Plan Review Details - Permit 02110127
Plan Review Stops For Permit 02110127
Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-01-28 Cont ID  
Sent By btrobaug Date 2003-01-28 Time 09:43 Rev Time 0.50
Received By btrobaug Date 2003-01-28 Time 09:43 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-12-12 Cont ID  
Sent By dpalmer Date 2002-12-12 Time 06:50 Rev Time 0.33
Received By dpalmer Date 2002-12-12 Time 06:50 Sent To P
Notes
2002-12-12 00:00:00************* NOTES REDLINED ********
  
 1)NOTE: PLEASE SEE PLAN, OCP FOR DRYER
 STILL SHOWN AT 1-P20A???? PLEASE REVISE.
  
 2)NOTE: PLEASE SEE LOCATION OF SD ON
 SECOND FLR HALL. PLEASE MOVE SD OR ADD
 SECOND TO MEET NFPA-72 OUTSIDE ALL
 BEDROOMS IN THE IMMEDIATE VICINITY.
 8-1.4
  
 PLEASE REVISE AND SHOW ALL OPTIONS AND
 SUBMIT REVISED PLANS BEFORE ROUGH.
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-11-14 Cont ID  
Sent By btrobaug Date 2002-12-10 Time 18:18 Rev Time 0.25
Received By dpalmer Date 2002-11-14 Time 07:34 Sent To P
Notes
2002-11-14 00:00:00************** UNSAT ******************
  
 1)NOTE: PLEASE NOTE, PLANS DO NOT
 CORRELATE TO MASTER PLANS UNDER 02041264
  
 2)NOTE: PLEASE NOTE DEDICATED BATH(S)
 CIRCUITS HAVE BEEN REMOVED. 210-52D
 210-11-C3
  
 3)NOTE: PLEAS ALSO NOTE THE REQ`D
 DEDICATED ARC FAULT CIRCUITS PER 210-12
 HAVE BEEN REMOVED?
  
 4)NOTE: PLEASE NOTE DRYER SHOWN AS
 1-POLE 20A?
  
 PLEASE NOTE OTHER ITEMS ON PLANS THAT
 HAVE BEEN CHANGED.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2002-12-27 Cont ID  
Sent By dpalmer Date 2002-12-27 Time 15:01 Rev Time 0.00
Received By dpalmer Date 2002-12-27 Time 15:01 Sent To P
Notes
2002-12-27 00:00:00TO PLUMB INBOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2002-12-10 Cont ID  
Sent By btrobaug Date 2002-12-10 Time 18:17 Rev Time 0.00
Received By btrobaug Date 2002-12-10 Time 18:16 Sent To E
Notes
2002-12-10 00:00:00TO DVP./WRT

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-04 Cont ID  
Sent By btrobaug Date 2002-11-04 Time 18:37 Rev Time 0.00
Received By btrobaug Date 2002-11-04 Time 18:37 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-11-25 Cont ID  
Sent By rbrown Date 2002-11-25 Time 15:06 Rev Time 0.00
Received By rbrown Date 2002-11-25 Time 15:06 Sent To  
Notes
2002-11-25 00:00:00PLANS SAME AS MASTER PERMIT # 02041264

Review Stop P PLUMBING
Rev No 4 Status P Date 2003-02-03 Cont ID  
Sent By kstevens Date 2003-02-03 Time 16:59 Rev Time 0.50
Received By kstevens Date 2003-02-03 Time 16:58 Sent To  
Notes
2003-02-03 00:00:00REVISION OK - SANT. RISER DIAGRAM -
 FLOOR PLAN

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-01-06 Cont ID  
Sent By pschmitz Date 2003-01-06 Time 15:02 Rev Time 75.00
Received By pschmitz Date   Time   Sent To B
Notes
2003-01-06 00:00:00REVISION, APPR, PES.

Review Stop P PLUMBING
Rev No 2 Status F Date 2002-12-17 Cont ID  
Sent By dpalmer Date 2002-12-27 Time 15:01 Rev Time 0.25
Received By kstevens Date 2002-12-17 Time 18:45 Sent To  
Notes
2002-12-17 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) COMMENT FROM PREVIOUS REVIEW NOT
 ADDRESSED
 MASTER BATH SANITARY RISER DIAGRAM, SHT
 A-02, AND FLAT DRAWING SHT A-03 DO NOT
 MEET CODE. SEPARATE RISERS ARE REQUIRED
 FOR EACH LAV.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-11-20 Cont ID  
Sent By dpalmer Date 2002-12-12 Time 06:52 Rev Time 0.25
Received By kstevens Date 2002-11-20 Time 19:10 Sent To R
Notes
2002-11-20 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) MASTER BATH SANITARY RISER DIAGRAM,
 SHEET A-02, AND FLAT DRAWING SHT A-03
 DO NOT MEET CODE. SEPARATE RISERS ARE
 REQUIRED FOR EACH LAV. ALSO SHOWS 1-1/2"
 AT STACK ON SHEET A-03. ??
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2002-11-25 Cont ID  
Sent By kstevens Date 2002-11-20 Time 19:22 Rev Time 0.00
Received By rbrown Date 2002-11-25 Time 15:47 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2002-11-13 Cont ID  
Sent By btrobaug Date 2002-11-04 Time 18:37 Rev Time 0.25
Received By sgraham Date   Time   Sent To P
Notes
***NONE***