Plan Review Details - Permit 02110163
Plan Review Stops For Permit 02110163
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
2003-02-04 00:00:00REV DATED 12/17/03

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-11-19 Cont ID  
Sent By hpiskura Date 2002-11-19 Time 14:54 Rev Time 0.00
Received By hpiskura Date 2002-11-19 Time 14:43 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-11-13 Cont ID  
Sent By hpiskura Date 2002-11-13 Time 08:21 Rev Time 0.00
Received By hpiskura Date 2002-11-13 Time 07:18 Sent To  
Notes
2002-11-13 00:00:00THE DOOR EXITING "OPEN OFFICE 124" ON
 THE SOUTH SIDE OF THE TOILET ROOMS
 SHOWN AS "EXT" IS REQUIRED TO SWING IN
 THE DIRECTION OF EXIT TRAVEL.SEE FBC
 1012.1.2 AND FBC 1012.1.4.
  
 THE DOOR AND SIDE LIGHT SHOWN AS 109
 NEAR THE NORTH STAIR IS REQUIRED TO BE
 FIRE RATED.SEE FBC 1010.1.
  
 SHOW THE DESIGN WIND PRESSURE FOR THE
 NEW STORE FRONT DOOR.SEE FBC 1606.1.7.
  
 IF THE TEST REPORTS AND/OR NOTICE OF
 ACCEPTANCE REPORTS ARE NOT INCLUDED
 WITH THIS PERMIT APPLICATION, A
 SEPARATE PERMIT, PLANS AND FEES WILL BE
 REQUIRED.

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2003-02-04 Cont ID  
Sent By dpalmer Date 2003-02-04 Time 14:27 Rev Time 0.25
Received By dpalmer Date 2003-02-04 Time 14:27 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-11-21 Cont ID  
Sent By dpalmer Date 2002-11-21 Time 05:41 Rev Time 0.50
Received By dpalmer Date 2002-11-21 Time 05:41 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2002-11-19 Cont ID  
Sent By dpalmer Date 2002-11-19 Time 10:22 Rev Time 0.50
Received By dpalmer Date 2002-11-19 Time 10:20 Sent To  
Notes
2002-11-19 00:00:00***************** UNSAT ****************
  
 1)NOTE: PLEASE NOTE RISER DIAGRAM AND
 PANEL SCHEDULE DO NOT CORRELATE FOR
 "H1B". PLEASE NOTE, ORIG SHEET SHOWS
 RISER AS "H2B. PLEASE NOTE RISER IS
 NOW CHANGED BUT PANEL SCHEDULE FOR TRANS
 -FORMER SHOWS ,, PANEL "LA" FED THRU
 TRANSFORMER "TB1". PLEASE SEE RISER
 DIAGRAM, PANEL LA IS SHOWN AS PART OF
 EXSITING SERVICE? X-FORMER IS ALSO
 SHOWN AS T1B? PLEASE NOTE RISER DIAGRAM
 SHOWS NEW TRANSFORMER " T1C" AND L1B,
 L1C, ETC.
  
 2)NOTE: PLEASE NOTE, NOT #2 FROM FIRST
 REVIEW NEEDS TO BE ADDRESSED. PLEASE
 CLARIFY REQ`D RECEPT FOR A/C UNITS
 PER 210-63.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-11-13 Cont ID  
Sent By dpalmer Date 2002-11-13 Time 06:27 Rev Time 0.75
Received By dpalmer Date 2002-11-13 Time 06:27 Sent To  
Notes
2002-11-13 00:00:00**************** UNSAT **************
  
 1)NOTE: PLEASE NOTE, RISER DIAGRAM
 AND SUBMITTED PANEL SCHEDULES DO NOT
 CORRELATE. MISSING PANEL "H2B, MISSING
 "L2C", LOAD CALCULATIONS,CIRCUIT #`S
 WIRE SIZES ETC.
 PLEASE NOTE, THERE ARE PANEL SCHEDULES
 SUBMITTED NOT ON RISER? "H1B", PLEASE
 CLARIFY.215-5
 PLEASE NOTE AT THIS TIME A COMPLETE
 REVIEW OF WIRE/OCP/LOADS CAN NOT BE DONE
 UNTIL RISER/PLANS/SCHEDULES CORRELATE.
  
 2)NOTE: PLEASE NOTE/CLARIFY RECEPT REQ`D
 FOR A/C EQUIPMENT ON ROOFTOP. NEW/ EXIST
 ? 210-63
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2003-02-06 Cont ID  
Sent By nmccray Date 2003-02-06 Time 10:30 Rev Time 0.00
Received By nmccray Date 2003-02-06 Time 10:29 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2002-11-19 Cont ID  
Sent By mcarsill Date 2002-11-19 Time 11:05 Rev Time 0.00
Received By mcarsill Date 2002-11-19 Time 11:05 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2002-11-13 Cont ID  
Sent By mcarsill Date 2002-11-13 Time 13:04 Rev Time 0.00
Received By mcarsill Date 2002-11-13 Time 13:04 Sent To  
Notes
2002-11-13 00:00:001) DOOR LEADING FROM OPEN OFFICE 124
 SWINGS IN THE WRONG DDIRECTION.
  
 2) DOOR 109 AND EXISTING STAIR DOOR
 APPEAR TO OPPOSE ONE ANOTHER.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT.8497
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-01-30 Cont ID  
Sent By btrobaug Date 2003-01-30 Time 14:58 Rev Time 0.00
Received By btrobaug Date 2003-01-30 Time 14:57 Sent To  
Notes
2003-01-30 00:00:00TO COMM BOARD #19./WRT

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-20 Cont ID  
Sent By btrobaug Date 2002-11-20 Time 18:05 Rev Time 0.00
Received By btrobaug Date 2002-11-20 Time 18:05 Sent To  
Notes
2002-11-20 00:00:00TO COMM BOARD,# 31

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-11-21 Cont ID  
Sent By pkrauss Date 2002-11-21 Time 15:31 Rev Time 0.35
Received By pkrauss Date 2002-11-21 Time 15:23 Sent To  
Notes
2002-11-21 00:00:00MECHANICAL PERMIT 02110170

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-11-13 Cont ID  
Sent By pkrauss Date 2002-11-13 Time 12:51 Rev Time 0.45
Received By pkrauss Date 2002-11-13 Time 10:34 Sent To  
Notes
2002-11-13 00:00:00PROVISO:MECHANICAL PERMIT 02110170
  
 PLEASE NOTE - PLAN SHEET M2.2, EXISTING
 DUCTWORK PENETRATING THE WALL AT OFFICE
 #211 & ALSO WHERE DUCT PENETRATES THE
 CORRIDOR, FIRE DAMPERS ARE NOT INDICATED
 IN THESE AREAS (THEY SHOULD BE EXISTING)
 SHOULD FIRE DAMPERS NOT BE IN PLACE THEY
 ARE REQUIRED.
  
 PROVIDE MANUFACTURER INSTALLATION
 INSTRUCTIONS FOR THE FIRE DAMPERS ON THE
 JOBSITE AT THE TIME OF INSPECTION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-02-11 Cont ID  
Sent By kstevens Date 2003-02-11 Time 11:49 Rev Time 0.10
Received By kstevens Date 2003-02-11 Time 11:49 Sent To  
Notes
2003-02-11 00:00:00REVISION OK

Review Stop P PLUMBING
Rev No 2 Status F Date 2003-02-06 Cont ID  
Sent By kstevens Date 2003-02-06 Time 07:41 Rev Time 0.75
Received By kstevens Date 2003-02-05 Time 18:53 Sent To  
Notes
2003-02-06 00:00:00REVISION DENIED
  
 1) PER TABLE 403.1 A DRINKING FOUNTAIN
 IS REQUIRED.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-11-08 Cont ID  
Sent By kstevens Date 2002-11-08 Time 10:11 Rev Time 1.00
Received By kstevens Date 2002-11-08 Time 10:11 Sent To  
Notes
***NONE***