Plan Review Details - Permit 02102191
Plan Review Stops For Permit 02102191
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-11-21 Cont ID  
Sent By btrobaug Date 2002-11-21 Time 10:20 Rev Time 0.50
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-11-21 Cont ID  
Sent By kstevens Date 2002-11-19 Time 18:39 Rev Time 0.25
Received By btrobaug Date 2002-11-21 Time 10:03 Sent To B
Notes
2002-11-21 00:00:00TO MISC./WRT

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-01-24 Cont ID  
Sent By dpalmer Date 2003-01-24 Time 12:04 Rev Time 0.00
Received By dpalmer Date 2003-01-24 Time 12:03 Sent To P
Notes
2003-01-24 00:00:00TO PLUMB INBOX.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2002-11-25 Cont ID  
Sent By btrobaug Date 2002-11-25 Time 18:35 Rev Time 0.00
Received By btrobaug Date 2002-11-25 Time 18:35 Sent To P
Notes
2002-11-25 00:00:00P IN BOZ./WRT

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-04 Cont ID  
Sent By dpalmer Date 2002-11-04 Time 09:28 Rev Time 0.00
Received By dpalmer Date 2002-11-04 Time 09:28 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2003-01-28 Cont ID  
Sent By kstevens Date 2003-01-28 Time 08:25 Rev Time 0.10
Received By kstevens Date 2003-01-28 Time 08:25 Sent To  
Notes
2003-01-28 00:00:00REVISION OK - MOVING POOL EQUIPMENT TO
 DIFFERENT LOCATION

Review Stop P PLUMBING
Rev No 3 Status   Date 2003-01-25 Cont ID  
Sent By sgraham Date 2003-01-27 Time 08:45 Rev Time 0.00
Received By kstevens Date 2003-01-25 Time 09:30 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-12-07 Cont ID  
Sent By dpalmer Date 2003-01-24 Time 12:04 Rev Time 0.50
Received By kstevens Date 2002-12-07 Time 07:04 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-11-19 Cont ID  
Sent By btrobaug Date 2002-11-25 Time 18:36 Rev Time 0.50
Received By kstevens Date 2002-11-19 Time 18:34 Sent To E
Notes
2002-11-19 00:00:00DENIED
 REFERENCE: FBC-2001 424.4 SWIMMING POOLS
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) FBC-2001 424.2.9 WATER SUPPLY, LOCAL
 ORD. #2853-95, BACKFLOW REQUIRED ON
 WATER SERVICE. (ADD TO NOTES)
 2) FBC-2001 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 3) FBC-2001 424.2.13.2JOINTS AND CON-
 NECTIONS, FBC PLMG SEC 605.21, PURPLE
 PRIMER REQUIRED ON PVC PIPING. (ADD TO
 NOTES)
 4) VENT ARRANGEMENT SHEET HAS TITLE
 BLOCK AND IS SIGNED, BUT STILL REQUIRES
 A SEAL.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 2 Status P Date 2003-01-27 Cont ID  
Sent By sgraham Date 2003-01-27 Time 08:45 Rev Time 0.00
Received By sgraham Date   Time   Sent To P
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2002-11-18 Cont ID  
Sent By kstevens Date 2003-01-25 Time 09:30 Rev Time 0.25
Received By sgraham Date   Time   Sent To P
Notes
***NONE***