Plan Review Details - Permit 03011090
Plan Review Stops For Permit 03011090
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-04-28 Cont ID  
Sent By jgomez Date 2003-04-28 Time 10:57 Rev Time 2.00
Received By jgomez Date 2003-04-28 Time 10:57 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-03-28 Cont ID  
Sent By shernand Date 2003-04-25 Time 11:16 Rev Time 1.00
Received By jgomez Date 2003-03-28 Time 11:53 Sent To  
Notes
2003-03-28 00:00:00BUILDING REVIEW 2ND CHECKLIST:
 1-AREA CALCULATIONS WERE NOT REVISED BY
 THE ARCHITECT. SEE SHEET C-1 AND A-1
 AND REVISE ACCORDINGLY.
 2-ENERGY CALCULATIONS TO HAVE ENGINEER
 ORIGINAL SIGNATURE AND SEAL AS REQ'D
 BY CHAPTER 471 FLORIDA STATUTES AND
 SEC. 103.0 CHAPTER 13 FBC 2001.
 3-REVISE STORM SHUTTERS INSTALLATION
 SCHEDULE TO MATCH INFORMATION GIVEN ON
 THE ENGINEERING DRAWINGS. CHECK THE
 DESIGN PRESSURES AND THE MAXIMUM PANEL
 SPAN ALLOWED. ALSO, CHECK FOR ANCHOR
 SPACING ACCORDING TO DESIGN PRESSURES,
 EDGE DISTANCE, CONNECTION TYPE AND
 PANEL SPAN SHOWN ON ENGINEERED DWGS.
 **CLARIFY WHY SOME SUBMITTAL HAVE SBCCI
 PRODUCT APPROVAL AND SOME SUBMITTALS
 ARE DONE SITE SPECIFIC.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-02-06 Cont ID  
Sent By pkrauss Date 2003-03-27 Time 14:12 Rev Time 1.00
Received By jgomez Date 2003-02-06 Time 14:06 Sent To  
Notes
2003-02-06 00:00:00BUILDING REVIEW CHECKLIST:
 1-AREA CALCULATIONS ARE INCORRECT.
 REVISE PLANS AS REQUIRED.
 2-REVISE ENERGY CALCULATIONS AS REQUIRED
 TO MATCH CORRECTED FLOOR PLANS.
 3-REVISE IMPACT FEE A/C AREA TO MATCH
 CORRECTED PLANS.
 4-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS OR APPLY FOR SEPARATE PERMIT.
 5-PROVIDE COMPLETE SPECIFICATIONS FOR
 GARAGE DOOR STRUCTURAL BUCK DETAIL.
 SPECIFY ANCHOR EMBEDMENT AND WASHER
 SIZE. SEC. 104.2.1.2 CITY AMENDMENTS.
 6-BUILDING SECTION A/A-5: REVISE HEIGHT
 OF HANDRAIL. SEE SEC. 1007.5.1 FBC
 2001. **NOTE: HANDRAIL AND GUARDRAIL
 ARE NOT THE SAME.
 7-NEED RECORDED NOTICE OF COMMENCEMENT.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-08-27 Cont ID  
Sent By dpalmer Date 2003-08-27 Time 10:04 Rev Time 0.25
Received By dpalmer Date 2003-08-27 Time 10:04 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-02-04 Cont ID  
Sent By csiegber Date 2003-08-19 Time 14:42 Rev Time 0.33
Received By dpalmer Date 2003-02-04 Time 06:51 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2003-09-11 Cont ID  
Sent By csiegber Date 2003-09-11 Time 11:27 Rev Time 0.00
Received By csiegber Date 2003-09-11 Time 11:27 Sent To M
Notes
2003-09-11 00:00:00TO PK DESK

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-08-21 Cont ID  
Sent By csiegber Date 2003-08-21 Time 13:16 Rev Time 0.00
Received By csiegber Date 2003-08-21 Time 13:16 Sent To M
Notes
2003-08-21 00:00:00TO PK DESK

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-08-19 Cont ID  
Sent By csiegber Date 2003-08-27 Time 10:19 Rev Time 0.00
Received By csiegber Date 2003-08-19 Time 14:41 Sent To  
Notes
2003-08-19 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-04-25 Cont ID  
Sent By shernand Date 2003-04-25 Time 11:16 Rev Time 0.00
Received By shernand Date 2003-04-25 Time 11:16 Sent To B
Notes
2003-04-25 00:00:00JGOMEZ DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-03-19 Cont ID  
Sent By sthyng Date 2003-03-19 Time 13:04 Rev Time 0.00
Received By sthyng Date 2003-03-19 Time 13:03 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-01-17 Cont ID  
Sent By btrobaug Date 2003-01-17 Time 17:05 Rev Time 0.00
Received By btrobaug Date 2003-01-17 Time 17:05 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2003-09-04 Cont ID  
Sent By csiegber Date 2003-09-11 Time 11:27 Rev Time 0.20
Received By pkrauss Date 2003-09-04 Time 08:40 Sent To  
Notes
2003-09-04 00:00:00DENIED:
  
 SEER ON THE EQUIPMENT SUBMITTED ON
 REVISED PLANS ARE LESS THAN THE MINIMUM
 REQUIRED ON THE ENERGY CALCS.
  
 REVISED PLAN SUBMITTED SEER = 10.0
 ENERGY CALCS SEER = 11.0
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-03-27 Cont ID  
Sent By csiegber Date 2003-08-21 Time 13:16 Rev Time 0.30
Received By pkrauss Date 2003-03-27 Time 14:02 Sent To B
Notes
2003-03-27 00:00:00MECHANICAL PERMIT 03011098

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-02-03 Cont ID  
Sent By sthyng Date 2003-03-19 Time 13:21 Rev Time 0.33
Received By jleech Date 2003-02-03 Time 17:42 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-01-25 Cont ID  
Sent By btrobaug Date 2003-01-17 Time 17:14 Rev Time 0.25
Received By jleech Date 2003-01-25 Time 11:41 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-04-28 Cont ID  
Sent By jgomez Date 2003-04-28 Time 10:56 Rev Time 0.00
Received By jgomez Date 2003-04-28 Time 10:56 Sent To  
Notes
2003-04-28 00:00:00APPROVED BY ZONING 1-17-03. SEE SURVEY.