Plan Review Details - Permit 02110587
Plan Review Stops For Permit 02110587
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-01-31 Cont ID  
Sent By dpalmer Date 2003-01-31 Time 09:08 Rev Time 0.50
Received By dpalmer Date 2003-01-31 Time 09:08 Sent To  
Notes
2003-01-31 00:00:00OK PER LEA SMITH

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-01-31 Cont ID  
Sent By dpalmer Date 2003-01-31 Time 09:08 Rev Time 0.00
Received By dpalmer Date 2003-01-31 Time 09:07 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2003-01-30 Cont ID  
Sent By dpalmer Date 2003-01-30 Time 06:43 Rev Time 0.25
Received By dpalmer Date 2003-01-30 Time 06:43 Sent To B
Notes
2003-01-30 00:00:00*********** UNSAT ************
  
 1)NOTE: PLEASE NOTE, PER FS/FAC PLANS
 MUST CONTAIN ORIGINAL SIGNATURE BY THE
 ENGINEER OF RECORD. SIGNATURE MAY NOT BE
 A PHOTO COPY AND THEN RE-SEALED.
 471.025
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-11-25 Cont ID  
Sent By kstevens Date 2003-01-24 Time 13:09 Rev Time 0.25
Received By dpalmer Date 2002-11-25 Time 05:47 Sent To B
Notes
2002-11-25 00:00:00******************* UNSAT *************
  
 1)NOTE: PLEASE NOTE, HEAT PAUMP NEEDS
 TO BE INCLUDED ON WIRING DIAGRAM.
 WIRE/PIPE ETC.
  
 2)NOTE: PLEASE SUBMIT LOAD CALCULATIONS,
 TO INCLUDE EXISTING AND NEW HEAT PUMP.
 PLEASE SHOW SIZE OF EXISTING SERVICE.
  
 PLEAASE NOTE, ANY CHANGES TO PLANS, MUST
 BE DONE BY THE ENGINEER OF RECORD.
 471 FS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-08 Cont ID  
Sent By btrobaug Date 2002-11-08 Time 16:31 Rev Time 0.00
Received By btrobaug Date 2002-11-08 Time 16:31 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-01-24 Cont ID  
Sent By kstevens Date 2003-01-24 Time 13:09 Rev Time 0.33
Received By kstevens Date 2003-01-24 Time 13:09 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-11-20 Cont ID  
Sent By sgraham Date 2002-11-18 Time 12:49 Rev Time 0.75
Received By kstevens Date 2002-11-20 Time 09:48 Sent To E
Notes
2002-11-20 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) COMPLY WITH FBC-2001 SEC 424.2
 PRIVATE SWIMMING POOLS. (ADD TO NOTES)
 2) FBC-2001424.2.6.6.2 SHOW COMPLIANCE
 WITH ANSI/ASME A112.19.8M. PROVIDE MODEL
 NUMBER AND MANUF INFO FOR VAC LOCK.
 (GIVE DETAIL OR ADD NOTE)(SUBMITTAL)
 3) FBC-2001 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 4) FBC-2001 424.2.14.4 CONNECTIONS, ALL
 WATER HEATING EQUIPMENT SHALL BE INSTAL-
 LED WITH FLANGES OR UNION CONNECTIONS
 ADJACENT TO THE HEATER. (ADD TO NOTES)
 5) SECTION 104.2 - DRAWINGS SHALL BE OF
 SUFFICIENT CLARITY. COPIES OF COPIES ARE
 GETTING DIFFICULT TO READ FOR DETAILS
 AND NOTES.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2002-11-18 Cont ID  
Sent By btrobaug Date 2002-11-08 Time 16:31 Rev Time 0.25
Received By sgraham Date   Time   Sent To P
Notes
***NONE***