Plan Review Details - Permit 02121112
Plan Review Stops For Permit 02121112
Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-06-11 Cont ID  
Sent By btrobaug Date 2003-06-11 Time 13:35 Rev Time 0.33
Received By btrobaug Date 2003-06-11 Time 13:35 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-05-28 Cont ID  
Sent By btrobaug Date 2003-05-28 Time 16:12 Rev Time 0.50
Received By btrobaug Date 2003-05-28 Time 16:12 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-01-02 Cont ID  
Sent By shernand Date 2003-05-21 Time 16:55 Rev Time 0.50
Received By btrobaug Date 2002-12-31 Time 14:36 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-05-21 Cont ID  
Sent By shernand Date 2003-05-21 Time 16:55 Rev Time 0.00
Received By shernand Date 2003-05-21 Time 16:55 Sent To E
Notes
2003-05-21 00:00:00BT DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-02-04 Cont ID  
Sent By btrobaug Date 2003-02-04 Time 11:05 Rev Time 0.00
Received By btrobaug Date 2003-02-03 Time 11:05 Sent To B
Notes
2003-02-04 00:00:00TO JULIO./WRT

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-12-19 Cont ID  
Sent By dpalmer Date 2002-12-19 Time 10:50 Rev Time 0.00
Received By dpalmer Date 2002-12-19 Time 10:49 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-01-04 Cont ID  
Sent By btrobaug Date 2003-01-02 Time 13:47 Rev Time 0.50
Received By hmoser Date 2003-01-04 Time 11:16 Sent To R
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-12-28 Cont ID  
Sent By sgraham Date 2002-12-23 Time 12:59 Rev Time 0.33
Received By jleech Date 2002-12-28 Time 13:40 Sent To M
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status P Date 2003-06-24 Cont ID  
Sent By jgomez Date 2003-06-24 Time 14:42 Rev Time 0.25
Received By jgomez Date 2003-06-24 Time 14:42 Sent To  
Notes
2003-06-24 00:00:00GARAGE BOLLARD DETAIL.

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 2003-02-06 Cont ID  
Sent By jgomez Date 2003-02-06 Time 09:03 Rev Time 1.50
Received By jgomez Date 2003-02-06 Time 09:03 Sent To  
Notes
2003-02-06 00:00:00SUBMITTAL CHECKLIST:
 1-PROVIDE COMPLETE WALL SECTION FROM
 FOOTING TO CEILING FOR INTERIOR BEAR-
 ING WALL AT GARAGE. SEC. 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
 2-REVISE HANDRAIL HEIGHT SHOWN ON STAIR
 SECTION. SEE SEC. 1007.5.1 FBC 2001.
 **NOTE: HANDRAIL AND GUARDRAIL ARE NOT
 THE SAME.
 3-SPECIFY SAFETY GLASS IN 2ND FLOOR
 BATHROOM. SEC. 2405.2 FBC 2001.
 4-REVISE/CLARIFY DETAIL 4/S-2. HOW ARE
 THE TWO TRUSSES RESTING ON TOP OF THIS
 COLUMN. SEC. 104.2.1.2 CITY AMENDMENTS
 TO FBC 2001.
 **NOTE:SEE PLANS FOR ADDITIONAL COMMENTS
 AND CLARIFY CONNECTORS AS REQUIRED.
 SEE CONNECTORS LOCATION AND CLARIFY
 HOW ARE SPECIFIED CONNECTORS INSTALLED
 ON SUCH LOCATIONS.
 5-SPECIFY MISSING CONNECTORS. SEE
 FRAMING PLANS FOR COMMENTS.
 6-BUILDING SECTION A-A CALLS FOR 6"
 RECESS. FOOTING NEED TO BE 12" BELOW
 GRADE. SEC. 1804.1.3 FBC 2001. CLARIFY
 SEE SIZE OF FOOTER.
 7-VENT DRYER THRU ROOF, NOT WALL. THERE
 ARE NOT OPENINGS ALLOWED IN ZERO LOT
 LINE WALLS. TABLE 600 FBC 2001.
 8-SEE PLANS FOR COMMENTS AND RETURN
 REVIEWED DRAWINGS AFTER CORRECTIONS
 ARE DONE TO ORIGINAL CAD DRAWINGS TO
 EXPEDITE THE REVIEW PROCESS.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2003-01-28 Cont ID  
Sent By jgomez Date 2003-01-28 Time 15:08 Rev Time 2.00
Received By jgomez Date 2003-01-28 Time 15:08 Sent To  
Notes
2003-01-28 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-PROVIDE COMPLETE SECTION/DETAIL AT
 GARAGE INTERIOR BEARING WALL FROM
 FOOTING TO 2ND FLOOR CEILING. SEC.
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 2-REVISE HANDRAIL HEIGHT SHOWN ON 2ND FL
 PLAN AND STAIR SECTION. SEE SECTION
 1007.5.1 FBC 2001.
 **NOTE: HANDRAIL AND GUARDRAIL ARE NOT
 THE SAME.
 3-NEED SAFETY GLASS IN 2ND FL BATHROOM.
 SEC. 2405.2 FBC 2001.
 4-REVISE/CLARIFY DETAIL 4/S-2. FRAMING
 PLAN SHOW COLUMN RECEIVING TWO GIRDER
 TRUSSES, NOT JUST ONE. SEC. 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
 5-REVISE ROOF DIAPHRAGM FOR SHEATHING
 FASTENING ZONES ON SHEET S-3. MISSING
 SOME ZONE 3 AREAS AT THE CORNERS. SEE
 PLANS AND SEC. 2306.1 CITY AMENDMENTS
 6-2ND FLOOR AND ROOF FRAMING PLANS ARE
 MISSING SOME CONNECTORS. SEE PLANS.
 7-STORM SHUTTERS: NEED COMPLETE PRODUCT
 APPROVAL AND MARK ON APPROVED DRAWINGS
 SPECIFIC MOUNTING CONDITIONS & ANCHOR
 TYPE AND SPACING TO BE USED.
 8-REVISE DETAIL FOR 2X STRUCTURAL BUCK
 DETAIL FOR DOOR. SEE SEC. 1707.4.4.2
 FBC 2001.
 9-PROVIDE COMPLETE STRUCTURAL DETAIL FOR
 WATER HEATER PROTECTION BOLLARD. SEC.
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 10-BUILDING SECTION A-A ON SHEET A-4
 CALLS FOR 6" RECESS. CLARIFY HOW IS
 FOOTING TO BE 12" BELOW GRADE AS REQ'D
 BY SEC. 1804.1.3 FBC 2001 IF FOOTING
 IS ONLY 16" DEEP.
 11-COMPLETE SPECIFICATIONS FOR GARAGE
 DOOR STRUCTURAL BUCK. SPECIFY WASHER.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 12-USP TA20 STRAP SPECIFIED FOR (3)2X4
 COLUMN IS FOR CONCRETE APPLICATION.
 SPECIFY WOOD CONNECTOR AS REQUIRED.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 13-SHEET A-5: UPDATE CONNECTOR SPECIFIED
 ON FRAME TO CONC. BLOCK WALL DETAIL.
 SEMCO IS OUT OF BUSINESS.
 14-VENT DRYER TO ROOF. THERE ARE NOT
 OPENINGS ALLOWED ON WALL AT ZERO LOT
 LINE. TABLE 600 FBC 2001.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2003-01-28 Cont ID  
Sent By hmoser Date 2003-01-04 Time 11:16 Rev Time 4.00
Received By jgomez Date 2003-01-27 Time 16:52 Sent To  
Notes
2003-01-28 00:00:00BUILDING REVIEW CHECKLIST:
 1-PROVIDE IMPACT FEES PAID RECEIPT.
 2-PROVIDE NOTICE OF COMMENCEMENT.
 3-PROVIDE COMPLETE SECTION/DETAIL AT
 GARAGE INTERIOR BEARING WALL FROM
 FOOTING TO 2ND FLOOR CEILING. SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 4-PROVIDE SOIL TEST REPORT.
 5-REVISE HANDRAIL HEIGHT SHOWN ON 2ND FL
 PLAN AND STAIR SECTION. SEE SECTION
 1007.5.1 FBC 2001.
 **NOTE: HANDRAIL AND GUARDRAIL ARE NOT
 THE SAME.
 6-NEED SAFETY GLASS IN 2ND FL. BATHROOM.
 SEE PLANS AND SEC. 2405.2 FBC 2001.
 7-VERIFY THAT EGRESS WINDOWS SH24+5 AND
 SH34+5 PROVIDE 24" MIN. CLEAR HEIGHT &
 5.7S.F. MIN. CLEAR OPENING AS REQUIRED
 BY SEC. 1005.4.4 FBC 2001.
 8-REVISE/CLARIFY DETAIL 4/S-2. FRAMING
 PLAN SHOW COLUMN RECEIVING 2 GIRDER
 TRUSSES, NOT JUST ONE. SEC. 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
 9-REVISE ROOF DIAPHRAGM FOR SHEATHING
 FASTENING ZONES ON SHEET S-3.MISSING
 SOME ZONE 3 AREAS. SEE PLANS AND SEC.
 2306.1 CITY AMENDMENTS TO FBC 2001.
 10-ROOF FRAMING PLAN IS MISSING SOME
 CONNECTORS. SPECIFY AS REQUIRED. SEC.
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 11-PROVIDE COMPLETE INFORMATION FOR
 STORM SHUTTERS OR APPLY FOR SEPARATE
 PERMIT. SEE CITY IMPLEMENTATION
 STANDARD FOR MISSILE IMPACT PROTECTION
 12-PROVIDE PRODUCT APPROVAL FOR:
 A)ROOF TILE. (ONE SUBMITTED IS EXPIRED).
 B)ENTRY DOORS. NEED FIRST PAGE OF REPORT
 TO HAVE THE DADE COUNTY LOGO AT THE
 BOTTOM LEFT AND APPROVED DRAWINGS WITH
 DADE COUNTY APPROVAL STAMP MATCHING
 RENEWED PRODUCT APPROVAL NUMBER.
 13-REVISE ENERGY CALCULATIONS AS FOLLOWS
 A)PROVIDE COMPLETE/CORRECT ADDRESS.
 B)PROVIDE CORRECT OWNER'S INFORMATION.
 C)PROVIDE CORRECT BUILDER'S INFORMATION.
 D)COMPLETE INFORMATION ON TOP OF FORM.
 E)OWNER/AGENT TO SIGN AND DATE BOTTOM OF
 FORM ALSO.
 14-REVISE DETAIL FOR 2X STRUCTURAL BUCK
 DETAIL FOR DOOR. SEE SEC. 1707.4.4.2
 FBC 2001.
 15-PROVIDE COMPLETE STRUCTURAL DETAIL
 FOR WATER HEATER PROTECTION BOLLARD.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 16-BUILDING SECTION A-A ON SHEET A-4
 CALLS FOR 6" RECESS. CLARIFY HOW IS
 THE FOOTING GOING TO BE 12" BELOW
 GRADE AS REQUIRED BY SEC. 1804.1.3 FBC
 IF FOOTING IS ONLY 16" HIGH?
 17-COMPLETE SPECIFICATIONS FOR GARAGE
 DOOR STRUCTURAL BUCK. SPECIFY WASHERS.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 18-USP TA20 STRAP SPECIFIED FOR (3)2X4
 COLUMN IS FOR CONCRETE APPLICATION.
 PROVIDE WOOD CONNECTOR AS REQUIRED.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.

Review Stop Z ZONING
Rev No 1 Status P Date   Cont ID  
Sent By dpalmer Date 2002-12-19 Time 10:50 Rev Time 0.25
Received By sgraham Date   Time   Sent To P
Notes
***NONE***