Plan Review Details - Permit 02110132
Plan Review Stops For Permit 02110132
Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-01-28 Cont ID  
Sent By btrobaug Date 2003-01-28 Time 09:52 Rev Time 0.50
Received By btrobaug Date 2003-01-28 Time 09:52 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-12-12 Cont ID  
Sent By dpalmer Date 2002-12-12 Time 06:36 Rev Time 0.33
Received By dpalmer Date 2002-12-12 Time 06:36 Sent To P
Notes
2002-12-12 00:00:00************* NOTES REDLINED*****
  
 1)NOTE: PLEASE SEE TWO SD'D LOCATED
 INSIDE MASTER BEDROOM. PLEASE SEE PLAN
 FOR LOCATION OF 2ND SD MOVED TO BE
 OUTSIDE. NFPA-72 8-1.4
  
 2)NOTE: SEE BATH GFI TO BE W/IN 3'
 OF SINK. 210-52D
  
  
 PLEASE SUBMIT REVISED AND OPTIIONS
 BEFORE ROUGH.IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-11-14 Cont ID  
Sent By btrobaug Date 2002-12-10 Time 18:19 Rev Time 0.25
Received By dpalmer Date 2002-11-14 Time 10:50 Sent To P
Notes
2002-11-14 00:00:00*************** UNSAT **************
  
 1)NOTE: PLEASE NOTE DO NOT CORRELATE
 WITH MASTER PLANS.02041269
  
 2)NOTE: MISSING ARC FAULT PROTECTION
 FOR BEDROOM CRICUITS PER 210-12
  
 3)NOTE: MISSING REQ`D BATH CIRCUIT(S)
 PER 210-11-C-3
  
 4)NOTE: PLEASE SEE DRYER SHOWN AT 1-POLE
 20A BRKR.
  
 PLEASE SEE PLANS, OTHER CHANGES WERE
 MADE ALSO.
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW.
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EDXT 8372

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2002-12-27 Cont ID  
Sent By dpalmer Date 2002-12-27 Time 14:50 Rev Time 0.00
Received By dpalmer Date 2002-12-27 Time 14:50 Sent To B
Notes
2002-12-27 00:00:00TO ROBRT BROWN DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2002-12-10 Cont ID  
Sent By btrobaug Date 2002-12-10 Time 18:19 Rev Time 0.00
Received By btrobaug Date 2002-12-10 Time 18:19 Sent To E
Notes
2002-12-10 00:00:00TO DVP./WRT.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-04 Cont ID  
Sent By btrobaug Date 2002-11-04 Time 18:35 Rev Time 0.00
Received By btrobaug Date 2002-11-04 Time 18:35 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-11-25 Cont ID  
Sent By rbrown Date 2002-11-25 Time 12:04 Rev Time 0.00
Received By rbrown Date 2002-11-25 Time 12:04 Sent To  
Notes
2002-11-25 00:00:00PLANS SAME AS MASTER PERMIT # 02041269

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-02-03 Cont ID  
Sent By kstevens Date 2003-02-03 Time 16:41 Rev Time 0.50
Received By kstevens Date 2003-02-03 Time 16:40 Sent To  
Notes
2003-02-03 00:00:00REVISION OK - SANT. RISER DIAGRAM -
 FLOOR PLAN

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-12-17 Cont ID  
Sent By kstevens Date 2002-12-17 Time 18:33 Rev Time 0.25
Received By kstevens Date 2002-12-17 Time 18:33 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-11-20 Cont ID  
Sent By dpalmer Date 2002-12-12 Time 06:37 Rev Time 0.25
Received By kstevens Date 2002-11-20 Time 18:58 Sent To R
Notes
2002-11-20 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) SHT A-02 RISER DIAGRAM FOR MASTER
 BATH, LAV AT SHOWER NOT VENTED.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2003-01-07 Cont ID  
Sent By rbrown Date 2003-01-07 Time 11:07 Rev Time 0.00
Received By rbrown Date 2003-01-07 Time 11:07 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-12-30 Cont ID  
Sent By kstevens Date 2002-11-20 Time 18:59 Rev Time 0.00
Received By rbrown Date 2002-11-25 Time 12:05 Sent To  
Notes
2002-12-30 00:00:00SURVEY DRAWING SHOWS MODEL D BUT
 APPLICATION AND PLANS ARE MODEL E.
 NEED A REVISED SURVEY DRAWING.

Review Stop Z ZONING
Rev No 1 Status P Date 2002-11-13 Cont ID  
Sent By btrobaug Date 2002-11-04 Time 18:35 Rev Time 0.25
Received By sgraham Date   Time   Sent To P
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy