Plan Review Details - Permit 02111609
Plan Review Stops For Permit 02111609 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2002-12-12 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2003-01-11 |
Time |
12:44 |
Rev Time |
0.50 |
Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2003-01-06 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-01-06 |
Time |
11:34 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
|
Time |
|
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2002-12-11 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-01-03 |
Time |
16:38 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2002-12-11 |
Time |
06:08 |
Sent To |
B |
|
Notes |
2002-12-11 00:00:00 | ************* UNSAT *************** | | | | 1)NOTE: PLEASE SUBMIT LOAD CALCULATIONS | | WITH NEW HEAT PUMP LOAD BEING ADDED AND | | SHOW ALL EXISTING LOADS ALSO. | | PLEASE SHOW SIZE OF EXIST. SERVICE. | | 215-5 | | | | 2)NOTE: PLEASE SEE RISER DIAGRAM FOR | | WIRING OF HEATER. PLEASE NOTE SUBMITTAL | | SHOW NEW HEAT PUMP MIN CIRCUIT AMPACITY | | AT 40AMPS, AND RISER SHOWS #12'S? | | PLEASE SEE 310-16 FOR RATING OF WIRE. | | AND OCP. | | | | 3)NOTE: PLEASE SEE 250-122 FOR SIZING | | EQUIPMENT GROUND TO HEATER. SHOWN AS #12 | | ALSO. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-01-03 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-01-03 |
Time |
16:38 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2003-01-03 |
Time |
16:38 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2002-11-22 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-11-22 |
Time |
18:12 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2002-11-22 |
Time |
18:12 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2003-01-11 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2003-01-11 |
Time |
12:44 |
Rev Time |
0.40 |
Received By |
jleech |
Date |
2003-01-11 |
Time |
12:44 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2002-12-06 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-01-06 |
Time |
11:34 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2002-12-06 |
Time |
14:55 |
Sent To |
E |
|
Notes |
2002-12-06 00:00:00 | DENIED | | REFERENCE: FBC-2001 424.2 SWIMMING POOLS | | | | A) PLEASE ADJUST YOUR NOTES, DETAILS, OR | | SUBMITTALS TO REFLECT THE FOLLOWING IN- | | FORMATION REQUIRED FOR PLAN REVIEW | | 1) FBC-2001 SEC 424.2.6.1 ENGINEERING | | DESIGN, CONSTRUCTION AND WORKMANSHIP. | | ANSI/NSPI-4 92, AND NSPI-5. (ADD TO | | NOTES) | | 2) FBC-2001424.2.6.6.5 WHERE PROVIDED, | | THE VACUUM OR PRESSURE CLEANER FITTING | | SHALL BE LOCATED AT LEAST 6" AND NOT | | GREATER THAN 12" BELOW THE MINIMUM OPER- | | ATING WATER LEVEL OR AS AN ATTACHMENT TO | | THE SKIMMER. (SHOW DETAIL) | | 3) FBC-2001 424.2.14.4 CONNECTIONS, ALL | | WATER HEATING EQUIPMENT SHALL BE INSTAL- | | LED WITH FLANGES OR UNION CONNECTIONS | | ADJACENT TO THE HEATER. (ADD TO NOTES) | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2002-11-26 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-11-22 |
Time |
18:12 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
P |
|
Notes |
|
|
|