Plan Review Details - Permit 02120306
Plan Review Stops For Permit 02120306
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-05-29 Cont ID  
Sent By btrobaug Date 2003-05-29 Time 13:55 Rev Time 0.50
Received By btrobaug Date 2003-05-29 Time 13:33 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-12-31 Cont ID  
Sent By shernand Date 2003-05-28 Time 09:20 Rev Time 0.50
Received By btrobaug Date 2002-12-31 Time 10:43 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-05-28 Cont ID  
Sent By shernand Date 2003-05-28 Time 09:20 Rev Time 0.00
Received By shernand Date 2003-05-28 Time 09:20 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-02-03 Cont ID  
Sent By btrobaug Date 2003-02-03 Time 18:09 Rev Time 0.00
Received By btrobaug Date 2003-02-03 Time 18:08 Sent To B
Notes
2003-02-03 00:00:00TO ROB M./WRT.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-01-24 Cont ID  
Sent By dpalmer Date 2003-01-24 Time 12:11 Rev Time 0.00
Received By dpalmer Date 2003-01-24 Time 12:11 Sent To B
Notes
2003-01-24 00:00:00TO ROBERT MCDOUGAL'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2002-12-19 Cont ID  
Sent By dpalmer Date 2002-12-19 Time 09:40 Rev Time 0.00
Received By dpalmer Date 2002-12-19 Time 09:40 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-12-09 Cont ID  
Sent By btrobaug Date 2002-12-09 Time 13:16 Rev Time 0.00
Received By btrobaug Date 2002-12-04 Time 13:16 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-01-31 Cont ID  
Sent By pkrauss Date 2003-01-31 Time 13:48 Rev Time 0.40
Received By pkrauss Date 2003-01-31 Time 13:48 Sent To  
Notes
2003-01-31 00:00:00PROVISO:MECHANICAL PERMIT 02120498
  
 FAN SHUTDOWN REQUIRED AT FINAL
 INSPECTION

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2003-01-04 Cont ID  
Sent By btrobaug Date 2002-12-31 Time 11:19 Rev Time 0.25
Received By hmoser Date 2003-01-04 Time 08:16 Sent To R
Notes
2003-01-04 00:00:00NO MECHANICAL PLANS H.M.1/04/03

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-12-28 Cont ID  
Sent By sgraham Date 2002-12-23 Time 12:57 Rev Time 0.25
Received By jleech Date 2002-12-28 Time 12:32 Sent To M
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2003-02-05 Cont ID  
Sent By rmcdouga Date 2003-02-04 Time 14:26 Rev Time 1.00
Received By rmcdouga Date 2003-02-04 Time 14:26 Sent To  
Notes
2003-02-04 00:00:00PRODUCT APPROVAL FOR FRONT DOOR IS OK.
 CHANGE STORM PANEL MANUFACTURER. PRODUCT
 APPROVALS, KEY PLAN & INSTALLATION
 SCHEDULE IS OK.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2003-01-30 Cont ID  
Sent By rmcdouga Date 2003-01-30 Time 13:46 Rev Time 3.00
Received By rmcdouga Date   Time   Sent To  
Notes
2003-01-30 00:00:00BUILDING PROVISO
  
 1)PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - DOUBLE OUTSWING FRONT DOORS (THE ONES
 THAT WERE SUBMITTED WERE NOT THE FINAL
 NOAS)

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2003-01-14 Cont ID  
Sent By hmoser Date 2003-01-04 Time 08:17 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2003-01-14 00:00:00BUILDING DENIED
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) FL BLD CODE 1804.2.2 QUESTIONABLE
 SOILS, WHERE THE BEARING CAPACITY IS
 NOT DEFINETLY KNOWN OR IS IN QUESTION.
 PROVIDE A SOIL BEARING TEST REPORT FROM
 A LICENSED SOIL ENGINEER.
  
 3) CLARIFY THE DOOR SIZE FOR THE CABANA
 BATH. IS IT 2-10 OR 2-8 ?
  
 5) SECTION 5 ON S2 SPECIFIES A "USP"
 HUG 26 CONNECTOR. THIS APPEARS TO BE A
 HANGER TYPE CONNECTOR, HOWEVER, I COULD
 NOT LOCATE A HANGER WITH THIS MODEL
 NUMBER. IS THIS A "USP" HUS HANGER.
 PLEASE CLARIFY.
  
 6) PROVIDE A DETAIL OF THE WOOD FRAME
 EXTERIOR BEARING WALLS ON THE SECOND
 FLOOR. SPECIFY THE CONNECTORS THAT WILL
 BE USED TO TRANSFER THE LOADS FROM THE
 TRUSSES TO THE FLOOR GIRDERS.
  
 7) THE ENERGY CALCULATION FORM IS
 REQUIRED TO BE SIGNED AND DATED BY THE
 OWNER/AGENT.
  
 8) THE A/C AREA ON THE PLANS IS LISTED
 AS 3414 SQFT AND THE CONDITIONED SPACE
 ON THE ENERGY CALCS. IS 3101 SQFT.
 PLEASE CORRECT.
  
 9) PROVIDE A STRUCTURAL DETAIL OF THE
 BOLLARD IN THE GARAGE THAT IS PROTECTING
 THE WATER HEATER.
  
 10) THE INSTALLATION SCHEDULE AND KEY
 PLAN SUBMITTED ARE NOT FOR THIS MODEL.
 SUBMIT THE CORRECT ONES.
  
 11) PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - SLIDING GLASS DOORS
 - STRUCTURAL MULLIONS
 - OVAL FIXED GLASS WINDOWS
 - ARCHED FIXED GLASS WINDOWS
 - DOUBLE OUTSWING FRONT DOORS (THE ONE
 SUBMITTED IS A PRELIMINARY NOA, THE
 FINAL ONE WILL HAVE THE RENEWAL STAMP ON
 THE DRAWINGS AND THE LOGO ON THE COVER
 SHEET.
  
 12) THE DRYER VENT CAN NOT PENETRATE THE
 WALL AT THE ZERO LOT LINE. THE FBC TABLE
 600 DOES NOT ALLOW ANY OPENINGS WITHIN
 THREE FEET OF THE PROPERTY LINE.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop Z ZONING
Rev No 2 Status P Date 2002-12-23 Cont ID  
Sent By sgraham Date 2002-12-23 Time 12:50 Rev Time 0.25
Received By sgraham Date   Time   Sent To P
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2002-12-13 Cont ID  
Sent By dpalmer Date 2002-12-19 Time 09:40 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
2002-12-13 00:00:00DENIED NEED SITE PLAN