Plan Review Details - Permit 02111609
Plan Review Stops For Permit 02111609
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-12-12 Cont ID  
Sent By jleech Date 2003-01-11 Time 12:44 Rev Time 0.50
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-01-06 Cont ID  
Sent By btrobaug Date 2003-01-06 Time 11:34 Rev Time 0.50
Received By btrobaug Date   Time   Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-12-11 Cont ID  
Sent By btrobaug Date 2003-01-03 Time 16:38 Rev Time 0.25
Received By dpalmer Date 2002-12-11 Time 06:08 Sent To B
Notes
2002-12-11 00:00:00************* UNSAT ***************
  
 1)NOTE: PLEASE SUBMIT LOAD CALCULATIONS
 WITH NEW HEAT PUMP LOAD BEING ADDED AND
 SHOW ALL EXISTING LOADS ALSO.
 PLEASE SHOW SIZE OF EXIST. SERVICE.
 215-5
  
 2)NOTE: PLEASE SEE RISER DIAGRAM FOR
 WIRING OF HEATER. PLEASE NOTE SUBMITTAL
 SHOW NEW HEAT PUMP MIN CIRCUIT AMPACITY
 AT 40AMPS, AND RISER SHOWS #12'S?
 PLEASE SEE 310-16 FOR RATING OF WIRE.
 AND OCP.
  
 3)NOTE: PLEASE SEE 250-122 FOR SIZING
 EQUIPMENT GROUND TO HEATER. SHOWN AS #12
 ALSO.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-01-03 Cont ID  
Sent By btrobaug Date 2003-01-03 Time 16:38 Rev Time 0.00
Received By btrobaug Date 2003-01-03 Time 16:38 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-22 Cont ID  
Sent By btrobaug Date 2002-11-22 Time 18:12 Rev Time 0.00
Received By btrobaug Date 2002-11-22 Time 18:12 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-01-11 Cont ID  
Sent By jleech Date 2003-01-11 Time 12:44 Rev Time 0.40
Received By jleech Date 2003-01-11 Time 12:44 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-12-06 Cont ID  
Sent By btrobaug Date 2003-01-06 Time 11:34 Rev Time 0.50
Received By kstevens Date 2002-12-06 Time 14:55 Sent To E
Notes
2002-12-06 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) FBC-2001 SEC 424.2.6.1 ENGINEERING
 DESIGN, CONSTRUCTION AND WORKMANSHIP.
 ANSI/NSPI-4 92, AND NSPI-5. (ADD TO
 NOTES)
 2) FBC-2001424.2.6.6.5 WHERE PROVIDED,
 THE VACUUM OR PRESSURE CLEANER FITTING
 SHALL BE LOCATED AT LEAST 6" AND NOT
 GREATER THAN 12" BELOW THE MINIMUM OPER-
 ATING WATER LEVEL OR AS AN ATTACHMENT TO
 THE SKIMMER. (SHOW DETAIL)
 3) FBC-2001 424.2.14.4 CONNECTIONS, ALL
 WATER HEATING EQUIPMENT SHALL BE INSTAL-
 LED WITH FLANGES OR UNION CONNECTIONS
 ADJACENT TO THE HEATER. (ADD TO NOTES)
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2002-11-26 Cont ID  
Sent By btrobaug Date 2002-11-22 Time 18:12 Rev Time 0.25
Received By sgraham Date   Time   Sent To P
Notes
***NONE***