Plan Review Details - Permit 03011285
Plan Review Stops For Permit 03011285
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-03-06 Cont ID  
Sent By jgomez Date 2003-03-06 Time 16:37 Rev Time 0.25
Received By jgomez Date 2003-03-06 Time 16:37 Sent To  
Notes
2003-03-06 00:00:00BUILDING REVIEW APPROVED. SEE PROVISO
 DATED 2-13-03.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-02-13 Cont ID  
Sent By dpalmer Date 2003-02-05 Time 07:43 Rev Time 2.00
Received By jgomez Date 2003-02-13 Time 11:08 Sent To  
Notes
2003-02-13 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS UNDER A SEPARATE PERMIT.
 2-FLOOD ZONE A8. NEED TO PROVIDE THE
 ELEVATION CERTIFICATE.
 3-SHEET A-1: REVISE NOTE #24. SEE SEC.
 1007.5.1 FBC 2001 FOR HANDRAIL HEIGHT.
 4-GLASS BLOCK TO BE SAFETY GLASS IF FACE
 THICKNESS IS LESS THAN 0.25". SECTION
 2405.2.2 FBC 2001.
 5-SHEET A-4: REVISE NOTE #1. SEE SECTION
 1007.5.1 FBC 2001 FOR HANDRAIL HEIGHT.
 6-PROVIDE GENERAL SPECS FOR FIREBLOCKING
 AT ALL CONCEALED SPACES AS REQUIRED BY
 SEC. 2305.1.4 FBC 2001.
 7-PROVIDE COMPLETE DETAIL/SECTION FOR
 CONNECTION AT TOP OF COLUMN LOCATED
 BETWEEN GARAGE AND KITCHEN AND SHOWING
 HOW ARE THE TWO TRUSSES SUPPORTED.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 8-SHEET S-3: PROVIDE SPECS ON STRUCTURAL
 WALL SECTIONS FOR FIRECUT REQUIREMENTS
 SEC. 2305.4 FBC 2001.
 9-DETAIL R19: SPECIFY ALL CONNECTORS.
 ROOF FRAMING PLAN DOESN'T SPECIFY THEM
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 10-GARAGE DOOR STRUCTURAL BUCK DETAIL:
 SPECIFY HOW MUCH EMBEDMENT FOR ANCHOR
 AND WASHER SIZE. SECTION 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
 11-PROVIDE SOIL TEST REPORT PRIOR TO
 CONSTRUCTION.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-02-05 Cont ID  
Sent By hmoser Date 2003-02-03 Time 18:55 Rev Time 0.33
Received By dpalmer Date 2003-02-05 Time 07:43 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-07-08 Cont ID  
Sent By shernand Date 2003-07-08 Time 16:08 Rev Time 0.00
Received By shernand Date 2003-07-08 Time 16:08 Sent To M
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-07-11 Cont ID  
Sent By pkrauss Date 2003-07-11 Time 14:33 Rev Time 0.25
Received By pkrauss Date 2003-07-11 Time 14:33 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-03-01 Cont ID  
Sent By shernand Date 2003-07-08 Time 16:08 Rev Time 0.25
Received By hmoser Date 2003-03-01 Time 08:46 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-02-03 Cont ID  
Sent By kstevens Date 2003-01-28 Time 07:46 Rev Time 0.25
Received By hmoser Date 2003-02-03 Time 18:55 Sent To E
Notes
2003-02-03 00:00:00PLAN DENIED
 1) ENERGY PERFORMANCE LEVEL DISPLAY CARD
 AND ENERGY CALCULATIONS DO NOT MATCH.
 2) EQUIPMENT SELESTION ON MANUAL (J) NOT
 COMPLETE.
 3) COOLING & HEATING BTU.ON MANUAL (J)
 DO NOTMATCH PLANS.
 PLAN REVIEW BY HAROLD MOSER
 (561)689-8096 EXT.8390

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-01-28 Cont ID  
Sent By sgraham Date 2003-01-24 Time 16:29 Rev Time 0.25
Received By kstevens Date 2003-01-28 Time 07:43 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-01-24 Cont ID  
Sent By sgraham Date 2003-01-24 Time 16:29 Rev Time 0.00
Received By sgraham Date   Time   Sent To P
Notes
***NONE***