Plan Review Stops For Permit 02110123 |
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2003-01-28 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-01-28 |
Time |
09:27 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2003-01-28 |
Time |
09:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2002-12-12 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-12-12 |
Time |
06:18 |
Rev Time |
0.30 |
Received By |
dpalmer |
Date |
2002-12-12 |
Time |
06:18 |
Sent To |
P |
|
Notes |
2002-12-12 00:00:00 | *********** NOTES REDLINED ******** | | | | PLEASE SEE PLANS FOR THE FOLLOWING. | | | | 1)NOTE: PLEASE NOTE DRYER STILL SHOWN | | AS 1-POLE 20A OCP FOR 5KW 240V CIRCUIT? | | PLEASE REVISE. | | | | 2)NOTE: SD ON SECOND FLR HALL NEEDS TO | | MOVED FROM LOCATION SHOWN OR ADD ANOTHER | | OUTSIDE BEDROOMS 2&3. | | | | | | PLEASE SUBMIT THE ABOVE REVISED AND | | SHOW ALL "OPTIONS" INSTALLED BEFORE | | ROUGH. IF THERE ARE ANY QUESTIONS | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2002-11-14 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-12-10 |
Time |
18:21 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2002-11-14 |
Time |
10:30 |
Sent To |
P |
|
Notes |
2002-11-14 00:00:00 | **************** UNSAT **************** | | | | 1)NOTE: PLEASE NOTE PLANS DO NOT | | CORRELATE WITH MASTER PLANS 02041464. | | | | 2)NOTE: MISSING ARC FAULT PROETCTION | | REQ`D FOR BEDROOMS PER 210-12 | | | | 3)NOTE: MISSING REQ`D DEDICATED BATH | | CIRCUIT(S) PER 210-52D/210-11-C3 | | | | 4)NOTE: PLEASE SEE DRYER SHOW AT 1-POLE | | 20A BRKR? | | | | PLEASE SEE PLANS AND SEE OTHER CHANGES | | ON PLANS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW. | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2002-12-27 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-12-27 |
Time |
15:02 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2002-12-27 |
Time |
15:02 |
Sent To |
P |
|
Notes |
2002-12-27 00:00:00 | TO PLUMB INBOX. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2002-12-10 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-12-10 |
Time |
18:21 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2002-12-10 |
Time |
18:21 |
Sent To |
E |
|
Notes |
2002-12-10 00:00:00 | TO DVP./WRT |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2002-11-04 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-11-04 |
Time |
18:31 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2002-11-04 |
Time |
18:31 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2002-11-25 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2002-11-25 |
Time |
16:20 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2002-11-25 |
Time |
16:20 |
Sent To |
|
|
Notes |
2002-11-25 00:00:00 | PLANS SAME AS MASTER PERMIT #02041264 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2003-02-03 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-02-03 |
Time |
16:56 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2003-02-03 |
Time |
16:56 |
Sent To |
|
|
Notes |
2003-02-03 00:00:00 | REVESION OK - SANT. RISER DIAGRAM - | | FLOOR PLAN |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2003-01-06 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2003-01-06 |
Time |
15:16 |
Rev Time |
75.00 |
Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
B |
|
Notes |
2003-01-06 00:00:00 | REVISION APPR, PES. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2002-12-17 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-12-27 |
Time |
15:02 |
Rev Time |
0.25 |
Received By |
kstevens |
Date |
2002-12-17 |
Time |
18:38 |
Sent To |
|
|
Notes |
2002-12-17 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | | | 1) COMMENT FROM PREVIOUS REVIEW NOT ADD- | | RESSED. | | MASTER BATH SANITARY RISER DIAGRAM SHT | | A-02 AND FLAT DRAWING SHT A-03 DO NOT | | MEET CODE. SEPARATE STACKS ARE REQUIRED | | FOR EACH LAV. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2002-11-20 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-12-12 |
Time |
06:24 |
Rev Time |
0.25 |
Received By |
kstevens |
Date |
2002-11-20 |
Time |
18:32 |
Sent To |
B |
|
Notes |
2002-11-20 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | | | 1) MASTER BATH SANITARY RISER DIAGRAM, | | SHEET A-02 AND FLAT DRAWING SHEET A-03 | | DO NOT MEET CODE. SEPARATE RISERS ARE | | REQUIRED FOR EACH LAV. ALSO SHOWS 1-1/2" | | AT STACK ON SHEET A-03. ?? | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2002-11-25 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2002-11-25 |
Time |
16:21 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2002-11-25 |
Time |
16:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-11-04 |
Time |
18:31 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
P |
|
Notes |
|
|