Plan Review Stops For Permit 02120009 |
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2003-09-09 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-09-09 |
Time |
11:59 |
Rev Time |
1.00 |
Received By |
dpalmer |
Date |
2003-09-09 |
Time |
11:59 |
Sent To |
|
|
Notes |
2003-09-09 00:00:00 | OCP FOR A/C COND UNITS TO BE VERIFIED | | IN FIELD ALONG WITH MIN CIRCUIT AMPACITY | | ELEC CONT SUBMITTED INFORMATION OVER THE | | PHONE THAT MIN A'SON UNITS ARE 20 AND 25 | | A'S. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2003-08-22 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-08-22 |
Time |
11:17 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2003-08-22 |
Time |
11:17 |
Sent To |
|
|
Notes |
2003-08-22 00:00:00 | ************PROVISO/NOTE ********** | | | | 1)NOTE: PLEASE CORRELATE RISER DIAGRAM | | AND ALL PANELS. A/C SUB PANEL NOT SHOWN | | ON RISER. | | | | 2)NOTE: PLEASE SHOW CONDUITS FROM METER | | TO PANELS AS INSTALLED IN SLAB. | | 210.70 | | | | 3)NOTE: PLEASE VERIFY KW RATINGS FOR | | AHU'S, SHOWS 5KW UNIT ON 2P60A? IF 10KW | | UNIT, REVISE LOAD CALCUALTIONS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW BEFORE FINAL ELEC/CO. PARTIAL | | FINAL ELECTRICAL IS OK. | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2003-06-16 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-06-16 |
Time |
15:30 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2003-06-16 |
Time |
15:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2003-01-23 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-06-13 |
Time |
16:05 |
Rev Time |
0.55 |
Received By |
btrobaug |
Date |
|
Time |
|
Sent To |
M |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2003-01-03 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-01-03 |
Time |
12:06 |
Rev Time |
0.75 |
Received By |
btrobaug |
Date |
2003-01-03 |
Time |
11:29 |
Sent To |
P |
|
Notes |
2003-01-03 00:00:00 | UNSAT | | ~~~~~ | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | PLEASE NOTE THE FOLLOWING DISCREPANCIES | | MAKE ANY NECESSARY CORRECTIONS ON THE | | PLANS AND RESUBMIT FOR REVIEW. | | | | 1} THE DISCONNECT ON THE RISER DIAGRAM | | IS 300 AMPS,BEING FED WITH #2/0(200AMP) | | CONDUCTORS. THE LOAD CALCULATION IS IN | | EXCESS OF 200 AMPS. PLEASE CORRELATE | | OCP,CONDUCTORS,LOAD CALCULATION AND | | EQUIPMENT GROUND TO REFLECT WHAT IS TO | | BE INSTALLED. | | | | 2} THE CABANA BATH NEEDS A RECEPTACLE TO | | COMPLY WITH 210-11(C)(3),MUST BE GFI. | | | | 3} MASTER & BATH #2 NEEDS A RECEPTACLE | | ADDED TO COMPLY WITH 210-52(D). | | | | 4} BEDROOM #5 NEEDS TO HAVE SMOKE | | DETECTORS TO COMPLY 8-1.4.1.6.2(1) & | | (2). | | | | 5} AHU & WATER HEATER DISCONNECTS IN THE | | GARAGE MUST COMPLY WITH 110-26. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/659-8096 EXT. 8392 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-06-13 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-06-13 |
Time |
16:03 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-06-13 |
Time |
16:03 |
Sent To |
E |
|
Notes |
2003-06-13 00:00:00 | BT DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2002-12-02 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-12-02 |
Time |
17:03 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2002-12-02 |
Time |
17:03 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2003-01-30 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-01-30 |
Time |
10:20 |
Rev Time |
0.40 |
Received By |
pkrauss |
Date |
2003-01-30 |
Time |
10:20 |
Sent To |
|
|
Notes |
2003-01-30 00:00:00 | MECHANICAL 02120027 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2003-01-11 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-01-23 |
Time |
09:34 |
Rev Time |
0.50 |
Received By |
hmoser |
Date |
2003-01-11 |
Time |
06:45 |
Sent To |
R |
|
Notes |
2003-01-11 00:00:00 | PLAN DENIED | | ENERGY CALCULATIONS AND MANUAL (J) DO | | NOT MATCH | | PLAN REVIEW BY HAROLD MOSER | | (561)659-8096 EXT.8221 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2003-08-12 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-08-12 |
Time |
14:30 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2003-08-12 |
Time |
14:30 |
Sent To |
|
|
Notes |
2003-08-12 00:00:00 | REVISION OK - SANT. RISER DIAGRAM |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2003-01-11 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-01-03 |
Time |
12:06 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2003-01-11 |
Time |
06:29 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2003-01-30 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2003-01-11 |
Time |
06:45 |
Rev Time |
0.10 |
Received By |
pkrauss |
Date |
2003-01-30 |
Time |
10:26 |
Sent To |
|
|
Notes |
2003-01-30 00:00:00 | LOU HATTEN SIGNED OFF ON PLAN/DID NOT | | SIGN OFF IN COMPUTER.PLANS OKAY | | PER LOU HATTEN |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-01-02 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-12-02 |
Time |
17:03 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
P |
|
Notes |
|
|