Plan Review Details - Permit 02120174
Plan Review Stops For Permit 02120174
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-12-30 Cont ID  
Sent By dpalmer Date 2002-12-30 Time 19:20 Rev Time 0.25
Received By dpalmer Date 2002-12-30 Time 19:20 Sent To B
Notes
2002-12-30 00:00:00SUB PANEL "B" NOT SHOWN ON FLOOR PLAN,
 REDLINED NOTE ON PLAN.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-05-29 Cont ID  
Sent By shernand Date 2003-05-29 Time 11:55 Rev Time 0.00
Received By shernand Date 2003-05-29 Time 11:55 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-01-29 Cont ID  
Sent By dpalmer Date 2003-01-29 Time 10:43 Rev Time 0.00
Received By dpalmer Date 2003-01-29 Time 10:43 Sent To M
Notes
2003-01-29 00:00:00TO MECH INBOX.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-12-04 Cont ID  
Sent By dpalmer Date 2002-12-04 Time 17:12 Rev Time 0.00
Received By dpalmer Date 2002-12-04 Time 17:12 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-06-05 Cont ID  
Sent By pkrauss Date 2003-06-05 Time 08:42 Rev Time 0.25
Received By pkrauss Date 2003-06-05 Time 08:42 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-02-08 Cont ID  
Sent By shernand Date 2003-05-29 Time 11:56 Rev Time 0.50
Received By hmoser Date 2003-02-08 Time 11:11 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-12-28 Cont ID  
Sent By dpalmer Date 2003-01-29 Time 10:43 Rev Time 0.25
Received By jleech Date 2002-12-28 Time 09:36 Sent To  
Notes
2002-12-28 00:00:00DENIED;
 A/C FLOOR PLAN DOES NOT MATCH FLOOR PLAN
 EE SHT A-1.
 A/C PLAN REVIEW BY;
 JOHN LEECH
 659-8096 EXT. 8369

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-12-16 Cont ID  
Sent By sgraham Date 2002-12-12 Time 10:00 Rev Time 0.25
Received By jleech Date 2002-12-16 Time 20:13 Sent To M
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2003-02-10 Cont ID  
Sent By jgomez Date 2003-02-10 Time 15:03 Rev Time 2.00
Received By jgomez Date 2003-02-10 Time 15:03 Sent To  
Notes
2003-02-10 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS UNDER A SEPARATE PERMIT.
 2-FLOOD ZONE A8; NEED TO PROVIDE THE
 ELEVATION CERTIFICATE.
 3-CLARIFY DETAIL FOR CONNECTION AT TOP
 OF COLUMN LOCATED BETWEEN GARAGE AND
 KITCHEN. SEE SECOND FLOOR FRAMING PLAN
 AND DETAIL PROVIDED. THEY DON'T MATCH.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC
 2001.
 4-DETAIL R19: SPECIFY ALL CONNECTORS.
 ROOF FRAMING PLAN DON'T SPECIFY THEM
 EITHER. SEC. 104.2.1.2 CITY AMENDMENTS
 TO FBC 2001.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2003-01-09 Cont ID  
Sent By jgomez Date 2003-01-09 Time 11:54 Rev Time 2.00
Received By jgomez Date 2003-01-09 Time 11:54 Sent To  
Notes
2003-01-09 00:00:00BUILDING REVIEW PROVISO:
 1-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS UNDER A SEPARATE PERMIT.
 2-FLOD ZONE A9: NEED TO PROVIDE THE
 ELEVATION CERTIFICATE.
 3-SHEET A-1: REVISE/CLARIFY NOTE #24.
 SEE SEC. 1007.5.1 FBC 2001 FOR HEIGHT
 OF HANDRAILS.**NOTE: HANDRAILS AND
 GUARDRAILS ARE NOT THE SAME.
 4-GLASS BLOCK TO BE SAFETY GLASS IF FACE
 THICKNESS IS LESS THAN 0.25". SECTION
 2405.2.2 FBC 2001.
 5-SHEET A-4: REVISE/CLARIFY NOTE #1. SEE
 SEC. 1007.5.1 FBC 2001 FOR HEIGHT OF
 HANDRAILS. **NOTE: HANDRAILS AND
 GUARDRAILS ARE NOT THE SAME.
 6-PROVIDE GENERAL SPECS FOR FIREBLOCKING
 AT ALL CONCEALED SPACES AS REQUIRED BY
 SEC. 2305.1.4 FBC 2001.
 7-PROVIDE COMPLETE DETAIL/SECTION FOR
 CONNECTION AT TOP OF COLUMN LOCATED
 BETWEEN GARAGE AND KITCHEN. CLARIFY
 HOW IS SPECIFIED STRAP HOLDING THE
 TWO GIRDER TRUSSES. SECTION 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
 8-SHEET S-3: PROVIDE SPECS ON STRUCTURAL
 WALL SECTIONS FOR FIRECUT REQUIREMENTS
 SEC. 2305.4 FBC 2001.
 9-DETAIL R19: CLEARLY SPECIFY ALL CONNEC
 TORS. ROOF FRAMING PLAN DOESN'T SHOW
 THEM.SEC. 104.2.1.2 CITY AMENDMENTS.
 10-SPECIFY SIZE OF ANCHOR BOLT & WASHER
 FOR GARAGE DOOR STRUCTURAL BUCK DETAIL
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.

Review Stop Z ZONING
Rev No 1 Status P Date 2002-12-12 Cont ID  
Sent By dpalmer Date 2002-12-04 Time 17:12 Rev Time 0.25
Received By sgraham Date   Time   Sent To P
Notes
***NONE***