Plan Review Stops For Permit 02121110 |
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2003-06-11 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-06-11 |
Time |
13:30 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2003-06-11 |
Time |
13:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2003-05-29 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-05-29 |
Time |
12:59 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2003-05-29 |
Time |
12:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2003-02-13 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-28 |
Time |
09:18 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2003-02-13 |
Time |
10:23 |
Sent To |
B |
|
Notes |
2003-02-13 00:00:00 | TO LOU HATTEN FOR ORGANIZING LETTERS | | AND PRODUCT APPROVALS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2003-02-06 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-02-06 |
Time |
09:23 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2003-02-06 |
Time |
09:08 |
Sent To |
|
|
Notes |
2003-02-06 00:00:00 | ************ UNSAT ************** | | | | 1)NOTE: PLEASE SEE FS/ FAC, 481.221 | | PLANS HAVE ORIG SIGNATURE BY ARCH OF | | RECORD.ALL TRADES, ALL SHEETS. | | | | PLEASE TAKE OUT OLD SHEETS AND INSERT | | NEW SHEETS FOR TWO COMPLETE SETS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2003-01-08 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2003-01-04 |
Time |
13:09 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2003-01-08 |
Time |
08:00 |
Sent To |
B |
|
Notes |
2003-01-08 00:00:00 | **************** UNSAT *************** | | | | 1)NOTE: PLEASE SEE MISSING RECEPT FOR | | KITCHEN COUNTERSPACE.210-52C1 | | | | 2)NOTE: PLEASE SEE LOAD CALCULATIONS, | | PLEASE SEE 4-SM APPL AND WASHER AT 1500W | | SHOWN AT 6KW,, PLEASE SEE 5@1500W = 7500 | | | | 3)NOTE: PLEASE ALSO NOTE ONLY TWO SMALL | | APPL CIRCUITS SHOWN ON PANEL SCHEDULE? | | 210-52/210-11C-1 | | | | 4)NOTE: PLEASE SEE LOAD CALCS, RANGE | | SHOWN AT 12KW W/ 2P50A OCP. PLEASE | | ADJUST OCP TO MEET LOAD OF RANGE. | | 12KW EXCEEDS RATING OF 50A BRKR. | | | | 5)NOTE: PLEASE SEE 2P-25A BRKR ON 10KW | | HEAT/AHU #2. PLEASE SEE 424-3B FOR | | SIZING OF OCP. MIN 125%. | | AHU#1 SHOWN W/ 60A OCP FOR SAME SIZE | | UNIT. | | | | 6)NOTE: PLEASE SEE PLANS, ALL DISC`S TO | | MEET 110-26. PLEASE NOTE. | | | | 7)NOTE: PLEASE SEE FS/FAC FOR ALL PLANS | | REQ`D TO HAVE ORIGINAL SIGNATURE, DATE | | AND SEAL. 471.025 AND 481.22 FOR ARCH | | AND ENGINEERS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-05-28 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-28 |
Time |
09:18 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-05-28 |
Time |
09:18 |
Sent To |
E |
|
Notes |
2003-05-28 00:00:00 | BT DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2002-12-19 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-12-19 |
Time |
11:20 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2002-12-19 |
Time |
11:20 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-01-04 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2003-01-04 |
Time |
07:29 |
Rev Time |
0.50 |
Received By |
hmoser |
Date |
2003-01-04 |
Time |
13:08 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2003-01-04 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2002-12-23 |
Time |
13:02 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2003-01-04 |
Time |
07:29 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2003-06-24 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2003-06-24 |
Time |
14:32 |
Rev Time |
0.25 |
Received By |
jgomez |
Date |
2003-06-24 |
Time |
14:32 |
Sent To |
|
|
Notes |
2003-06-24 00:00:00 | GARAGE BOLLARD DETAIL. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2003-01-28 |
|
|
Cont ID |
|
Sent By |
lhatten |
Date |
2003-01-28 |
Time |
18:20 |
Rev Time |
2.50 |
Received By |
lhatten |
Date |
2003-01-26 |
Time |
18:19 |
Sent To |
|
|
Notes |
2003-01-28 00:00:00 | REVIEW & STAMPED PLANS 01/26/2003 | | PRINT CARD 01/28/2003 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2002-12-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-12-19 |
Time |
11:20 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
P |
|
Notes |
|
|