Plan Review Details - Permit 02120762
Plan Review Stops For Permit 02120762
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-02-21 Cont ID  
Sent By hpiskura Date 2003-02-21 Time 07:09 Rev Time 0.00
Received By hpiskura Date 2003-02-21 Time 07:09 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-02-10 Cont ID  
Sent By hpiskura Date 2003-02-10 Time 08:54 Rev Time 0.00
Received By hpiskura Date 2003-02-10 Time 08:37 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-01-14 Cont ID  
Sent By lsmith Date 2003-01-14 Time 13:49 Rev Time 1.00
Received By lsmith Date   Time   Sent To  
Notes
2003-01-14 00:00:0050' DEAD END CORRIDOR OK PER FBC TABLE
 1004 NOTE 20

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-02-21 Cont ID  
Sent By dpalmer Date 2003-02-21 Time 06:32 Rev Time 0.33
Received By dpalmer Date 2003-02-21 Time 06:32 Sent To  
Notes
2003-02-21 00:00:00************** NOTES REDLINED *******
  
 PLEASE VERIFY AND SIZE ALL OCP AND
 WIRE SIZES FOR A/C UNITS PER MANUFACT.
 NAMEPLATE AND NEC. PANEL SCHEDULE SHOWS
 100A OCP ON #6,,,ETC.
  
  
 PLEASE REVISE BEFORE FINAL AND SUBMIT
 FOR REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2003-02-04 Cont ID  
Sent By dpalmer Date 2003-02-04 Time 16:19 Rev Time 1.00
Received By dpalmer Date 2003-02-04 Time 16:19 Sent To  
Notes
2003-02-04 00:00:00************ UNSAT ************
  
 PLEASE NOTE, SOME NOTED FROM FIRST
 REVIEW, WERE NOT ADDRESSED.
  
 1)NOTE: PLEASE SEE OCP FOR SERVICE
 ENTRANCE CONDUCTORS TO NEXT HIGHEST
 STANDARD RATING. CONDUCTORS SHOWN ARE
 RATED FOR 285, SERVICE IS SIZED AT 400A
 `S. PLEASE ADJUST. 240-3
  
 2)NOTE: PLEASE SEE 250-24, AN EQUIPMENT
 GROUNDING CONDUCTOR IS ONLY INSTALLED
 AFTER FIRST MEANS OF DISC, PANEL DETAIL
 SHOWS A #6 TO PANEL.
  
 3)NOTE: PLEASE SHOW LOAD CALCUALTIONS
 PER 220-3,-10,-11, -13, ETC. PLEASE SHOW
 W/PER SQ FT, RECEPTS ETC, PLEASE ALSO
 CLARIFY LOAD SHOWN ON 20A OCP FOR TRK
 LIGHTING. SHOWN AT 2500 WATTS WHICH
 EXCEED 80% LOADING OF BRKR.
  
 4)NOTE: PLEASE SEE SIZING OF OCP FOR
 RTU'S AND AHU PER 424-3
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-12-27 Cont ID  
Sent By dpalmer Date 2002-12-27 Time 18:22 Rev Time 0.50
Received By dpalmer Date 2002-12-27 Time 18:22 Sent To  
Notes
2002-12-27 00:00:00************* UNSAT *************
  
 1)NOTE: PLEASE CLARIFY/SHOW NEW OR
 EXISTING SHOW WINDOW RECEPTS 210-62
  
 2)NOTE: PLEASE CLARIFY NEW OR EXISTING
 SIGN CIRCUTI PER 600-5
  
 3)NOTE: PLEASE SIZE SERVICE ENTRANCE
 CONDUCTORS PER 310-16/110-14 PLEASE NOTE
 300MCM IS ONLY RATED FOR 285A'S.
  
 4)NOTE: PLEASE VERIFY AND SHOW LOAD
 CALCUALTIONS PER NEC 220. PLEASE NOTE
 TWO LOADS ARE SHOWN. ONE SHOWN EXCEEDS
 300MCM OTHER ??
  
 5)NOTE: PLEASE SHOW TRACK LT CALCUALTION
 S PER 220-12 AND VERIFY TRK. MOST TRK
 IS RATED AT 20A MAX. PANEL SCHEDULE
 SHOWS 25A OCP???
  
 6)NOTE: PLEASE CLARIFY FIRE PUMP AND
 HOW IT IS FED NOW THAT NEW SERVICE IS
 BEING DONE. EVEN IF NO WORK IN AREA,
 PLEASE EXPLAIN WHERE FIRE PUMP IS FED
 FROM..
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2003-01-10 Cont ID  
Sent By mcarsill Date 2003-01-10 Time 13:31 Rev Time 0.00
Received By mcarsill Date 2003-01-10 Time 13:31 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-02-20 Cont ID  
Sent By dpalmer Date 2003-02-20 Time 09:01 Rev Time 0.00
Received By dpalmer Date 2003-02-20 Time 09:01 Sent To  
Notes
2003-02-20 00:00:00TO COMM BOARD #29

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-12-12 Cont ID  
Sent By btrobaug Date 2002-12-12 Time 13:20 Rev Time 0.00
Received By btrobaug Date 2002-12-12 Time 13:20 Sent To  
Notes
2002-12-12 00:00:00TO COMM BOARD # 2./WRT.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2003-01-06 Cont ID  
Sent By pkrauss Date 2003-01-06 Time 14:44 Rev Time 0.20
Received By pkrauss Date 2003-01-06 Time 14:44 Sent To  
Notes
2003-01-06 00:00:00NO MECHANICAL PLANS SUBMITTED FOR REVIEW
  
 NOTE ON PERMIT APPLICATION INDICATES
 MECHANICAL CONTRACTOR TO SUBMIT PLANS
 WITH MECHANICAL PERMIT APPLICATION.

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-03-04 Cont ID  
Sent By kstevens Date 2003-03-04 Time 09:43 Rev Time 1.50
Received By kstevens Date 2003-03-04 Time 09:42 Sent To  
Notes
2003-03-04 00:00:00PASSED/PROVISO
  
 THERMAL EXPANSION TANK REQUIRED ON WATER
 HEATER.
  
 SHOWER UNIT REQUIRED PER 11-4.21.6

Review Stop P PLUMBING
Rev No 2 Status F Date 2003-02-08 Cont ID  
Sent By kstevens Date 2003-02-08 Time 06:01 Rev Time 0.75
Received By kstevens Date 2003-02-08 Time 06:00 Sent To  
Notes
2003-02-08 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 11
  
 1) RESPONSE NOTED FOR SEPARATE FACILIT-
 IES, BUT DATA ON SHT A-1 STILL CALLS FOR
 EXCEPTION #4. PLEASE CHANGE DATA TO CALL
 OUT FOR EXCEPTION #2 AND INDICATE NUMBER
 OF PEOPLE THAT WILL BE EMPLOYED AS IN-
 DICATED IN SECTION 403.2
 2) RESPONSE NOTED FOR BOTTLED WATER.
 PLEASE SHOW ON PLANS. WATER COOLER SHALL
 BE ARI-1010 COMPLIANT PER 410.1. MANUF.
 INFORMATION REQUIRED.
 3) SHT P-1 VACUUM RELIEF VALVE IS NOT
 FOR THERMAL EXPANSION CONTROL. AN EXPAN-
 SION TANK IS REQUIRED AT WATER HEATER.
 4) SHT A-2 SHOWER DOES NOT COMPLY WITH
 11-4.21.2 ( SHOWER STALL SIZE AND CLEAR
 FLOOR SPACE SHALL COMPLY WITH FIG. 35(A)
 OR (B). NO DETAILS FOR SEAT HEIGHT 11-4.
 21.3, GRAB BARS 11-4.21.4, CONTROLS 11-
 4.21.5, SHOWER UNIT 11-4.21.6, OR CURBS
 1104.21.7 ARE NOT SHOWN. PLEASE PROVIDE
 DETAILS FOR SHOWER.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-01-06 Cont ID  
Sent By kstevens Date 2003-01-06 Time 07:43 Rev Time 1.50
Received By kstevens Date 2002-12-31 Time 11:41 Sent To  
Notes
2003-01-06 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 11
  
 1) SHT A-1 RESTROOM #118 MINIMUM WIDTH
 FOR HDCP RESTROOM IS 5'3", BUT 5'2" IS
 SHOWN ON PLANS.
 2) SHT A-1 BLDG. DATA SHOWS 3,700 SQ FT
 SECTION 403.2 REQUIRES 2 FIXTURES UNLESS
 3000 SQ FT OR LESS. TABLE REQUIRES SEP-
 ARATE FACILITIES FOR MEN AND WOMEN. EACH
 RESTROOM SHALL BE ACCESSIBLE. PLEASE
 SHOW 5' TURNING RADIUS AND CLEAR FLOOR
 SPACE FOR EACH RESTROOM.
 3) TABLE 403.1 REQUIRES A DRINKING
 FOUNTAIN. ALSO SEE SECTION 410.1.
 4) SHT P-1 WATER HEATER DETAIL, THERMAL
 EXPANSION PROTECTION REQUIRED PER SECT-
 ION 607.3.2. PLEASE SHOW ON DETAIL
 5) SHTP-1 DOMESTIC WATER ISOMETRIC,
 WATER HAMMER ARRESTORS REQUIRED BY SEC
 604.9 SHALL BE LOCATED NEAR THE FIXTURE
 IN AN "EFFECTIVE RANGE" NOT AT THE TOP
 OF THE DROP IN CEILING AS SHOWN.
 6) DETAIL REQUIRED FOR SHOWER SHOWING
 COMPLIANCE WITH SECTION 11-4.21 AND ALL
 SUBSECTIONS.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377