Plan Review Details - Permit 02120308
Plan Review Stops For Permit 02120308
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-05-29 Cont ID  
Sent By btrobaug Date 2003-05-29 Time 13:16 Rev Time 0.50
Received By btrobaug Date 2003-05-29 Time 13:16 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-12-31 Cont ID  
Sent By shernand Date 2003-05-28 Time 09:19 Rev Time 0.50
Received By btrobaug Date 2002-12-31 Time 10:26 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-05-28 Cont ID  
Sent By shernand Date 2003-05-28 Time 09:19 Rev Time 0.00
Received By shernand Date 2003-05-28 Time 09:19 Sent To E
Notes
2003-05-28 00:00:00BT DESK

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-02-04 Cont ID  
Sent By dpalmer Date 2003-02-04 Time 10:09 Rev Time 0.00
Received By dpalmer Date 2003-02-04 Time 10:09 Sent To B
Notes
2003-02-04 00:00:00TO ROBERT MC DOUGAL'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-01-24 Cont ID  
Sent By dpalmer Date 2003-01-24 Time 12:12 Rev Time 0.00
Received By dpalmer Date 2003-01-24 Time 12:12 Sent To B
Notes
2003-01-24 00:00:00TO ROBERT MCDOUGAL'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2002-12-19 Cont ID  
Sent By dpalmer Date 2002-12-19 Time 09:41 Rev Time 0.00
Received By dpalmer Date 2002-12-19 Time 09:41 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-12-09 Cont ID  
Sent By btrobaug Date 2002-12-09 Time 13:17 Rev Time 0.00
Received By btrobaug Date 2002-12-04 Time 13:17 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-02-04 Cont ID  
Sent By pkrauss Date 2003-02-04 Time 15:03 Rev Time 0.30
Received By pkrauss Date 2003-02-04 Time 15:03 Sent To  
Notes
2003-02-04 00:00:00PROVISO:MECHANICAL PERMIT 02120493
  
 AUXILIARY DRAIN PANS WITH OVERFLOW
 PROTECTION ARE REQUIRED UNDER ALL COILS
 WHERE OVERFLOW COULD CAUSE DAMAGE TO THE
 BUILDING OR ITS CONTENTS.
  
 PLEASE NOTE PLAN IDICATES A 5 TON UNIT
 ON THE 1ST & 2ND FLOOR.SCHEDULE SHOWS
 TWO 3 TON UNITS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2003-01-04 Cont ID  
Sent By btrobaug Date 2002-12-31 Time 10:42 Rev Time 0.25
Received By hmoser Date 2003-01-04 Time 08:36 Sent To R
Notes
2003-01-04 00:00:00NO PLANS
 01/04/03 H.M.

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-12-28 Cont ID  
Sent By sgraham Date 2002-12-23 Time 12:49 Rev Time 0.25
Received By jleech Date 2002-12-28 Time 12:19 Sent To M
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2003-02-04 Cont ID  
Sent By rmcdouga Date 2003-02-04 Time 15:14 Rev Time 3.00
Received By rmcdouga Date   Time   Sent To  
Notes
2003-02-04 00:00:00BUILDING PROVISO
  
 1)PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - SINGLE HUNG WINDOWS
 - ARCHED FIXED GLASS WINDOWS

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2003-01-31 Cont ID  
Sent By rmcdouga Date 2003-01-31 Time 10:48 Rev Time 3.00
Received By rmcdouga Date   Time   Sent To  
Notes
2003-01-31 00:00:00BUILDING DENIED
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) PROVIDE A SOIL TEST FROM A SOIL
 ENGINEER AS REQUIRED BY FBC 1804.2.
  
 3) THE CONDITIONED AREA LISTED ON THE
 ENERGY CALCS. (3414 SQFT) DOES NOT MATCH
 THE A/C AREA (3101 SQFT) LISTED ON THE
 PLANS. PLEASE CORRECT.
  
 4)PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - SINGLE HUNG WINDOWS
 - ARCHED FIXED GLASS WINDOWS
 NOTE: THE PRODUCT APPROVALS FOR THE ROOF
 TILE EXPIRED ON 12/16/02.
  
 (5) THE HURRICANE PANEL KEY PLAN AND
 INSTALLATION SCHEDULE DOES NOT MATCH THE
 STRUCTURE. THE ONE SUBMITTED IS FOR A
 ONE STORY BUILDING. PLEASE SUBMIT THE
 CORRECT ONES.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2003-01-10 Cont ID  
Sent By hmoser Date 2003-01-04 Time 08:36 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2003-01-10 00:00:00BUILDING DENIED
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) FL BLD CODE 1804.2.2 QUESTIONABLE
 SOILS, WHERE THE BEARING CAPACITY IS
 NOT DEFINETLY KNOWN OR IS IN QUESTION.
 PROVIDE SOIL REPORT.
  
 3) DRYER VENT CAN NOT PENETRATE THROUGH
 THE ONE HOUR FIRE RATED WALL ON THE
 ZERO LOT LINE. TABLE 600 OF THE FBC DOES
 NOT ALLOW ANY OPENINGS IN A WALL WITHIN
 THREE FEET OF THE PROPERTY LINE.
  
 4) SECTION 2 ONS1 IS MISLABELED AS 2
 ON S2. PLEASE CORRECT.
  
 5) THE USP TA24 CONNECTORS SPECIFIED ON
 S2 FOR THE TRUSSES AT THE COVERED PORCH
 AND ON THE BUILDING SECTION ON A4 FOR
 THE ATTACHMENT OF FLOOR TRUSSES TO THE
 LEDGER ARE NOT THE PROPER ANCHORS. THESE
 ARE EMBED TYPE ANCHORS AND NOT WOOD TO
 WOOD STRAPS. PLEASE CORRECT.
  
 6) PROVIDE ADDITIONAL DETAILS FOR THE
 WOOD DECK ABOVE THE ENTRY. INDICATE THE
 CONNECTORS FOR THE 2X10 JOISTS, THE
 SHEATHING, ROOF COVERING MATERIAL, ETC.
  
 7) THE ENERGY CALCULATIONS ARE REQUIRED
 TO BE SIGNED BY THE OWNER/AGENT. THE
 CONDITION SPACE ON THE ENERGY CALC. FORM
 DOES NOT AGREE WITH THE A/C AREA LISTED
 ON THE PLANS. PLEASE CORRECT.
  
 8) THE STORM PANEL INSTALLATION
 SCHEDULE AND KEY PLAN SUBMITTED DOES NOT
 CORRESPOND TO THIS MODEL.
  
 9) PROVIDE A STRUCTURAL DETAIL FOR THE
 BOLLARD USED TO PROTECT THE WATER HEATER
 IN THE GARAGE.
  
 10) PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - SLIDING GLASS DOORS
 - SINGLE HUNG WINDOWS
 - ARCHED FIXED GLASS WINDOWS
 NOTE: PRODUCT APPROVAL FOR ROOF TILE
 EXPIRED ON 12/16/02.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop Z ZONING
Rev No 2 Status P Date 2002-12-23 Cont ID  
Sent By sgraham Date 2002-12-23 Time 12:49 Rev Time 0.25
Received By sgraham Date   Time   Sent To P
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2002-12-13 Cont ID  
Sent By btrobaug Date 2002-12-09 Time 13:17 Rev Time 0.25
Received By sgraham Date   Time   Sent To P
Notes
2002-12-13 00:00:00DENIED NEED SITE PLAN