Plan Review Stops For Permit 02121113 |
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2003-06-11 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-06-11 |
Time |
13:40 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2003-06-11 |
Time |
13:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2003-05-28 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-05-28 |
Time |
16:42 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2003-05-28 |
Time |
16:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2003-02-13 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-21 |
Time |
16:54 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2003-02-13 |
Time |
10:38 |
Sent To |
B |
|
Notes |
2003-02-13 00:00:00 | TO LOU HATTEN TO ORGANIZE PRODUCT | | APPROVALS AND LETTERS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2003-02-06 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-02-06 |
Time |
09:30 |
Rev Time |
1.00 |
Received By |
dpalmer |
Date |
2003-02-06 |
Time |
09:30 |
Sent To |
|
|
Notes |
2003-02-06 00:00:00 | ***************** UNSAT ************* | | | | 1)NOTE: PLEASE SEE FS/FAC PLANS MUST | | HAVE ORIG SIGNATURE BY ARCH OF RECORD. | | 481.221, ALL TRADES, ALL SHEETS. | | PLEASE ALSO TAKE OUT OLD SHEETS AND | | INSERT NEW. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2003-01-08 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-01-31 |
Time |
16:36 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2003-01-08 |
Time |
06:56 |
Sent To |
B |
|
Notes |
2003-01-08 00:00:00 | ************ UNSAT ********************* | | | | 1)NOTE: PLEASE SEE MISSING RECEPT FOR | | KITCHEN COUNTERSPACE. 210-52C-1 | | | | 2)NOTE: PLEASE SEE LOAD CALCULATIONS, | | SHOWS 4SM APPL AND WASHER AT 1500W,,= | | 6KW, PLEASE ADJUST 5X1500 IS 7500W. | | | | 3)NOTE: PLEASE ALSONOTE ONLY TWO SM | | APPL ARE SHOWN ON PANEL SCHEDULE AND | | NOTE, 210-52/210-11C-1 | | | | 4)NOTE: PLEASE SEE LOAD CALCS, RANGE | | SHOWN AT 12KW W/ 50A OCP. PLEASE ADJUST | | OCP DUE TO LOAD BEING MORETHAN BRKR | | RATING. | | | | 5)NOTE: PLEASE SEE 2P-25A BRKR FOR AHU | | #2. PLEASE SIZE PER 424-3B FOR 10KW | | UNIT. | | | | 6)NOTE: PLEASE SEE, ALL DISC`S FOR AHU | | AND COND UNITS TO MEET 110-26 | | | | 7)NOTE: PLEASE SEE FS/FAC ALL PLANS MUST | | CONTAIN ORIGINAL DATE, SIGNATURE AND | | SEAL. 471.025 AND 481.221 FOR ARCH AND | | ENGINEERS. PLANS ARE NOW STAMPED?? | | THIS IS REQ`D FOR ALL SHEETS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-05-21 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-21 |
Time |
16:54 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-05-21 |
Time |
16:54 |
Sent To |
E |
|
Notes |
2003-05-21 00:00:00 | BT DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-01-31 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-01-31 |
Time |
16:36 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2003-01-31 |
Time |
16:36 |
Sent To |
E |
|
Notes |
2003-01-31 00:00:00 | TO DVP./WRT |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2002-12-19 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-12-19 |
Time |
11:19 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2002-12-19 |
Time |
11:19 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-01-04 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2003-01-04 |
Time |
07:14 |
Rev Time |
0.50 |
Received By |
hmoser |
Date |
2003-01-04 |
Time |
12:39 |
Sent To |
E |
|
Notes |
2003-01-04 00:00:00 | PASS/PROVISO | | 1) NEED DUCT SIZE ON MANE TRUNKLINE | | 2) NEED DUCT SIZE IN LAUNDRY ROOM | | PLAN REVIEW BY HAROLD MOSER | | (651)659-8096 EXT.8390 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2003-01-04 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2002-12-23 |
Time |
13:06 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2003-01-04 |
Time |
07:14 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2003-01-28 |
|
|
Cont ID |
|
Sent By |
lhatten |
Date |
2003-01-28 |
Time |
18:34 |
Rev Time |
2.50 |
Received By |
lhatten |
Date |
2003-01-25 |
Time |
18:33 |
Sent To |
|
|
Notes |
2003-01-28 00:00:00 | REVIEW & STAMPED PLANS 01/25/2003 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2002-12-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-12-19 |
Time |
11:19 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
P |
|
Notes |
|
|