Plan Review Details - Permit 02110853
Plan Review Stops For Permit 02110853
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-12-17 Cont ID  
Sent By hmoser Date 2002-12-14 Time 13:27 Rev Time 0.50
Received By btrobaug Date 2002-12-17 Time 08:11 Sent To R
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-05-08 Cont ID  
Sent By shernand Date 2003-05-08 Time 14:29 Rev Time 0.00
Received By shernand Date 2003-05-08 Time 14:29 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-05-02 Cont ID  
Sent By shernand Date 2003-05-02 Time 18:05 Rev Time 0.00
Received By shernand Date 2003-05-02 Time 18:05 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-15 Cont ID  
Sent By dpalmer Date 2002-11-15 Time 09:06 Rev Time 0.00
Received By dpalmer Date 2002-11-15 Time 09:06 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-05-16 Cont ID  
Sent By pkrauss Date 2003-05-16 Time 14:45 Rev Time 0.30
Received By pkrauss Date 2003-05-16 Time 14:29 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2003-05-07 Cont ID  
Sent By shernand Date 2003-05-08 Time 14:29 Rev Time 0.20
Received By pkrauss Date 2003-05-07 Time 15:38 Sent To  
Notes
2003-05-07 00:00:00REVISED PLAN SUBMITTED WAS THE WRONG
 FLOOR PLAN - SHOULD BE GARAGE LEFT, PLAN
 SUBMITTED IS GARAGE RIGHT.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-12-14 Cont ID  
Sent By shernand Date 2003-05-02 Time 18:05 Rev Time 0.33
Received By hmoser Date 2002-12-14 Time 13:27 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-12-04 Cont ID  
Sent By jleech Date 2002-12-04 Time 19:12 Rev Time 0.25
Received By jleech Date 2002-12-04 Time 19:12 Sent To M
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2002-12-17 Cont ID  
Sent By btrobaug Date 2002-12-17 Time 08:23 Rev Time 2.00
Received By jgomez Date 2002-12-17 Time 12:10 Sent To  
Notes
2002-12-17 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS UNDER A SEPARATE PERMIT.
 2-FLOOD ZONE A8: WILL NEED THE ELEVATION
 CERTIFICATE.
 3-SPECIFY SIZE OF ANCHOR BOLT AND WASHER
 FOR GARAGE DOOR STRUCTURAL BUCK DETAIL
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 4-CLARIFY HOW DOES THE 34SH WINDOWS
 PROVIDE THE 24" MIN. CLEAR HEIGHT.
 ALSO, DOES THE 24+5 SH WINDOW PROVIDE
 5.7 S.F. MIN. CLEAR OPENING? CLARIFY.
 SEE SEC. 1005.4.4 FBC 2001.
 5-DETAIL S21 DOESN'T WORK AT CONNECTION
 OF COLUMN P1 LOCATED BETWEEN GARAGE
 AND STAIRWAY. REVISE AS REQ'D. SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 6-REVISE CONNECTOR TC-1 SPECIFIED ON
 ROOF FRAMING PLAN AT FRONT ELEVATION.
 NEED WOOD TO WOOD CONNECTORS. SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.

Review Stop Z ZONING
Rev No 1 Status P Date 2002-12-17 Cont ID  
Sent By dpalmer Date 2002-11-15 Time 09:06 Rev Time 0.00
Received By jgomez Date 2002-12-17 Time 12:09 Sent To  
Notes
2002-12-17 00:00:00APPROVED BY ZONING 11-18-02. SEE SURVEY.