Plan Review Stops For Permit 02120870 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2003-01-17 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2003-01-17 |
Time |
15:17 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2003-01-17 |
Time |
15:17 |
Sent To |
|
|
Notes |
2003-01-17 00:00:00 | BUILDING PLAN REVIEW | | ******PROVISO******* | | ROBERT BROWN(561) 659 8096 EXT 8499 | | | | FBC = FLORIDA BUILDING CODE 2001 | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | --PROVISO-- | | THE PARTITION WALL TO THE PRIVATE DINING | | AREAS APPEARS TO BE EXISTING AND | | UNALTERED.IF THIS ASSUMPTION IS NOT | | CORRECT A SEPARATE PERMIT APPLICATION | | WILL BE REQUIRED. | | | | --PROVISO-- | | FBC 11-4.5THE NEW FLOOR SURFACE SHALL | | BE STABLE, FIRM AND SLIP-RESISTANT TO | | MAINTAIN ACCESSIBILITY. | | | | --PROVISO-- | | FBC 2405.2THE GLAZING IN THE FRENCH | | DOORS AND ANY IN THE NEW KITCHEN DOOR IS | | REQUIRED TO BE SAFETY GLASS SATISFYING | | THE REQUIREMENTS OF THE CONSUMER PRODUCT | | SAFETY COMMISSION 16, CODE OF FEDERAL | | REGULATIONS, PART 1201 (CPSC 16-CFR, | | PART 1201).SUBMIT DETAILS TO | | DEMONSTRATE COMPLIANCE. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2003-02-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-02-07 |
Time |
16:37 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2003-02-07 |
Time |
16:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2002-12-30 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-12-30 |
Time |
06:27 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2002-12-30 |
Time |
06:27 |
Sent To |
|
|
Notes |
2002-12-30 00:00:00 | PLEASE SEE ANY FIRE REVIEW COMMENTS | | THAT MAY AFFECT ELECTRICAL SHEETS | | FOR CLARIFICATION OF NEW/EXSITING EXIT | | AND EMERGENCY LTS. | | PLEASE NOTE ANY CHANGE MAY BE REQ`D TO | | MEET 700-12. | | | | IF THERE ARE ANY QUESTIONS,PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2003-02-13 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2003-02-13 |
Time |
14:57 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2003-02-13 |
Time |
14:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2003-01-03 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2003-01-03 |
Time |
09:33 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2003-01-03 |
Time |
09:32 |
Sent To |
|
|
Notes |
2003-01-03 00:00:00 | 1) PLEASE INDICATE WHAT THE INTERIOR | | FINISH OF THE WALLS AND CEILINGS WILL | | BE. | | | | 2) PLEASE INDICATE LOCATIONS OF | | ANY PORTABLE FIRE EXTINGUISHERS. | | | | 3) PLEASE INDICATE OCCUPANT LOADS | | INCLUDING STAFF RATIO'S. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-02-06 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-02-06 |
Time |
16:42 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2003-02-06 |
Time |
16:42 |
Sent To |
|
|
Notes |
2003-02-06 00:00:00 | TO COMM BOARD #57 ALL NEW SHEETS. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2002-12-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-12-23 |
Time |
10:44 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2002-12-23 |
Time |
10:44 |
Sent To |
|
|
Notes |
2002-12-23 00:00:00 | TO #29 ON COMM BOARD. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2003-02-13 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-02-13 |
Time |
13:16 |
Rev Time |
0.30 |
Received By |
pkrauss |
Date |
2003-02-13 |
Time |
13:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-01-06 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-01-06 |
Time |
08:31 |
Rev Time |
0.55 |
Received By |
pkrauss |
Date |
2003-01-06 |
Time |
08:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2003-02-06 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-02-06 |
Time |
16:43 |
Rev Time |
0.75 |
Received By |
kstevens |
Date |
2003-02-06 |
Time |
14:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2003-01-11 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-01-11 |
Time |
09:00 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2003-01-11 |
Time |
08:59 |
Sent To |
|
|
Notes |
2003-01-11 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 11 | | | | 1) PLEASE PROVIDE A WATER RISER DIAGRAM. | | | | 2) SECTION 11-4.1.6(2) REQUIRES THAT 20% | | OVER CONTRACT PRICE SHALL BE SPENT ON | | ACCESSIBILITY. PLEASE SHOW HOW $4,300 | | WILL BE SPENT. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|
|