Plan Review Details - Permit 02120870
Plan Review Stops For Permit 02120870
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-01-17 Cont ID  
Sent By rbrown Date 2003-01-17 Time 15:17 Rev Time 0.00
Received By rbrown Date 2003-01-17 Time 15:17 Sent To  
Notes
2003-01-17 00:00:00BUILDING PLAN REVIEW
 ******PROVISO*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
  
 --PROVISO--
 THE PARTITION WALL TO THE PRIVATE DINING
 AREAS APPEARS TO BE EXISTING AND
 UNALTERED.IF THIS ASSUMPTION IS NOT
 CORRECT A SEPARATE PERMIT APPLICATION
 WILL BE REQUIRED.
  
 --PROVISO--
 FBC 11-4.5THE NEW FLOOR SURFACE SHALL
 BE STABLE, FIRM AND SLIP-RESISTANT TO
 MAINTAIN ACCESSIBILITY.
  
 --PROVISO--
 FBC 2405.2THE GLAZING IN THE FRENCH
 DOORS AND ANY IN THE NEW KITCHEN DOOR IS
 REQUIRED TO BE SAFETY GLASS SATISFYING
 THE REQUIREMENTS OF THE CONSUMER PRODUCT
 SAFETY COMMISSION 16, CODE OF FEDERAL
 REGULATIONS, PART 1201 (CPSC 16-CFR,
 PART 1201).SUBMIT DETAILS TO
 DEMONSTRATE COMPLIANCE.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-02-07 Cont ID  
Sent By dpalmer Date 2003-02-07 Time 16:37 Rev Time 0.25
Received By dpalmer Date 2003-02-07 Time 16:37 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-12-30 Cont ID  
Sent By dpalmer Date 2002-12-30 Time 06:27 Rev Time 0.25
Received By dpalmer Date 2002-12-30 Time 06:27 Sent To  
Notes
2002-12-30 00:00:00PLEASE SEE ANY FIRE REVIEW COMMENTS
 THAT MAY AFFECT ELECTRICAL SHEETS
 FOR CLARIFICATION OF NEW/EXSITING EXIT
 AND EMERGENCY LTS.
 PLEASE NOTE ANY CHANGE MAY BE REQ`D TO
 MEET 700-12.
  
 IF THERE ARE ANY QUESTIONS,PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2003-02-13 Cont ID  
Sent By mcarsill Date 2003-02-13 Time 14:57 Rev Time 0.00
Received By mcarsill Date 2003-02-13 Time 14:57 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2003-01-03 Cont ID  
Sent By mcarsill Date 2003-01-03 Time 09:33 Rev Time 0.00
Received By mcarsill Date 2003-01-03 Time 09:32 Sent To  
Notes
2003-01-03 00:00:001) PLEASE INDICATE WHAT THE INTERIOR
 FINISH OF THE WALLS AND CEILINGS WILL
 BE.
  
 2) PLEASE INDICATE LOCATIONS OF
 ANY PORTABLE FIRE EXTINGUISHERS.
  
 3) PLEASE INDICATE OCCUPANT LOADS
 INCLUDING STAFF RATIO'S.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT.8497
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-02-06 Cont ID  
Sent By dpalmer Date 2003-02-06 Time 16:42 Rev Time 0.00
Received By dpalmer Date 2003-02-06 Time 16:42 Sent To  
Notes
2003-02-06 00:00:00TO COMM BOARD #57 ALL NEW SHEETS.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-12-23 Cont ID  
Sent By dpalmer Date 2002-12-23 Time 10:44 Rev Time 0.00
Received By dpalmer Date 2002-12-23 Time 10:44 Sent To  
Notes
2002-12-23 00:00:00TO #29 ON COMM BOARD.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-02-13 Cont ID  
Sent By pkrauss Date 2003-02-13 Time 13:16 Rev Time 0.30
Received By pkrauss Date 2003-02-13 Time 13:14 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-01-06 Cont ID  
Sent By pkrauss Date 2003-01-06 Time 08:31 Rev Time 0.55
Received By pkrauss Date 2003-01-06 Time 08:31 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-02-06 Cont ID  
Sent By kstevens Date 2003-02-06 Time 16:43 Rev Time 0.75
Received By kstevens Date 2003-02-06 Time 14:40 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-01-11 Cont ID  
Sent By kstevens Date 2003-01-11 Time 09:00 Rev Time 0.50
Received By kstevens Date 2003-01-11 Time 08:59 Sent To  
Notes
2003-01-11 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 11
  
 1) PLEASE PROVIDE A WATER RISER DIAGRAM.
  
 2) SECTION 11-4.1.6(2) REQUIRES THAT 20%
 OVER CONTRACT PRICE SHALL BE SPENT ON
 ACCESSIBILITY. PLEASE SHOW HOW $4,300
 WILL BE SPENT.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377