | | (561)689-8096 EXT.8390 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2003-02-01 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2003-01-24 |
Time |
16:21 |
Rev Time |
0.25 |
Received By |
jleech |
Date |
2003-02-01 |
Time |
11:35 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-01-24 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2003-01-24 |
Time |
16:21 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
P |
|
Notes |
|
|