Plan Review Details - Permit 02111818
Plan Review Stops For Permit 02111818
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-12-12 Cont ID  
Sent By dpalmer Date 2002-12-11 Time 06:20 Rev Time 0.50
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-01-21 Cont ID  
Sent By dpalmer Date 2003-01-21 Time 13:26 Rev Time 0.50
Received By dpalmer Date 2003-01-21 Time 13:26 Sent To  
Notes
2003-01-21 00:00:00ELECTRICAL SERVICE BEING UPDATED TO
 300A UNDER OTHER PERMIT.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2003-01-06 Cont ID  
Sent By btrobaug Date 2003-01-14 Time 11:40 Rev Time 0.25
Received By dpalmer Date 2002-12-26 Time 06:11 Sent To P
Notes
2002-12-26 00:00:00**************UNSAT *************
  
 1)NOTE: PLEASE SEE LOAD CALCULATIONS
 SUBMITTED, LOAD IS SHOWN AT 223A W/ A
 200A METERCAN ENCLOSURE??
 PLEASE ALSO NOTE, LOAD CALCS STILL DO
 NOT INCLUDE HEAT PUMP IN LOAD AND
 SIZING OF UNIT.
 SPECS ARE SUBMITTED FOR HEAT PUMP SHOW-
 -ING 6 DIFFERENT SIZES????
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-12-11 Cont ID  
Sent By kstevens Date 2002-12-07 Time 07:59 Rev Time 0.25
Received By dpalmer Date 2002-12-11 Time 06:19 Sent To B
Notes
2002-12-11 00:00:00************** UNSAT ************
  
 1)NOTE: PLEASE SUBMIT SPECS/SPEC SHEET
 FOR NEW HEAT PUMP.SHOW EQUIPMENT
 AND LISTING.
  
 2)NOTE: PLEASE SUBMIT LOAD CALCULATIONS
 WITH NEW LOAD AND ALL EXISTING LOADS
 WITH SIZE OF EXISTING SERVICE. 215-5
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-01-14 Cont ID  
Sent By btrobaug Date 2003-01-14 Time 11:40 Rev Time 0.00
Received By btrobaug Date 2003-01-14 Time 11:40 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-26 Cont ID  
Sent By btrobaug Date 2002-11-26 Time 17:41 Rev Time 0.00
Received By btrobaug Date 2002-11-26 Time 17:41 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-01-07 Cont ID  
Sent By kstevens Date 2003-01-07 Time 09:18 Rev Time 0.33
Received By kstevens Date 2003-01-07 Time 09:15 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-12-07 Cont ID  
Sent By dpalmer Date 2003-01-06 Time 15:26 Rev Time 0.50
Received By kstevens Date 2002-12-07 Time 07:44 Sent To E
Notes
2002-12-07 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) FBC-2001 424.2.14.1 SWIMMING POOL
 WATER HEATERS SHALL BEAR THE LABEL OF A
 RECOGNIZED TESTING AGENCY. MANUFACTURE
 SHEETS REQUIRED. (SUBMITTAL)
 2) FBC-2001 424.2.14.2 WATER RETENTION,
 PROVIDE A POSITIVE MEANS OF RETAINING
 WATER IN THE HEATER WHEN PUMP IS SHUT
 OFF. (MANUFACTURE CUT SHEETS SUBMITTAL)
 3) FBC-2001 424.2.14.4 CONNECTIONS, ALL
 WATER HEATING EQUIPMENT SHALL BE INSTAL-
 LED WITH FLANGES OR UNION CONNECTIONS
 ADJACENT TO THE HEATER. (ADD TO NOTES)
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2002-12-03 Cont ID  
Sent By btrobaug Date 2002-11-26 Time 17:41 Rev Time 0.25
Received By sgraham Date   Time   Sent To P
Notes
***NONE***