Plan Review Details - Permit 02101997
Plan Review Stops For Permit 02101997
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-02-10 Cont ID  
Sent By jleech Date 2003-02-08 Time 12:24 Rev Time 0.25
Received By dpalmer Date 2003-02-10 Time 14:05 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-07-07 Cont ID  
Sent By shernand Date 2003-07-07 Time 11:24 Rev Time 0.00
Received By shernand Date 2003-07-07 Time 11:24 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-02-18 Cont ID  
Sent By dpalmer Date 2003-02-18 Time 16:15 Rev Time 0.00
Received By dpalmer Date 2003-02-18 Time 16:15 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-01-22 Cont ID  
Sent By btrobaug Date 2003-01-22 Time 17:57 Rev Time 0.00
Received By btrobaug Date 2003-01-21 Time 17:57 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-10-31 Cont ID  
Sent By dpalmer Date 2002-10-31 Time 13:26 Rev Time 0.00
Received By dpalmer Date 2002-10-31 Time 13:26 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-07-11 Cont ID  
Sent By pkrauss Date 2003-07-11 Time 14:43 Rev Time 0.25
Received By pkrauss Date 2003-07-11 Time 14:43 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-03-01 Cont ID  
Sent By shernand Date 2003-07-07 Time 11:24 Rev Time 0.50
Received By hmoser Date 2003-03-01 Time 10:56 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-02-08 Cont ID  
Sent By dpalmer Date 2003-02-18 Time 16:15 Rev Time 0.33
Received By jleech Date 2003-02-08 Time 12:24 Sent To E
Notes
2003-02-08 00:00:00PROVISO;
 FRESH AIR CAULKS REQUIRED AT TIME OF
 ROUGH A/C INSPECTION.

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-02-01 Cont ID  
Sent By sgraham Date 2003-01-24 Time 15:56 Rev Time 0.25
Received By jleech Date 2003-02-01 Time 11:35 Sent To M
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2003-02-11 Cont ID  
Sent By jgomez Date 2003-02-11 Time 14:05 Rev Time 2.00
Received By jgomez Date 2003-02-11 Time 14:05 Sent To  
Notes
2003-02-11 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-ARCHITECT TO SPECIFY ONE HOUR FIRE
 RATED GLASS BLOCK ASSEMBLY AT ZERO LOT
 LINE WALL AS REQUIRED BY TABLE 600
 FBC 2001.
 **GLASS BLOCK TO BE SAFETY GLASS IF FACE
 THICKNESS IS LESS THAN 0.25". SECTION
 2405.2.2 FBC 2001.
 2-PROVIDE SOIL TEST REPORT PRIOR TO
 CONSTRUCTION.
 3-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS UNDER A SEPARATE PERMIT.
 4-REVISE DETAIL/SECTION 3 ON SHEET S-2
 TO MATCH ENGINEERING CALCULATIONS AND
 THE DIAPHRAGM SCHEDULE. SEE FASTENERS
 SPECIFIED.
 5-PROVIDE GENERAL SPECS FOR FIREBLOCKING
 AT ALL CONCEALED SPACES AS REQUIRED BY
 SEC. 2305.1.4 FBC 2001.
 6-PROVIDE PRODUCT APPROVAL FOR ENTRY
 DOOR WITH SIDELITE SINGLE ASSEMBLY AS
 SHOWN ON PLANS. (THIS PRODUCT APPROVAL
 WAS NOT SUBMITTED FOR MASTER PRODUCT
 APPROVAL PACKAGE).

Review Stop Z ZONING
Rev No 1 Status P Date 2003-01-24 Cont ID  
Sent By btrobaug Date 2003-01-22 Time 17:57 Rev Time 0.00
Received By sgraham Date   Time   Sent To P
Notes
***NONE***