Plan Review Stops For Permit 02120132 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2003-08-11 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2003-08-11 |
Time |
08:59 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2003-08-11 |
Time |
08:58 |
Sent To |
|
|
Notes |
2003-08-11 00:00:00 | REVISION SUBMITTED 7/28/03 INCREASING | | SCOPE TO INCLUDE SECOND FLOOR BUILD-OUT. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2003-07-10 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2003-07-10 |
Time |
18:18 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2003-07-10 |
Time |
18:18 |
Sent To |
|
|
Notes |
2003-07-10 00:00:00 | BUILDING PLAN REVIEW | | *******DENIED******* | | ROBERT BROWN(561) 805 6716 | | E-MAIL: [email protected] | | | | REVISION SUBMITTED 6/17/03. | | | | FBC = FLORIDA BUILDING CODE 2001 | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | 1) FBC* 104.1.5THE PROPOSED REVISIONS | | INCREASE THE SCOPE OF THE WORK.THE | | VALUE OF THE ADDITIONAL WORK SHALL BE | | DECLARED AND JUSTIFIED (E.G. WITH COPIES | | OF CONTRACTS) SO THAT THE ADDITIONAL | | PERMIT FEES DUE MAY BE DETERMINED. | | | | 2) FBC 11-4.24BREAK ROOM #3.REVISED | | SHEET A9 DOES NOT SHOW ANY DETAILS TO | | DEMONSTRATE THE ACCESSIBILITY OF THE | | SINK IN BREAK ROOM #3.AMEND THE PLANS. | | | | 3) FBC 2405.2THE FOLLOWING GLAZING IS | | IN A 'HAZARDOUS LOCATION' AND IS | | REQUIRED TO BE SAFETY GLASS SATISFYING | | THE REQUIREMENTS OF THE CONSUMER PRODUCT | | SAFETY COMMISSION 16, CODE OF FEDERAL | | REGULATIONS, PART 1201 (CPSC 16-CFR, | | PART 1201): | | - THE GLAZING IN REVISED DOORS 2A & 2B | | - THE GLAZING IN THE TWO NEW DOORS #25 | | - THE GLAZED SIDELITE PANELS ADJACENT | | EACH OF THE TWO NEW DOORS #25 | | AMEND/ANNOTATE THE DOOR AND WINDOW | | SCHEDULES TO DEMONSTRATE COMPLIANCE. | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | END OF REVIEW COMMENTS | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | TELEPHONE: (561) 805 6716ROBERT BROWN | | E-MAIL: [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2003-03-25 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2003-03-25 |
Time |
11:20 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2003-03-25 |
Time |
11:20 |
Sent To |
|
|
Notes |
2003-03-25 00:00:00 | BUILDING PLAN REVIEW | | ******PROVISO******* | | ROBERT BROWN(561) 659 8096 EXT 8499 | | | | --PROVISO-- | | THE SUBMITTED STORE FRONT DOOR PRODUCT | | APPROVAL NOA# 01-0919.02 IS FOR SINGLE | | UNIT APPLICATIONS ONLY, AND SO DOES NOT | | COVER THE MULLED SIDELITES ADJACENT | | DOOR #1.STRUCTURAL MULLIONS ARE | | REQUIRED. ALSO, THE SIDELITES EXCEED THE | | 96" MAX. HEIGHT COVERED BY THE WINDOW | | WALL SYSTEM PRODUCT APPROVAL | | NOA# 01-0329.02, SO A HORIZONTAL MULLION | | IS REQUIRED.SUBMIT AN APPROPRIATE | | STRUCTURAL MULLION PRODUCT APPROVAL OR | | SITE SPECIFIC ENGINEERING. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2003-03-19 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-03-22 |
Time |
15:42 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2003-03-19 |
Time |
14:46 |
Sent To |
|
|
Notes |
2003-03-19 00:00:00 | BUILDING PLAN REVIEW | | *******DENIED******* | | ROBERT BROWN(561) 659 8096 EXT 8499 | | | | FBC = FLORIDA BUILDING CODE 2001 | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS | | ARE NUMBERED AS PER THE BUILDING PLAN | | REVIEW OF 1/16/03: | | | | 2) JMS DESIGN RESPONSE DATED 2/25/03 IS | | NOTED.IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | COPY OF RECEIPT SUBMITTED TO CITY OF | | WEST PALM BEACH BUILDING DEPARTMENT, | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | 5) THE SUBMITTED STORE FRONT DOOR | | PRODUCT APPROVAL NOA# 01-0919.02 IS FOR | | SINGLE UNIT APPLICATIONS ONLY, AND SO | | DOES NOT COVER THE MULLED SIDELITES | | ADJACENT DOOR #1.SUBMIT AN APPROPRIATE | | STRUCTURAL MULLION PRODUCT APPROVAL OR | | SITE SPECIFIC ENGINEERING. | | | | 17) FBC* 104.2.2SHEETS S.1, S.2, S.6 | | AND S.8.POST SEAL AMENDMENTS TO THE | | STRUCTURAL PLANS SHALL BE SIGNED AND | | DATED BY THE ENGINEER OF RECORD. | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | END OF REVIEW COMMENTS | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | IF YOU HAVE ANY QUESTIONS PLEASE CALL: | | ROBERT BROWN(561) 659 8096 EXT 8499 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-01-16 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2002-12-17 |
Time |
10:14 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2003-01-16 |
Time |
16:41 |
Sent To |
|
|
Notes |
2003-01-16 00:00:00 | BUILDING PLAN REVIEW | | *******DENIED******* | | ROBERT BROWN(561) 659 8096 EXT 8499 | | | | FBC = FLORIDA BUILDING CODE 2001 | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | 1) A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | PERMIT CAN BE ISSUED. | | | | 2) IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | COPY OF RECEIPT SUBMITTED TO CITY OF | | WEST PALM BEACH BUILDING DEPARTMENT, | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | 3) FBC* 1804.2.2SUBMIT A GEOTECHNICAL | | REPORT. | | | | 4) FBC* 104.1.1A SEPARATE PERMIT | | APPLICATION WILL BE REQUIRED FOR THE | | DUMPSTER ENCLOSURE. | | | | 5) SUBMIT PRODUCT APPROVALS FOR THE | | EXTERIOR DOORS, WINDOWS AND ROOFING. | | | | 6) FBC 13-103.1.2BEFORE A BUILDING | | PERMIT CAN BE ISSUED, THE SUBMITTED | | ENERGY CODE COMPLIANCE FORMS SHALL BE | | SIGNED BY THE BUILDING OWNER, THE | | OWNER'S ARCHITECT OR OTHER AUTHORIZED | | AGENT LEGALLY DESIGNATED BY THE OWNER. | | ***NOTE: ADD THE FULL STREET ADDRESS, | | 2130 CENTREPARK DRIVE W, TO THE PROJECT | | INFORMATION SECTION OF EACH COPY OF THE | | COMPLIANCE FORM BEFORE RESUBMITTING. | | | | 7) FBC 1004.1.4ARRANGEMENT OF EXITS. | | THE STRAIGHT LINE DISTANCE BETWEEN THE | | SECOND FLOOR EXIT DOORS SHALL NOT BE | | LESS THAN 1/2 THE LENGTH OF THE MAXIMUM | | DIAGONAL DIMENSION OF THE BUILDING, | | WHICH IS APPROX. 155 FT.AMEND THE | | PLANS TO ACHIEVE COMPLIANCE. | | | | 8) FBC 11-4.1.3(9)AREAS OF RESCUE | | ASSISTANCE ARE REQUIRED BECAUSE THE | | BUILDING IS NOT SPRINKLERED.AMEND THE | | PLANS TO IDENTIFY LOCATIONS.ONE OPTION | | IS TO PROVIDE DETAILS TO SHOW THAT THE | | STAIR #2 LANDING AND THE ELEVATOR | | LOBBY #2, ADJACENT STAIR #1, COMPLY WITH | | THE REQUIREMENTS OF FBC 11-4.3.11.1. | | NOTE: IF STAIR #1 IS REVERSED, THEN THAT | | LANDING COULD BE USED INSTEAD OF HAVING | | TO UPGRADE THE ELEVATOR LOBBY TO MEET | | THE REQUIREMENTS FOR AN AREA OF RESCUE | | ASSISTANCE. | | | | 9) FBC 4.3.11.3STAIRWAY WIDTH. AS PART | | OF THE REQUIREMENTS FOR AREAS OF RESCUE | | ASSISTANCE IN A NON-SPRINKLERED | | BUILDING, THE STAIRWAYS SHALL HAVE A | | CLEAR WIDTH OF 48" BETWEEN HANDRAILS. | | | | 10) FBC 4.3.11.4TWO-WAY COMMUNICATION | | IS REQUIRED BETWEEN THE AREAS OF RESCUE | | ASSISTANCE AND THE PRIMARY ENTRANCE. | | | | 11) FBC 705.1.2EXIT DOORS.THE DOORS | | TO THE STAIR #1 AND #2 ENCLOSURES AND TO | | THE FIRST FLOOR LOBBY (SHEET A.6DOOR | | SCHEDULE MARKS 2, 4 AND 19) ARE REQUIRED | | TO PROVIDE 1 HOUR FIRE RESISTANCE. | | AMEND THE DOOR SCHEDULE TO SHOW THIS | | REQUIREMENT. | | | | 12) FBC 11-4.13.6 MANEUVERING CLEARANCES | | AT DOORS.THE LEADING EDGE OF THE DOORS | | TO 'OFFICE 4' (DOOR 9) AND 'BREAK 1' | | (DOOR 7) AND 'CUSTOMER AREA' (DOOR 7) ON | | THE FIRST FLOOR SHALL NOT BE LESS THAN | | 18" FROM THE ADJACENT WALL ON THE PULL | | SIDE OF THE DOOR. | | | | 13) FBC 11.4.9.4(2)SHEET A.4, TYPICAL | | STAIR DETAILS.THE STAIR HANDRAIL SHALL | | EXTEND AT LEAST 12" HORIZONTALLY BEYOND | | THE TOP RISER, AND SHALL CONTINUE TO | | SLOPE PAST THE BOTTOM RISER , FOR A | | DISTANCE EQUAL TO THE WIDTH OF ONE | | TREAD, AND THEN EXTEND A FURTHER 12" | | HORIZONTALLY AT THE BOTTOM. | | | | 14) FBC 11-4.15DRINKING FOUNTAINS. | | THE ELEVATIONS ON SHEET A.7 DO NOT SHOW | | THE HEIGHT AND THE LEG CLEARANCES FOR | | DRINKING FOUNTAINS.AMEND/SUBMIT PLANS, | | FOR THE FIRST AND SECOND FLOOR DRINKING | | FOUNTAINS, TO DEMONSTRATE COMPLIANCE | | WITH THE REQUIREMENTS OF FIG. 27. | | | | 15) FBC 11-4.16.3 & 4W.C. HEIGHT AND | | GRAB BARS.THE ELEVATIONS ON SHEET A.7 | | DO NOT SHOW THE W.C. HEIGHT AND GRAB BAR | | PLACEMENT.AMEND/SUBMIT PLANS TO | | DEMONSTRATE COMPLIANCE WITH THE FIG. 29 | | REQUIREMENTS FOR ACCESSIBLE W.C'S. | | | | 16) SHEET A.5, FIRST FLOOR WINDOWS.THE | | NORTH END OF THE WEST ELEVATION SHOWS | | TWO FIRST FLOOR WINDOWS WHICH ARE NOT | | SHOWN ON THE FIRST FLOOR PLAN. | | | | 17) SHEET S.6, SECTION 3, WOOD GABLE END | | TRUSS ANCHORING.FROM SIMPSON PRODUCT | | LITERATURE IT APPEARS THAT THE PROPOSED | | HUC26 ANCHORS MAY NOT HAVE SUFFICIENT | | CAPACITY FOR A 24 FT SPAN TRUSS WITH | | THIS TRIBUTARY WIDTH (APPROX. 1'-4" PLUS | | THE DEPTH OF THE PROFILE 3 PARAPET CAP). | | ADD THE CALCULATED UPLIFT TO THE PLANS | | FOR CROSS REFERENCE AGAINST THE PROPOSED | | ANCHOR. | | | | 18) IF NEW PLAN SHEETS ARE REQUIRED, IN | | ORDER TO ADDRESS THE ABOVE COMMENTS, THE | | OLD SHEETS SHALL BE REMOVED AND THE NEW | | SHEETS INSERTED.ONE COPY OF EACH OLD | | SHEET SHALL BE INCLUDED WITH THE | | RESUBMITTAL FOR COMPARISON OF REVISIONS. | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | END OF REVIEW COMMENTS | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | IF YOU HAVE ANY QUESTIONS PLEASE CALL: | | ROBERT BROWN(561) 659 8096 EXT 8499 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2003-08-26 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-11-03 |
Time |
10:57 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2003-08-26 |
Time |
19:05 |
Sent To |
|
|
Notes |
2003-08-26 00:00:00 | REV FOR BLD OUT OK. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2003-08-05 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-08-05 |
Time |
15:01 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2003-08-05 |
Time |
15:01 |
Sent To |
|
|
Notes |
2003-08-05 00:00:00 | ************* UNSAT ***************** | | | | 1)NOTE: PLEASE SEE NOTES FROM LAST | | REVIEW. PLEASE SEE THAT REVISED LOAD | | CALCULATIONS AND PANEL SCHEDULES HAVE | | NOT BEEN SUBMITTEDTO CORRELATE WITH | | NEW SCOPE OF WORK ADDED. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2003-07-07 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-07-28 |
Time |
15:05 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2003-07-07 |
Time |
07:04 |
Sent To |
|
|
Notes |
2003-07-07 00:00:00 | *** NOTE **** | | | | SEE BLDG PLAN REVIEW NOTES, BLD OUT OF | | 2ND FLOOR NOT ON ORIG VALUE/SCOPE. | | | | PLANS NEED TO BE REVISED TO INCLUDE ANY | | PANEL SCHEDULES TO CORRELATE WITH | | ELECTRICAL FLOOR PLAN SUBMITTED. | | | | PLEASE SUBMIT THE ABOVE FOR REVIEW | | BEFORE FINAL. IF THERE ARE ANY QUESTIONS | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2003-03-13 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-03-13 |
Time |
17:44 |
Rev Time |
1.00 |
Received By |
dpalmer |
Date |
2003-03-13 |
Time |
17:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2002-12-26 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-12-26 |
Time |
07:03 |
Rev Time |
2.00 |
Received By |
dpalmer |
Date |
2002-12-26 |
Time |
07:03 |
Sent To |
|
|
Notes |
2002-12-26 00:00:00 | **************** UNSAT ************** | | | | 1)NOTE:PLEASE SEE E2.1, SOME CIRCUITS | | MISSING CIRCUIT | | DESIGNATION. | | | | 2)NOTE: PLEASE SEE FIRE REVIEW COMMENTS | | THAT WILL AHVE AN AFFECT ON ELECTRICAL | | SHEETS. | | | | 3)NOTE: PLEASE NOTE/CLARIFY LTS FIXTURES | | IN ELEV /ELEC ROOMS TO MEET 700-16 | | | | | | | | | | | | | | | | | | | | | | | | 6)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | ALL NEW EQUIPENT. 110-9/215-5 | | | | 7)NOTE: PLEASE SHOW SIZE OF METERCAN | | "H1A".? | | | | 8)NOTE: PLEASE NOTE ALL CONTINUOUS LOADS | | ARE TO BE SHOWN AT 125%. 215-3/230-42 ET | | C. | | | | 9)NOTE: PLEASE SEE WATER HEATER ON H2A | | 2P-30A W/ #12`S, PLEASE SIZE WIRE PER | | 310-16 | | | | 10)NOTE: PLEASE NOTE "L2B" IS REQ`D TO | | HAVE A MCB ON LOAD SIDE OF TRANSFORMER | | 384-16,240-21 | | | | 11)NOTE: PLEASE SHOW MIN LOAD FOR | | FUTURE TENANT SPACE AND HOW LOAD WAS | | FIGURED. | | | | 12)NOTE: PLEASE CLARIFY WHERE LPA PANEL | | SCHEDULE IS SHOWN? | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
3 |
Status |
P |
Date |
2003-04-01 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2003-04-01 |
Time |
12:31 |
Rev Time |
1.00 |
Received By |
mmclean |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2003-04-01 00:00:00 | PROVISO : | | | | BUILDING PERMIT ISSSUED BY L. MARTINEZ | | UNDER THE AGREEMENT WITH RON NETTLES | | THAT UNDERGROUND PERMIT WILL BE ISSUED | | BEFORE VERTICLE CONSTRUCTION | | | | | | L. MARTINEZ |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
F |
Date |
2003-03-03 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2003-03-03 |
Time |
13:26 |
Rev Time |
1.00 |
Received By |
mamini |
Date |
2003-03-03 |
Time |
13:26 |
Sent To |
|
|
Notes |
2003-03-03 00:00:00 | FAILED: | | 1. PLEASE NOTE THAT A SEPARATE PERMIT | | APPLICATION AND FEES FOR UNDERGROUND | | UTILITIES AND CIVIL SITE WORK IS | | REQUIRED, PLEASE SUBMIT TWO SETS OF | | CIVIL PLANS ONLY. | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2003-01-16 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2003-01-16 |
Time |
08:41 |
Rev Time |
3.00 |
Received By |
mamini |
Date |
2003-01-16 |
Time |
08:41 |
Sent To |
|
|
Notes |
2003-01-16 00:00:00 | FAILED: | | 1. PLEASE NOTE THAT A SEPARATE PERMIT | | APPLICATION AND FEES FOR UNDERGROUND | | UTILITIES AND CIVIL SITE WORKS WILL BE | | REQUIRED. | | 2. ALL BACKFLOW PREVENTERS MUST BE | | COMPLETELY HIDDEN FROM VIEW WITH SHRUBS | | PRIOR TO ACTIVATION. | | 3. DRIVEWAYS APPROACHES MUST BE | | CONSTRUCTED AT MIN. PER THE CITY OF WPB | | STANDARD AND REQUIREMENT. | | 4. POLLUTION/ EROSION PLANS MUST BE | | INSTALLED IN FIELD PRIOR TO ANY EARTH | | WORK/ CONSTRUCTION. | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
P |
Date |
2003-09-02 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2003-09-02 |
Time |
16:27 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2003-09-02 |
Time |
16:27 |
Sent To |
|
|
Notes |
2003-09-02 00:00:00 | APPROVED PROVISO | | | | ARE THE DOORS AT LOBBY 2B, 25 AND THE | | DOOR 18 AT THE EXECUTIVE SECRETARY AREA | | SWINGING IN THE RIGHT DIRECTION. | | REMEMBER IF 50 OR MORE PERSONS ARE | | EXPECTED TO USE THESE DOORS FOR EXIT | | ACCESS, THEN THEY SHOULD SWING IN THE | | DIRECTION OF EXIT TRAVEL. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 835-2910 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2003-07-15 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-21 |
Time |
12:43 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2003-07-15 |
Time |
10:02 |
Sent To |
|
|
Notes |
2003-07-15 00:00:00 | **************PROVISO******************* | | SEPARATE SHOP DRAWINGS AND PERMITS | | APPLICATIONS ARE REQUIRED FOR FIRE ALARM | | AND FIRE SPRINKLER SYSTEMS REVISION OR | | REMODEL. | | | | NATE MCCRAY, CAPTAIN | | 805-6722 OR 835-2910 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2003-03-07 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2003-03-07 |
Time |
09:26 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2003-03-07 |
Time |
09:26 |
Sent To |
|
|
Notes |
2003-03-07 00:00:00 | COULD NOT LOCATE NOTE 24 ON FAO.1. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2002-12-19 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2002-12-19 |
Time |
09:11 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2002-12-19 |
Time |
09:11 |
Sent To |
|
|
Notes |
2002-12-19 00:00:00 | 1) THE PROPOSED FIRE HYDRANT IS TO MEET | | UTILITY AND FIRE RESCUE STANDARDS. | | TYPICALLY, THE CITY DOES NOT USE THE | | COLOR RED FOR FIRE HYDRANTS. | | | | 2) ELECTRONIC SWITCHES WILL BE REQUIRED | | ON BACKFLOW DEVICES THAT CONTROL FIRE | | LINE SERVICE. | | | | 3) PLEASE INDICATE INTERIOR FINISH | | CLASSIFICATION INFORMATION FOR WALLS | | AND CEILINGS. | | | | 4) PLEASE PROVIDE A LIFE SAFETY PLAN | | INDICATING OCCUPANT LOADS AND TRAVEL | | DISTANCES. ALSO PLEASE DEMONSTRATE | | COMPLIANCE WITH EXIT SEPARATION | | REQUIREMENTS OF AT LEAST 1/2 THE | | DIAGONAL DISTANCE SINCE NO FIRE | | SPRINKLER SYSTEM IS PLANNED. | | | | 5) A REMOTE FIRE ALARM ANNUNCIATOR | | APPEARS TO BE REQUIRED AT THE FRONT | | ENTRYWAY. | | | | 6) SINCE NO FIRE SPRINKLERS ARE PLANNED, | | ALL ELECTRICAL,MECHANICAL, AND STORAGE | | ROOMS ARE TO BE AT LEAST ONE HOUR | | FIRE RATED WITH RATED OPENING | | PROTECTIVE DEVICES. | | | | 7) AN EXIT SIGN IS MISSING INFRONT OF | | STAIR # 2, FIRST FLOOR. | | | | 8) A KNOX-BOX WILL BE REQUIRED FOR | | THE BUILDING. | | | | 9) NO BUILDING ELEVATION DRAWINGS | | PROVIDED. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2003-11-03 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-11-03 |
Time |
10:56 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-11-03 |
Time |
10:56 |
Sent To |
E |
|
Notes |
2003-11-03 00:00:00 | TO DP DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2003-08-21 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-21 |
Time |
12:43 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-08-21 |
Time |
12:42 |
Sent To |
FIRE |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2003-08-14 |
|
|
Cont ID |
|
Sent By |
dbaxter |
Date |
2003-08-14 |
Time |
16:43 |
Rev Time |
0.00 |
Received By |
dbaxter |
Date |
2003-08-14 |
Time |
16:43 |
Sent To |
|
|
Notes |
2003-08-14 00:00:00 | TO COMM BD. #20 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2003-08-05 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-07-28 |
Time |
15:05 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-07-28 |
Time |
15:05 |
Sent To |
|
|
Notes |
2003-07-28 00:00:00 | TO COMM BD #14 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-06-17 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-06-17 |
Time |
16:30 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-06-17 |
Time |
16:30 |
Sent To |
|
|
Notes |
2003-06-17 00:00:00 | COMM BOARD #49 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2002-12-18 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-12-18 |
Time |
09:32 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2002-12-17 |
Time |
09:32 |
Sent To |
|
|
Notes |
2002-12-18 00:00:00 | TO COM BOARD #37./WRT. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2002-12-03 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-12-03 |
Time |
16:55 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2002-12-03 |
Time |
16:55 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2003-08-29 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-08-29 |
Time |
10:49 |
Rev Time |
0.30 |
Received By |
pkrauss |
Date |
2003-08-29 |
Time |
10:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2003-07-08 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-07-08 |
Time |
07:19 |
Rev Time |
0.40 |
Received By |
pkrauss |
Date |
2003-07-08 |
Time |
07:09 |
Sent To |
|
|
Notes |
2003-07-08 00:00:00 | PROVISO: | | | | PLAN SHEET M2.2, THE WALL BETWEEN THE | | BREAK ROOM AND STORAGE ROOM HAS A 1 HR | | RATING, AS PER 2001 FBC(M) 607.1.3 | | EXCEPTIONS - FIRE DAMPERS ARE NOT | | REQUIRED UNDER THE FOLLOWING CONDITIONS: | | #3 ITEMS 1 THROUGH 4 AS FOLLOWS | | 1. DUCTS DO NOT EXCEED 100 SQ INCHES | | 2. DUCT SHALL BE A MINIMUM OF .0217 INCH | | STEEL | | 3. DUCT SHALL CONTINUE WITH NO DUCT | | OPENINGS FOR NOT LESS THAN 5 FT FROM | | THE RATED WALL | | 4. THE DUCT SHALL BE ISNTALLED ABOVE THE | | CEILING | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2003-03-14 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-03-14 |
Time |
08:01 |
Rev Time |
0.55 |
Received By |
pkrauss |
Date |
2003-03-10 |
Time |
13:53 |
Sent To |
|
|
Notes |
2003-03-14 00:00:00 | MECHANICAL PERMIT 02120134 - PROVISO | | ON PLAN |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2002-12-28 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2002-12-27 |
Time |
13:37 |
Rev Time |
1.45 |
Received By |
hmoser |
Date |
2002-12-27 |
Time |
11:59 |
Sent To |
|
|
Notes |
2002-12-28 00:00:00 | 3.NO DUCT SIZE OR SCHEDULE FOR | | FLEX DUCT | 2002-12-27 00:00:00 | DENIED: | | | | 1.PROVIDE DETAIL FOR FIRE DAMPER IN A | | HORIZONTAL APPLICATION. | | | | 2.PLEASE CLARIFY NOTE 1 ON PLAN SHEET | | M2-3, "SHAFT RISER" REF. M6.1, ARE DUCTS | | IN A 1 HR SHAFT? |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2003-09-03 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-09-03 |
Time |
16:31 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2003-09-03 |
Time |
16:31 |
Sent To |
|
|
Notes |
2003-09-03 00:00:00 | REVISION OK - SANT. RISER DIAGRAM/WATER | | RISER DIAGRAM. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2003-07-02 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-07-02 |
Time |
16:11 |
Rev Time |
1.50 |
Received By |
kstevens |
Date |
2003-07-02 |
Time |
14:36 |
Sent To |
|
|
Notes |
2003-07-02 00:00:00 | REVISION OK - FUTURE TENANT BUILD-OUT ON | | SECOND FLOOR - SANT. AND WATER RISER | | DIAGRAMS SHALL BE REVISED TO REFLECT | | CHANGES ON SHTS P2.2 & P3.2 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2003-03-22 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-03-22 |
Time |
15:42 |
Rev Time |
0.20 |
Received By |
kstevens |
Date |
2003-03-22 |
Time |
15:41 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2003-03-20 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-03-20 |
Time |
11:47 |
Rev Time |
1.00 |
Received By |
kstevens |
Date |
2003-03-20 |
Time |
11:47 |
Sent To |
|
|
Notes |
2003-03-20 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 11 | | | | 1) FROM PREVIOUS REVIEW, SHT PO.1 THERM- | | AL EXPANSION CONTROL REQUIRED PER SEC. | | 607.3.2. PLEASE SHOW ON W/H'S #1 & #2. | | SHEETS WERE NOT CHANGED. | | 2) FROM PREVIOUS REVIEW, SHT P6.1 WATER | | RISER DIAGRAM, WATER HAMMER ARRESTORS | | REQUIRED BY SEC 604.9 SHALL BE LOCATED | | NEAR THE FIXTURES IN AN "EFFECTIVE RANGE | | NOT AT THE TOP OF DROPS IN THE CEILING | | AS SHOWN. PDI-WH 201 AND MANUF. INSTALL- | | ATION INSTRUCTIONS. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2002-12-31 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-12-30 |
Time |
16:11 |
Rev Time |
1.50 |
Received By |
kstevens |
Date |
2002-12-30 |
Time |
16:10 |
Sent To |
|
|
Notes |
2002-12-30 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 11 | | | | 1) STH A.7 PRIVATE TOILET ROOM FOR EXEC. | | SHALL BE ADAPTABLE PER 11-4.1.3(11). | | SHOW DETAIL FOR GRAB BAR BACKING, OPEN- | | ING FOR W/C, LAV HEIGHT (34") ECT. | | 2) SHT A.9 BREAK ROOM ELEVATIONS #'S 1 & | | 2. SINKS SHALL COMPLY WITH 11-4.24 AND | | ALL SUBSECTIONS. PLEASE SHOW DETAILS. | | 3) SHT P0.1 THERMAL EXPANSION CONTROL | | REQUIRED PER SEC 607.3.2. PLEASE SHOW | | ON WATER HEATER DETAIL EWH #1 & EWH #2. | | 4) SHT P2.1 - RELIEF VENT REQUIRED ON | | CONDENSATE LINE AS IT EXITS BLDG. | | 5) SHT P6.1 WATER RISER DIAGRAM, WATER | | HAMMER ARRESTORS REQUIRED BY 604.9 SHALL | | BE LOCATED NEAR THE FIXTURES IN AN | | "EFFICTIVE RANGE" NOT AT TOP OF DROPS IN | | CEILING AS SHOWN. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2002-12-17 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-12-03 |
Time |
16:56 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
B |
|
Notes |
|
|