Plan Review Details - Permit 02111133
Plan Review Stops For Permit 02111133
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-12-04 Cont ID  
Sent By jwitmer Date 2002-12-04 Time 11:46 Rev Time 3.00
Received By jwitmer Date   Time   Sent To  
Notes
2002-12-04 00:00:00 
 *** ISSUED PERMIT***
 -PLAN REVIEW HISTORY-
  
 PERMIT# 02111133
 ADDRESS: 720 22ND ST
 CONT: KENACO
 TELL # (561)315-5077 (RICK)
  
 THE ATTACHED COMMENTS ARE PART OF THE
 PERMIT AND PLAN REVIEW PACKAGE AND ARE
 NOT TO BE REMOVED FROM THE ISSUED SET OF
 PLANS.104.2.1.2 ADMINISTRATIVE CODE.
 *****PROVISO*****
  
 1)1015.2 HEIGHT. GUARDRAILS SHALL
 FORM A VERTICAL PROTECTIVE BARRIER NOT
 LESS THAN 42" HIGH.
 1)1015.3 OPENINGS. OPEN GUARDRAILS
 SHALL HAVE INTERMEDIATE RAILS OR ORNA-
 MENTAL PATTERNS SUCH AS A 4" DIAMETER
 SPHERE CAN NOT PASS THROUGH. A BOTTOM
 RAIL OR CURB SHALL BE PROVIDED THAT WILL
 REJECT THE PASSAGE OF 2" DIAMETER
 SPHERE.
  
 2)1608.2.3 THE GUARDRAIL SYSTEM SHALL
 BE DESIGNED AND CONSTRUCTED TO RESIST A
 200 LB CONCENTRATED HORIZONTAL LOAD
 APPLIED ON A 1 SQ FT AREA AT ANY POINT
 IN THE SYSTEM INCLUDING INTERMEDIATE
 RAILS OR OTHER ELEMENTS SERVING THIS
 PURPOSE.
  
 3) STAIRS FBC 1007.3.1 2R+1T=24-25"
  
 4)FOUNDATION/ STEMWALL:
 FBC 1804.1.3 THE BOTTOM OF THE FOOTER A
 MINIMUM OF 12" DEEP.
 FBC 2304.3.4 STEMWALL 18"FROM GRADE TO
 BOTTOM OF FLOOR JOIST.
 BUILDING PLAN REVIEW
 JIM WITMER

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-12-03 Cont ID  
Sent By btrobaug Date 2002-12-03 Time 15:46 Rev Time 0.50
Received By btrobaug Date 2002-12-03 Time 12:12 Sent To R
Notes
2002-12-03 00:00:00PROVISO
 ~~~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 ELECTRICAL PERMIT REQUIRED.THE
 ELECTRICAL CONTRACTOR SHALL PROVIDE A
 RISER DIAGRAM AND AIC RATINGS WITH
 APPLICATION.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/659-8096EXT. 8392

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2002-11-26 Cont ID  
Sent By btrobaug Date 2002-11-26 Time 17:38 Rev Time 0.00
Received By btrobaug Date 2002-11-26 Time 17:37 Sent To Z
Notes
2002-11-26 00:00:00NEW SURVEY BROUGHT IN BY CONTRACTOR, NOT
 REQUESTED./WRT

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-18 Cont ID  
Sent By btrobaug Date 2002-11-18 Time 17:57 Rev Time 0.00
Received By btrobaug Date 2002-11-18 Time 17:57 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-12-03 Cont ID  
Sent By pkrauss Date 2002-12-03 Time 16:03 Rev Time 0.20
Received By pkrauss Date 2002-12-03 Time 16:03 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2002-12-04 Cont ID  
Sent By jwitmer Date 2002-12-04 Time 11:42 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2002-12-04 Cont ID  
Sent By btrobaug Date 2002-12-03 Time 15:46 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2002-12-03 Cont ID  
Sent By btrobaug Date 2002-11-26 Time 17:39 Rev Time 0.25
Received By sgraham Date   Time   Sent To B
Notes
***NONE***