Plan Review Details - Permit 03011052
Plan Review Stops For Permit 03011052
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-02-21 Cont ID  
Sent By shernand Date 2003-05-07 Time 14:52 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
2003-02-21 00:00:00BUILDING PROVISO
  
 1) SUBMIT MANUFACTURER'S SPECIFICATIONS
 AND UL LISTING INFORMATION FOR THE ONE
 HOUR FIRE RATED GLASS BLOCK AT THE ZERO
 LOT LINE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-02-10 Cont ID  
Sent By dpalmer Date 2003-02-20 Time 16:15 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2003-02-10 00:00:00BUILDING DENIED
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) PLEASE CLARIFY NOTE #9 UNDER GENERAL
 NOTES ON SHEET 1 TO INCLUDE WINDOWS THAT
 ARE WITHIN THREE FEET HORIZONTALLY OF
 THE TUB OR SHOWER. SEE FBC 2405.2.1.
  
 3) SPECIFY ON THE PLANS THAT THE WIRE
 MESH IN THE SLAB IS REQUIRED TO BE
 SUPPORTED AT A MAXIMUM OF THREE FEET ON
 CENTER PER FBC 1909.3.
  
 4) SPECIFY THE SIZES OF THE FIXED GLASS
 TRANSOM AND THE AND THE SIDELITE AT THE
 FRONT DOOR ON THE PLANS.
  
 5) THE ROOF FRAMING PLAN ON 3A, 3B AND
 3C SPECIFY AN A-5 TRUSS CONNECTOR FOR
 THE HIP GIRDER AT THE GARAGE. HOWEVER,
 THERE IS NO A-5 CONNECTOR LISTED IN THE
 ANCHOR SCHEDULE ON SHEET 2. PLEASE
 CLARIFY.
  
 6) DETAIL 3 ON 4 DOES NOT SPECIFY THE
 LENGTH OR EMBEDMENT DEPTH OF THE 5/8"
 EXPANSION BOLTS FOR THE OVERHEAD GARAGE
 DOOR. PLEASE SPECIFY.
  
 7) THE HVAC CREDIT IS BEING TAKEN FOR
 CEILING FANS ON THE ENERGY CALCULATIONS.
 PLEASE INDICATE THE REQUIRED MINIMUM FAN
 SIZE FOR EACH ROOM ON THE PLANS. SEE FBC
 CHAPTER 13-607.1.A.1 AND TABLE 6-6.
  
 8) PROVIDE THE MANUFACTURER'S SPECS. AND
 UL LISTING INFORMATION FOR THE ONE HOUR
 FIRE RATED GLASS BLOCK ASSEMBLY.
  
 9) THE JOB LOCATION IS REQUIRED TO BE ON
 THE SITE SPECIFIC PRODUCT APPROVALS FROM
 NORANDEX.
  
 10) THERE IS NO PRODUCT INFORMATION IN
 THE NORANDEX SITE SPECIFIC APPROVALS FOR
 THE 96"X 60" GLIDER WINDOW WITH AN XOX
 CONFIGURATION. PLEASE SUBMIT ONE.
  
 11) THE SURVEY HAS THE INCORRECT LOMR
 CASE # AND DATE FOR THE FLOOD ZONE.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-02-24 Cont ID  
Sent By btrobaug Date 2003-02-24 Time 07:37 Rev Time 0.50
Received By btrobaug Date 2003-02-21 Time 18:02 Sent To P
Notes
2003-02-24 00:00:00TO JOHN L./WRT

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-02-03 Cont ID  
Sent By jleech Date 2003-02-01 Time 14:15 Rev Time 0.50
Received By btrobaug Date 2003-02-03 Time 16:40 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-05-07 Cont ID  
Sent By shernand Date 2003-05-07 Time 14:52 Rev Time 0.00
Received By shernand Date 2003-05-07 Time 14:52 Sent To B
Notes
2003-05-07 00:00:00RM DESK, NEED PLANS RESTAMPED.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-02-20 Cont ID  
Sent By dpalmer Date 2003-02-20 Time 16:14 Rev Time 0.00
Received By dpalmer Date 2003-02-20 Time 16:14 Sent To B
Notes
2003-02-20 00:00:00TO RMCD.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-02-10 Cont ID  
Sent By rmcdouga Date 2003-02-10 Time 10:54 Rev Time 0.00
Received By rmcdouga Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-02-22 Cont ID  
Sent By jleech Date 2003-02-22 Time 07:05 Rev Time 0.33
Received By jleech Date 2003-02-22 Time 07:05 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-02-01 Cont ID  
Sent By jleech Date 2003-02-01 Time 14:14 Rev Time 0.33
Received By jleech Date 2003-02-01 Time 14:14 Sent To E
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2003-01-17 Cont ID  
Sent By jleech Date 2003-01-25 Time 09:11 Rev Time 0.00
Received By btrobaug Date 2003-01-17 Time 16:12 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-02-22 Cont ID  
Sent By btrobaug Date 2003-02-24 Time 09:00 Rev Time 0.25
Received By jleech Date 2003-02-22 Time 07:06 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-01-25 Cont ID  
Sent By btrobaug Date 2003-01-17 Time 16:13 Rev Time 0.25
Received By jleech Date 2003-01-25 Time 09:11 Sent To M
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2003-05-08 Cont ID  
Sent By rmcdouga Date 2003-05-08 Time 10:46 Rev Time 1.00
Received By rmcdouga Date 2003-05-08 Time 10:46 Sent To  
Notes
2003-05-08 00:00:00PLANS THAT WERE SUBMITTED FOR A RE-STAMP
 CONTAIN SHEETS THAT HAVE BEEN REVISED.
 SHEETS 1,2,4AND 5 SHOW THAT THE TUB IN
 BATH #2 HAS BEEN CHANGED TO A SHOWER.
 TWO SETS OF THE REVISED SHEETS ARE
 REQUIRED TO BE SUBMITTED FOR REVIEW AND
 A FEE WILL BE ASSESSED.

Review Stop Z ZONING
Rev No 1 Status P Date 2003-01-17 Cont ID  
Sent By sgraham Date 2003-01-17 Time 12:21 Rev Time 0.00
Received By sgraham Date   Time   Sent To P
Notes
***NONE***