Plan Review Stops For Permit 02102183 |
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2002-12-30 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-12-30 |
Time |
07:13 |
Rev Time |
1.00 |
Received By |
dpalmer |
Date |
2002-12-30 |
Time |
07:13 |
Sent To |
|
|
Notes |
2002-12-30 00:00:00 | PLANS OK. | | CONTRACTOR NEEDS TO COME IN AND TAKE | | ALL OLD/VOIDED SHEETS OUT AND MAKE TWO | | COMPLETE SETS AND PLACE ALL VOIDED SHEET | | S IN THIRD SET. | | | | IF THERE ARE ANY QUESTIONS , PLEASE CALL | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2002-11-14 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-11-14 |
Time |
09:42 |
Rev Time |
1.00 |
Received By |
dpalmer |
Date |
2002-11-14 |
Time |
09:42 |
Sent To |
|
|
Notes |
2002-11-14 00:00:00 | **************** UNSAT ************* | | | | 1)NOTE: PLEASE NOTE PLANS MUST BE SIGNED | | DTAED AND SEALED BY THE ENGINEER OF | | RECORD. REQ`D PER FS/FAC 471.025, | | 471.003 H 1/ FBC 104.4.1.3 | | FOR 277/480V | | | | 2)NOTE: PLEASE NOTE ALL CONTINUOUS LOADS | | ARE TO BE SHOWN AT 125%. 215-3,230-42 | | ETC. | | | | 3)NOTE: PLEASE SHOW CALCULATIONS FOR | | TRACK LIGHTING PER 220-12B. | | | | 4)NOTE: PLEASE CLARIFY HOW 700-12 IS MET | | | | 5)NOTE: PLEASE SHOW ALL CIRCUIT ON PLANS | | AND CORRELATE WITH PANEL SCHEDULE. | | | | 6)NOTE: PLEASE CLARIFY LOCATIONS OF MAIN | | -S. GROUPING OF MAINS PER 230-72 | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2003-01-02 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2003-01-02 |
Time |
19:01 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2003-01-02 |
Time |
19:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2002-11-14 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2002-11-14 |
Time |
12:49 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2002-11-14 |
Time |
12:49 |
Sent To |
|
|
Notes |
2002-11-14 00:00:00 | 1) PLANS INDICATE THE INSTALLATION OF | | AN ADDITIONAL FIRE ALARM CONTROL PANEL. | | NO NEW ADDITIONAL FIRE ALARM PANELS | | WILL BE ALLOWED TO BE INSTALLED WITHIN | | TENANT SPACES. FIRE ALARM EQUIPMENT MUST | | BE CONNECTED WITHIN THE TENANT SPACE | | TO THE BASE BUILDING FIRE ALARM PANEL. | | EXISTING SUB FIRE ALARM CONTROL PANELS | | HAVE CAUSED SIGNIFICANT PROBLEMS. | | PLEASE DELETE THIS ITEM FROM THE | | PLANS AND REVISE AS NECESSARY. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-01-09 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-01-09 |
Time |
18:12 |
Rev Time |
1.00 |
Received By |
dpalmer |
Date |
2003-01-09 |
Time |
18:12 |
Sent To |
|
|
Notes |
2003-01-09 00:00:00 | PROCESSED PLANS, TOOK OUT OLD SHEETS | | MADE TWO NEW SETS. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2002-12-10 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-12-10 |
Time |
17:34 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2002-12-10 |
Time |
17:34 |
Sent To |
|
|
Notes |
2002-12-10 00:00:00 | COMM BOARD #47./WRT |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2002-11-04 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-11-04 |
Time |
10:16 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2002-10-31 |
Time |
10:16 |
Sent To |
|
|
Notes |
2002-11-04 00:00:00 | TO COMM BOARD . |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2002-12-27 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2002-12-27 |
Time |
15:45 |
Rev Time |
1.45 |
Received By |
pkrauss |
Date |
2002-12-27 |
Time |
15:15 |
Sent To |
|
|
Notes |
2002-12-27 00:00:00 | PROVISO: | | | | 1.AHU UNIT ACCESS PRIOR TO COMMENCING | | WORK CLARIFY SAFETY FOR SERVICING. WILL | | THERE BE SUFFICIENT CLEARANCE FOR | | REPLACMENT OF THE COILS & FAN MOTORS? | | 2001 FBC(M) 306.1. | | | | RESPONSE TO COMMENTS 3, 4, & 5 OKAY. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT 659-8096 | | EXT. 8388. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2002-11-14 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2002-11-14 |
Time |
13:28 |
Rev Time |
0.50 |
Received By |
pkrauss |
Date |
2002-11-14 |
Time |
12:12 |
Sent To |
|
|
Notes |
2002-11-14 00:00:00 | DENIED: | | | | CLARIFY ACCESS FOR MAINTENANCE, SERVICE | | OR REPLACEMENT OF THE AHU'S AND ITS | | COMPONENTS.2001FBC(M) 306.1 | | | | INDICATE ELEVATION OF AHU'S. | | | | PROVIDE MANUFACTURER SUBMITTAL DATA ON | | THE STANDS FOR THE CONDENSER UNITS. | | SHOW COMPLIANCE WITH 2001 FBC TABLE | | 1511.7 - MINIMUM HEIGHT REQUIREMENT FROM | | ROOF SURFACE.SHOW ACCESS TO CONDENSER | | UNITS LOCATED ON THE ROOF. | | | | ADDITIONAL PERMIT REQUIRED FOR WALK IN | | COOLERS OR FREEZERS. PROVIDE SUBMITTAL | | DATA FROM MANUFACTURER. SHOULD CONDENSER | | UNIT BE REMOTE, SHOW LOCATION OF C.U. | | | | INDENTIFY CONDENSATE TERMINATION. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT 659-8096 | | EXT. 8388. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2002-12-30 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-12-30 |
Time |
09:22 |
Rev Time |
1.00 |
Received By |
kstevens |
Date |
2002-12-30 |
Time |
09:22 |
Sent To |
|
|
Notes |
2002-12-30 00:00:00 | PASSED/PROVISO | | | | RPZ BACKFLOW REQUIRED - MANUF. INFO. FOR | | NSF COMPLIANCE FOR FILTER SHALL BE ON | | JOB FOR FINAL - FLOOR SINK REQUIRED AT | | WATER HEATER |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2002-11-18 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-11-18 |
Time |
15:16 |
Rev Time |
3.00 |
Received By |
kstevens |
Date |
2002-11-18 |
Time |
15:15 |
Sent To |
|
|
Notes |
2002-11-18 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 11 | | | | 1) SHT A1.3 SECTION 11-4.22.4 IF TOILET | | STALLS ARE PROVIDED, THAN AT LEAST ONE | | SHALL BE A STANDARD TOILET STALL COMPLY- | | ING WITH 11-4.17. EACH TOILET ROOM SHALL | | COMPLY. | | 2) SHT A10.3 TYPICAL WATERPROOF MENBRANE | | DETAIL. AN ENGINEERED - SIGNED, SEALED, | | AND DATED SUBMITTAL OF WATERPROOFING DE- | | TAIL IS REQUIRED. | | 3) SHTS. P.1 & P.2, ALL INDIRECT WASTE | | SHALL DRAIN INTO A FLOOR SINK. SEC 802.3 | | FLOOR DRAINS ARE NOT AN APPROVED IN- | | DIRECT WASTE RECEPTOR. FLOOR SINKS SHALL | | BE LOCATED AS NOT TO PRESENT A TRIPPING | | HAZARD. | | 4) SHT P.3 RISER NOTE #6, ALL WATER | | FILTERS SHALL BE "NSF" APPROVED. PLEASE | | SUBMIT MANUF. INFO. | | 5) SHT P.5 FLOOR DRAIN SPECIFICATIONS, | | FD-3, FLOOR DRAINS NOT APPROVED FOR IN- | | DIRECT WASTE. ALL INDIRECT WASTE SHALL | | BE DRAINED TO A FLOOR SINK. (SEE REVIEW | | COMMENT #3). | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|
|