Plan Review Details - Permit 03011086
Plan Review Stops For Permit 03011086
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-04-22 Cont ID  
Sent By jgomez Date 2003-04-22 Time 14:57 Rev Time 0.50
Received By jgomez Date 2003-04-22 Time 14:57 Sent To  
Notes
2003-04-22 00:00:00REVISION: CHANGE TOP OF BEAM ELEVATIOM
 AT ZERO LOT LINE WALL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-02-12 Cont ID  
Sent By dpalmer Date 2003-02-05 Time 07:13 Rev Time 2.00
Received By jgomez Date 2003-02-12 Time 17:49 Sent To  
Notes
2003-02-12 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-PROVIDE COMPLETE INFORMATION ON DETAIL
 41/S1. MISSING ANCHOR AND WASHER SIZE.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 2-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS UNDER A SEPARATE PERMIT.
 3-REVISE EXTERIOR RIGHT ELEVATION NOTE
 #4. BEAM HEIGHT WAS RAISED TO AVOID
 ONE HR FIRE RATED ASSEMBLY AT THE END
 OF TRUSS AS REQUIRED BY TABLE 600 FBC.
 SEE BUILDING SECTION.
 4-PROVIDE DETAIL CONNECTION AT TOP OF
 COLUMN P2. SEE SECOND FLOOR FRAMING
 PLAN.SEC. 104.2.1.2 CITY AMENDMENTS
 TO FBC 2001.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-02-05 Cont ID  
Sent By dpalmer Date 2003-02-05 Time 07:13 Rev Time 0.25
Received By dpalmer Date 2003-02-05 Time 07:13 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-05-22 Cont ID  
Sent By shernand Date 2003-05-22 Time 15:30 Rev Time 0.00
Received By shernand Date 2003-05-22 Time 15:30 Sent To M
Notes
2003-05-22 00:00:00MECH REVISION

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-01-17 Cont ID  
Sent By btrobaug Date 2003-01-17 Time 17:06 Rev Time 0.00
Received By btrobaug Date 2003-01-17 Time 17:06 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-06-03 Cont ID  
Sent By pkrauss Date 2003-06-03 Time 13:08 Rev Time 0.25
Received By pkrauss Date 2003-06-03 Time 13:07 Sent To  
Notes
2003-06-03 00:00:00MECH REV PERMIT 03011102

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-02-13 Cont ID  
Sent By shernand Date 2003-05-22 Time 15:30 Rev Time 0.35
Received By pkrauss Date 2003-02-13 Time 12:37 Sent To  
Notes
2003-02-13 00:00:00MECHANICAL PERMIT 03011102
 FAN SHUTDOWN REQUIRED AT FINAL
 INSPECTION.

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-02-13 Cont ID  
Sent By btrobaug Date 2003-01-17 Time 17:15 Rev Time 0.25
Received By pschmitz Date   Time   Sent To  
Notes
2003-02-13 00:00:00APPROVED BY JHL 1-25-03, LOGIN BY PES
 2-13-03.

Review Stop Z ZONING
Rev No 1 Status P Date 2003-01-17 Cont ID  
Sent By sgraham Date 2003-01-17 Time 12:12 Rev Time 0.00
Received By sgraham Date   Time   Sent To P
Notes
***NONE***