Plan Review Details - Permit 02111891
Plan Review Stops For Permit 02111891
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-01-22 Cont ID  
Sent By jgomez Date 2003-01-22 Time 12:21 Rev Time 2.00
Received By jgomez Date 2003-01-22 Time 12:21 Sent To  
Notes
2003-01-22 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-STORM SHUTTERS PRODUCT APPROVAL WAS
 DELETED FROM SBCCI LIST. PROVIDE NEW
 UPDATED PRODUCT APPROVAL AND CLEARLY
 MARK ON DRAWINGS SPECIFIC MOUNTING
 CONDITIONS AND ANCHOR TYPE AND SPACING
 TO BE USED ACCORDING TO THE MEAN ROOF
 HEIGHT, DESIGN PRESSURES, PANEL SPAN,
 EDGE DISTANCE, CONNECTION TYPE AND
 STRUCTURE TO BE ATTACHED TO. ALSO,
 PROVIDE KEY PLAN AND INSTALLATION
 SCHEDULE. SEE ATTACHED CITY SAMPLE.
 2-PROVIDE FIREBLOCKING AT ALL CONCEALED
 SPACES. SEC. 2305.1.4 FBC 2001.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-01-08 Cont ID  
Sent By kstevens Date 2003-01-18 Time 07:21 Rev Time 2.50
Received By jgomez Date 2003-01-08 Time 12:02 Sent To  
Notes
2003-01-08 00:00:00BUILDING CHECKLIST:
 1-MISSING ONE SET OF STRUCTURAL DRAWINGS
 2-SPECIFY TABULATED AREAS. A/C AREAS,
 PORCHES, GARAGES.ETC. TO PROPERLY
 ASSESS VALUATION AND RADON FEES.
 3-PROVIDE ENERGY CALCULATIONS AS REQ'D
 ON CHAPTER 13 FBC 2001.
 4-PROVIDE SPECIFICATIONS FOR SHORING AND
 BRACING OF EXISTING STRUCTURE WHEN
 REMOVING BEARING WALLS.SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 5-CLEARLY SPECIFY ON PLANS SIZE AND TYPE
 OF BEDROOM EGRESS WINDOWS. SECTION
 1005.4.4 FBC 2001.
 6-REVISE STRUCTURAL BUCK DETAIL FOR EXT.
 SWING DOORS. SEE SECTION 1707.4.4.2
 FBC 2001.
 7-SEE PLANS FOR ADDITIONAL COMMENTS.
 8-AFTER CORECTIONS ARE DONE TO ORIGINAL
 DRAWINGS, PLEASE, RETURN OLD PLANS TO
 EXPEDITE REVIEW PROCESS.
 9-NEED 2 SETS OF PRODUCT APPROVALS FOR:
 A)GARAGE DOOR: DRAWINGS ARE NOT LEGIBLE.
 B)CEMENT TILE PRODUCT APPROVAL EXPIRED.
 C)STORM SHUTTERS NEED: *LEGIBLE DRAWINGS
 WITH DADE COUNTY APPROVAL STAMP.
 **KEY PLAN AND INSTALLATION SCHEDULE AND
 CHECK ON DRAWINGS SPECIFIC MOUNTING
 CONDITIONS AND ANCHOR TYPE AND SPACING
 TO BE USED IN THIS PROJECT.
 D)SITE SPECIFIC PRODUCT APPROVAL FOR
 DOORS AND WINDOWS NEED: *UPDATE BLDG
 CODE REFERENCE. NEED FBC 2001 OR ASCE
 7-98 NOT SFBC/ASCE 7-88.
 **USE UPDATE FORM FOR SITE SPECIFIC
 DOORS AND WINDOWS. SEE ATTACHED COPY.
 ***ENGINEER OF RECORD TO SIGN, SEAL AND
 DATE FORMS AS WELL. (REMAINDER: WRITE
 ALL HIS INFORMATION AS REQUIRED BY
 CHAPTER 471 OF FLORIDA STATUTES).
 10-CONTRACTOR TO UPDATE WORKERS COMP.
 INSURANCE.
 11-SEE ZONING AND MECHANICAL COMMENTS.
 12-TRUSS DRAWINGS: *TRUSS ENGINEER TO
 SIGN, SEAL AND DATE TRUSS LAYOUT AND
 ENGINEERED TRUSSES. (SEE CHAPTER 471
 FLORIDA STATUTES). COMPLETE ENGINEERED
 TRUSS PACKAGE TO BE ON THE JOB SITE
 FOR INSPECTOR'S INSPECTION.
 **TRUSS ENGINEERING TO INCLUDE DESIGN
 CRITERIA.
 ***ENGINEER OF RECORD TO REVIEW ALL
 TRUSS DRAWINGS PRIOR TO INSTALLATION.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-12-11 Cont ID  
Sent By btrobaug Date 2002-12-11 Time 17:46 Rev Time 1.00
Received By btrobaug Date 2002-12-11 Time 16:27 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-27 Cont ID  
Sent By btrobaug Date 2002-11-27 Time 12:27 Rev Time 0.00
Received By btrobaug Date 2002-11-27 Time 12:27 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-01-16 Cont ID  
Sent By pkrauss Date 2003-01-16 Time 13:34 Rev Time 0.25
Received By pkrauss Date 2003-01-16 Time 13:25 Sent To P
Notes
2003-01-16 00:00:00MECHANICAL PERMIT 02111900

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-12-12 Cont ID  
Sent By btrobaug Date 2002-12-11 Time 17:47 Rev Time 0.25
Received By pkrauss Date 2002-12-12 Time 12:08 Sent To P
Notes
2002-12-12 00:00:00DENIED:MECHANICAL PERMIT 02111900
  
 NO PLANS SUBMITTED FOR REVIEW.
  
 PROVIDE COMPLETED FORM 600 IN ACCORDANCE
 WITH 2001 FBC CHAPTER 13 SECTION 600.1.C
  
 PROVIDE INFORMATION ON THE EQUIPMENT
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-01-23 Cont ID  
Sent By kstevens Date 2003-01-23 Time 12:30 Rev Time 0.50
Received By kstevens Date 2003-01-23 Time 12:30 Sent To  
Notes
2003-01-23 00:00:00PASSED/PROVISO
  
 LAUNDRY TRAY MISSING FROM SANITARY RISER
 DIAGRAM - REVISION REQUIRED.

Review Stop P PLUMBING
Rev No 2 Status F Date 2003-01-18 Cont ID  
Sent By kstevens Date 2003-01-18 Time 07:15 Rev Time 0.33
Received By kstevens Date 2003-01-18 Time 07:15 Sent To B
Notes
2003-01-18 00:00:00DENIED
 REFERENCE: FBC-2001
  
 1) SANITARY RISER DIAGRAM DOES NOT RE-
 FLECT THE FLOOR PLAN.
 A) MASTER BATH DOES NOT SHOW 2ND LAV OR
 THE SHOWER.
 B) LAUNDRY ROOM DOES NOT SHOW LAUNDRY
 SINK.
 C) EXISTING BATH NOT SHOWN ON RISER AND
 THE NEW TUB IN NOT ON RISER.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status N Date 2002-12-17 Cont ID  
Sent By sgraham Date 2003-01-17 Time 15:53 Rev Time 0.25
Received By kstevens Date 2002-12-17 Time 15:21 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2003-01-17 Cont ID  
Sent By sgraham Date 2003-01-17 Time 15:53 Rev Time 0.00
Received By sgraham Date   Time   Sent To P
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2002-12-10 Cont ID  
Sent By btrobaug Date 2002-11-27 Time 12:27 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
2002-12-10 00:00:00DENIED PORT-COCHERE MUST BE 6' FROM THE
 GARAGE AS PER THE ZONING ADMIN-ROBIN
 SINGER