Plan Review Stops For Permit 02120762 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2003-02-21 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
2003-02-21 |
Time |
07:09 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
2003-02-21 |
Time |
07:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2003-02-10 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
2003-02-10 |
Time |
08:54 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
2003-02-10 |
Time |
08:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2003-01-14 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2003-01-14 |
Time |
13:49 |
Rev Time |
1.00 |
Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2003-01-14 00:00:00 | 50' DEAD END CORRIDOR OK PER FBC TABLE | | 1004 NOTE 20 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2003-02-21 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-02-21 |
Time |
06:32 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2003-02-21 |
Time |
06:32 |
Sent To |
|
|
Notes |
2003-02-21 00:00:00 | ************** NOTES REDLINED ******* | | | | PLEASE VERIFY AND SIZE ALL OCP AND | | WIRE SIZES FOR A/C UNITS PER MANUFACT. | | NAMEPLATE AND NEC. PANEL SCHEDULE SHOWS | | 100A OCP ON #6,,,ETC. | | | | | | PLEASE REVISE BEFORE FINAL AND SUBMIT | | FOR REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2003-02-04 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-02-04 |
Time |
16:19 |
Rev Time |
1.00 |
Received By |
dpalmer |
Date |
2003-02-04 |
Time |
16:19 |
Sent To |
|
|
Notes |
2003-02-04 00:00:00 | ************ UNSAT ************ | | | | PLEASE NOTE, SOME NOTED FROM FIRST | | REVIEW, WERE NOT ADDRESSED. | | | | 1)NOTE: PLEASE SEE OCP FOR SERVICE | | ENTRANCE CONDUCTORS TO NEXT HIGHEST | | STANDARD RATING. CONDUCTORS SHOWN ARE | | RATED FOR 285, SERVICE IS SIZED AT 400A | | `S. PLEASE ADJUST. 240-3 | | | | 2)NOTE: PLEASE SEE 250-24, AN EQUIPMENT | | GROUNDING CONDUCTOR IS ONLY INSTALLED | | AFTER FIRST MEANS OF DISC, PANEL DETAIL | | SHOWS A #6 TO PANEL. | | | | 3)NOTE: PLEASE SHOW LOAD CALCUALTIONS | | PER 220-3,-10,-11, -13, ETC. PLEASE SHOW | | W/PER SQ FT, RECEPTS ETC, PLEASE ALSO | | CLARIFY LOAD SHOWN ON 20A OCP FOR TRK | | LIGHTING. SHOWN AT 2500 WATTS WHICH | | EXCEED 80% LOADING OF BRKR. | | | | 4)NOTE: PLEASE SEE SIZING OF OCP FOR | | RTU'S AND AHU PER 424-3 | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2002-12-27 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-12-27 |
Time |
18:22 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2002-12-27 |
Time |
18:22 |
Sent To |
|
|
Notes |
2002-12-27 00:00:00 | ************* UNSAT ************* | | | | 1)NOTE: PLEASE CLARIFY/SHOW NEW OR | | EXISTING SHOW WINDOW RECEPTS 210-62 | | | | 2)NOTE: PLEASE CLARIFY NEW OR EXISTING | | SIGN CIRCUTI PER 600-5 | | | | 3)NOTE: PLEASE SIZE SERVICE ENTRANCE | | CONDUCTORS PER 310-16/110-14 PLEASE NOTE | | 300MCM IS ONLY RATED FOR 285A'S. | | | | 4)NOTE: PLEASE VERIFY AND SHOW LOAD | | CALCUALTIONS PER NEC 220. PLEASE NOTE | | TWO LOADS ARE SHOWN. ONE SHOWN EXCEEDS | | 300MCM OTHER ?? | | | | 5)NOTE: PLEASE SHOW TRACK LT CALCUALTION | | S PER 220-12 AND VERIFY TRK. MOST TRK | | IS RATED AT 20A MAX. PANEL SCHEDULE | | SHOWS 25A OCP??? | | | | 6)NOTE: PLEASE CLARIFY FIRE PUMP AND | | HOW IT IS FED NOW THAT NEW SERVICE IS | | BEING DONE. EVEN IF NO WORK IN AREA, | | PLEASE EXPLAIN WHERE FIRE PUMP IS FED | | FROM.. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2003-01-10 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2003-01-10 |
Time |
13:31 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2003-01-10 |
Time |
13:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-02-20 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-02-20 |
Time |
09:01 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2003-02-20 |
Time |
09:01 |
Sent To |
|
|
Notes |
2003-02-20 00:00:00 | TO COMM BOARD #29 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2002-12-12 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-12-12 |
Time |
13:20 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2002-12-12 |
Time |
13:20 |
Sent To |
|
|
Notes |
2002-12-12 00:00:00 | TO COMM BOARD # 2./WRT. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2003-01-06 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-01-06 |
Time |
14:44 |
Rev Time |
0.20 |
Received By |
pkrauss |
Date |
2003-01-06 |
Time |
14:44 |
Sent To |
|
|
Notes |
2003-01-06 00:00:00 | NO MECHANICAL PLANS SUBMITTED FOR REVIEW | | | | NOTE ON PERMIT APPLICATION INDICATES | | MECHANICAL CONTRACTOR TO SUBMIT PLANS | | WITH MECHANICAL PERMIT APPLICATION. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2003-03-04 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-03-04 |
Time |
09:43 |
Rev Time |
1.50 |
Received By |
kstevens |
Date |
2003-03-04 |
Time |
09:42 |
Sent To |
|
|
Notes |
2003-03-04 00:00:00 | PASSED/PROVISO | | | | THERMAL EXPANSION TANK REQUIRED ON WATER | | HEATER. | | | | SHOWER UNIT REQUIRED PER 11-4.21.6 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2003-02-08 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-02-08 |
Time |
06:01 |
Rev Time |
0.75 |
Received By |
kstevens |
Date |
2003-02-08 |
Time |
06:00 |
Sent To |
|
|
Notes |
2003-02-08 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 11 | | | | 1) RESPONSE NOTED FOR SEPARATE FACILIT- | | IES, BUT DATA ON SHT A-1 STILL CALLS FOR | | EXCEPTION #4. PLEASE CHANGE DATA TO CALL | | OUT FOR EXCEPTION #2 AND INDICATE NUMBER | | OF PEOPLE THAT WILL BE EMPLOYED AS IN- | | DICATED IN SECTION 403.2 | | 2) RESPONSE NOTED FOR BOTTLED WATER. | | PLEASE SHOW ON PLANS. WATER COOLER SHALL | | BE ARI-1010 COMPLIANT PER 410.1. MANUF. | | INFORMATION REQUIRED. | | 3) SHT P-1 VACUUM RELIEF VALVE IS NOT | | FOR THERMAL EXPANSION CONTROL. AN EXPAN- | | SION TANK IS REQUIRED AT WATER HEATER. | | 4) SHT A-2 SHOWER DOES NOT COMPLY WITH | | 11-4.21.2 ( SHOWER STALL SIZE AND CLEAR | | FLOOR SPACE SHALL COMPLY WITH FIG. 35(A) | | OR (B). NO DETAILS FOR SEAT HEIGHT 11-4. | | 21.3, GRAB BARS 11-4.21.4, CONTROLS 11- | | 4.21.5, SHOWER UNIT 11-4.21.6, OR CURBS | | 1104.21.7 ARE NOT SHOWN. PLEASE PROVIDE | | DETAILS FOR SHOWER. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2003-01-06 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-01-06 |
Time |
07:43 |
Rev Time |
1.50 |
Received By |
kstevens |
Date |
2002-12-31 |
Time |
11:41 |
Sent To |
|
|
Notes |
2003-01-06 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 11 | | | | 1) SHT A-1 RESTROOM #118 MINIMUM WIDTH | | FOR HDCP RESTROOM IS 5'3", BUT 5'2" IS | | SHOWN ON PLANS. | | 2) SHT A-1 BLDG. DATA SHOWS 3,700 SQ FT | | SECTION 403.2 REQUIRES 2 FIXTURES UNLESS | | 3000 SQ FT OR LESS. TABLE REQUIRES SEP- | | ARATE FACILITIES FOR MEN AND WOMEN. EACH | | RESTROOM SHALL BE ACCESSIBLE. PLEASE | | SHOW 5' TURNING RADIUS AND CLEAR FLOOR | | SPACE FOR EACH RESTROOM. | | 3) TABLE 403.1 REQUIRES A DRINKING | | FOUNTAIN. ALSO SEE SECTION 410.1. | | 4) SHT P-1 WATER HEATER DETAIL, THERMAL | | EXPANSION PROTECTION REQUIRED PER SECT- | | ION 607.3.2. PLEASE SHOW ON DETAIL | | 5) SHTP-1 DOMESTIC WATER ISOMETRIC, | | WATER HAMMER ARRESTORS REQUIRED BY SEC | | 604.9 SHALL BE LOCATED NEAR THE FIXTURE | | IN AN "EFFECTIVE RANGE" NOT AT THE TOP | | OF THE DROP IN CEILING AS SHOWN. | | 6) DETAIL REQUIRED FOR SHOWER SHOWING | | COMPLIANCE WITH SECTION 11-4.21 AND ALL | | SUBSECTIONS. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|
|