Plan Review Stops For Permit 03010452 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2003-01-29 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-29 |
Time |
15:04 |
Rev Time |
2.50 |
Received By |
lhatten |
Date |
2003-01-28 |
Time |
09:08 |
Sent To |
|
|
Notes |
2003-01-29 00:00:00 | REVIEW & STAMPED PLANS 01/28/2003 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2003-02-20 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-06 |
Time |
14:27 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2003-02-20 |
Time |
18:00 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2003-01-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-02-20 |
Time |
15:44 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2003-01-28 |
Time |
16:20 |
Sent To |
B |
|
Notes |
2003-01-28 00:00:00 | *********** UNSAT ******************** | | | | 1)NOTE: PLEASE REMOVE SD FROM KITCHEN | | AREA. NOT PERMITTED PER NFPA-72 8-1.4.1. | | 6. | | | | 2)NOTE: PLEASE NOTE, MISSING EQUIPMENT | | GROUNDING CONDUCTOR BETWEEN MAIN AND | | APNEL "B". SIZE PER 250-122 | | | | 3)NOTE: PLEASE SEE MIN SIZING OF GROUND- | | -ING ELECTRODE CONDUCTOR PER 250-66. | | PLEASE ALSO SEE MIN SIZE OF SERVICE | | CONDUCTORS FOR 400A SERVICE ON 310-15 | | FOR SIZING GROUNDING ELECTRODE. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWYE PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2003-10-06 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-06 |
Time |
14:27 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-10-06 |
Time |
14:26 |
Sent To |
E |
|
Notes |
2003-10-06 00:00:00 | TO DP DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2003-04-29 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-29 |
Time |
15:04 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-04-29 |
Time |
15:04 |
Sent To |
B |
|
Notes |
2003-04-29 00:00:00 | LHATTEN DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2003-04-29 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-29 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-04-29 |
Time |
15:00 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-02-20 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-02-20 |
Time |
15:44 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2003-02-20 |
Time |
15:43 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-01-16 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-01-16 |
Time |
17:51 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2003-01-16 |
Time |
17:51 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-01-09 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-01-09 |
Time |
18:32 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2003-01-09 |
Time |
18:32 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2003-03-03 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-03-03 |
Time |
14:16 |
Rev Time |
0.35 |
Received By |
pkrauss |
Date |
2003-03-03 |
Time |
14:16 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2003-01-21 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-03-01 |
Time |
12:18 |
Rev Time |
0.50 |
Received By |
hmoser |
Date |
2003-01-21 |
Time |
19:06 |
Sent To |
E |
|
Notes |
2003-01-21 00:00:00 | PLAN DENIED | | CFM.ON PLANS DO NOT MATCH CFM.ON | | MANUAL (J) | | PLAN REVIEW BY HAROLD MOSER | | (561)659-8096 EXT.8390 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2003-03-01 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-03-01 |
Time |
12:17 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2003-03-01 |
Time |
12:18 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2003-01-18 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-02-20 |
Time |
18:01 |
Rev Time |
0.50 |
Received By |
jleech |
Date |
2003-01-18 |
Time |
13:25 |
Sent To |
M |
|
Notes |
2003-01-18 00:00:00 | DENIED; | | PAGE A-1 PLUMBING RISER DIAGRAM; | | 1.ONLY FIXTURES IN THE BATHROOM GROUP | | SHALL CONNECT TO THE WET VENTED | | HORIZONTAL BRANCH DRAIN SEC. 909.1. | | 2.SEE TABLE909.3 ONLY 4 FU'S PERMITED ON | | 2" WET VENT. | | 3.MASTER BATHROOM. FLOOR PLAN SHOWS 2 | | LAVS. RISER DIAGRAM SHOWS 3. | | 4.SINK ON 2ND FL. ON RISER DIAGRAM IS | | NOT SHOWN ON FLOOR PLAN. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 659-8096 EXT.8369 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-03-03 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-01-09 |
Time |
18:32 |
Rev Time |
0.50 |
Received By |
lhatten |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2003-03-03 00:00:00 | OKED PER SHIRLEY GRAHAM 01/16/2003 |
|
|