Plan Review Stops For Permit 02102229 |
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2003-04-21 |
Time |
12:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2003-04-08 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-15 |
Time |
13:40 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2003-04-08 |
Time |
14:24 |
Sent To |
|
|
Notes |
2003-04-08 00:00:00 | ********* UNSAT ************* | | | | 1)NOTE: PLEASE SEE NOTES FROM FIRST | | REVIEW/REDLINED. | | PLEASE SIZE AWG/OCP FOR AHU #2. 10KW W/ | | #10 AND 2P-25. | | | | 2)NOTE: PLEASE SEE MISSING RECEPT PER | | 210-52 | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2002-11-27 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-04-01 |
Time |
09:32 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2002-11-27 |
Time |
16:02 |
Sent To |
M |
|
Notes |
2002-11-27 00:00:00 | ********** NOTES ******** | | PLANS REDLINED, OCP FOR AHU SHOWN AT 2P | | -25A FOR 10KW LOAD. NEEDS TO BE SIZED | | AT 125% MIN PER 424-3 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2003-04-15 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-15 |
Time |
13:40 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-04-15 |
Time |
13:40 |
Sent To |
E |
|
Notes |
2003-04-15 00:00:00 | DP DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-04-01 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-04-01 |
Time |
09:32 |
Rev Time |
0.00 |
Received By |
sthyng |
Date |
2003-04-01 |
Time |
09:32 |
Sent To |
E |
|
Notes |
2003-04-01 00:00:00 | TO DP DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2002-12-13 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-12-13 |
Time |
18:21 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2002-12-13 |
Time |
18:21 |
Sent To |
R |
|
Notes |
2002-12-13 00:00:00 | ROB M./WRT |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2002-11-04 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-11-04 |
Time |
09:26 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2002-11-04 |
Time |
09:25 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2002-11-30 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-11-27 |
Time |
16:02 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2002-11-30 |
Time |
09:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2002-11-18 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2002-11-04 |
Time |
16:03 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2002-11-18 |
Time |
20:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2002-12-16 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2002-12-16 |
Time |
15:55 |
Rev Time |
3.00 |
Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-12-16 00:00:00 | BUILDING PROVISO | | | | 1) SUBMIT SIGNED AND SEALED ENGINEERED | | DRAWINGS FOR THE HANGER CONNECTOR SHOWN | | IN DETAIL D ON S2. | | | | 2)PROVIDE (2) CURRENT AND COMPLETE | | COPIES OF SBCCI OR METRO-DADE PRODUCT | | APPROVALS FOR THE OVAL AND ARCHED TOP | | FIXED GLASS WINDOWS. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2002-12-05 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-12-13 |
Time |
18:21 |
Rev Time |
4.00 |
Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-12-05 00:00:00 | BUILDING DENIED | | | | 1) FL BLD CODE 1804.2.2 QUESTIONABLE | | SOILS, WHERE THE BEARING CAPACITY IS | | NOT DEFINETLY KNOWN OR IS IN QUESTION. | | PROVIDE A SIGNED AND SEALED SOIL TEST | | REPORT FROM A SOIL ENGINEER INDICATING | | THE SOIL BEARING CAPACITY. | | | | 2) THE F4 FOOTINGS FOR THE COLUMNS AT | | THE COVERED PORCH ARE NOT GIVEN IN THE | | FOOTING SCHEDULE ON S1. | | | | 3) SPECIFY THE WASHER SIZE FOR THE 1/2" | | J-BOLT SHOWN IN SECTION 3 ON S1. | | | | 4) THE NAIL SPACING INDICATED FOR THE | | ROOF SHEATHING ON THE DETAILS ON S2 AND | | ON GN1 ARE NOT CORRECT. PLEASE CORRECT. | | SEE CITY OF WPB AMENDMENTS TO FBC TABLE | | 23O6.1. | | | | 5) CLARIFY THE SIZE OF THE DOOR TO THE | | CABANA BATH ON A1. THERE APPEARS TO BE A | | TYPO (210868 IS GIVEN). | | | | 6) THE BUILT-UP WOOD POST COLUMN IS | | SPECIFIED AS (2) 2X4 ON S1 AND ON S3 IT | | IS GIVEN AS (3) 2X4. PLEASE CLARIFY. | | | | 7) SUBMIT SIGNED AND SEALED ENGINEERED | | DRAWINGS FOR THE BUCKET CONNECTION SHOWN | | IN DETAIL D ON S2. | | | | 8)PROVIDE (2) CURRENT AND COMPLETE | | COPIES OF SBCCI OR METRO-DADE PRODUCT | | APPROVALS FOR THE OVAL AND ARCHED TOP | | FIXED GLASS WINDOWS. | | | | 9) A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | PERMIT CAN BE ISSUED. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)659-8096 EXT.8202 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2002-11-04 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-11-04 |
Time |
09:26 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
P |
|
Notes |
|
|