Plan Review Stops For Permit 02101822 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2003-01-17 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2003-01-17 |
Time |
10:53 |
Rev Time |
1.00 |
Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2002-12-11 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-01-08 |
Time |
18:55 |
Rev Time |
0.75 |
Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-12-11 00:00:00 | 1. ENGINEER SHOWS 13 PILINGS REQUIRED. | | NEED CONTRACT FOR PILING PLACEMENT. | | | | | | ANY QUESTIONS PLEASE CALL: | | LEA SMITH, BUILDING PLANS EXAMINER | | 659-8096 EXT. 8394 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2002-12-26 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-12-26 |
Time |
05:46 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2002-12-26 |
Time |
05:46 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2002-12-11 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-12-07 |
Time |
08:33 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2002-12-11 |
Time |
06:29 |
Sent To |
B |
|
Notes |
2002-12-11 00:00:00 | *************** UNSAT ************** | | | | 1)NOTE: PLEASE SEE BLDG REVIEW COMMENTS | | FOR VERIFICATION OF VALUE OF WORK. | | 104.6.5. | | | | 2)NOTE: PLEASE NOTE, ELECTRICAL RISER | | DIAGRAM DOES NOT INCLUDE HEATER AS BEING | | INSTALLED. PLEASE PROVIDE SPECS FOR | | LISTING OF EQUIPMENT. PLEASE ALSO NOTE, | | IF HEATER HAS ELECTRICAL IGNITION, | | PLEASE SHOW WIRING ON DIAGRAM. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2002-11-07 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-11-07 |
Time |
18:24 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2002-11-07 |
Time |
18:24 |
Sent To |
P |
|
Notes |
2002-11-07 00:00:00 | TO P IN BOX./WRT. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2002-10-28 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-10-28 |
Time |
14:35 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
|
Time |
|
Sent To |
Z |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2003-01-08 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-01-08 |
Time |
18:17 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2003-01-08 |
Time |
18:17 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
N |
Date |
2003-01-08 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-12-26 |
Time |
05:46 |
Rev Time |
1.50 |
Received By |
kstevens |
Date |
2002-12-13 |
Time |
16:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2002-12-07 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2002-12-03 |
Time |
11:22 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2002-12-07 |
Time |
08:19 |
Sent To |
E |
|
Notes |
2002-12-07 00:00:00 | DENIED | | REFERENCE: FBC-2001 424.2 SWIMMING POOLS | | | | A) PLEASE ADJUST YOUR NOTES, DETAILS, OR | | SUBMITTALS TO REFLECT THE FOLLOWING IN- | | FORMATION REQUIRED FOR PLAN REVIEW | | 1) FBC-2001424.2.7.1 POOL CIRCULATING | | PUMPS SHALL BE EQUIPPED ON THE INLET | | SIDE WITH AN APPROVED TYPE HAIR AND LINT | | STRAINER WHEN USED WITH A PRESSURE FIL- | | TER. (NOTES) | | 2) FBC-2001 424.2.14.1 SWIMMING POOL | | WATER HEATERS SHALL BEAR THE LABEL OF A | | RECOGNIZED TESTING AGENCY. MANUFACTURE | | SHEETS REQUIRED. (SUBMITTAL) | | 2) FBC-2001 424.2.14.2 WATER RETENTION, | | PROVIDE A POSITIVE MEANS OF RETAINING | | WATER IN THE HEATER WHEN PUMP IS SHUT | | OFF. (MANUFACTURE CUT SHEETS SUBMITTAL) | | 3) FBC-2001 424.2.14.4 CONNECTIONS, ALL | | WATER HEATING EQUIPMENT SHALL BE INSTAL- | | LED WITH FLANGES OR UNION CONNECTIONS | | ADJACENT TO THE HEATER. (ADD TO NOTES) | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2002-12-03 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2002-12-03 |
Time |
11:22 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
P |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2002-11-25 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2002-11-25 |
Time |
10:31 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-11-25 00:00:00 | DENIED, 2ND CK LIST, POOL NOT MEETING | | SETBACK |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2002-10-29 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-10-28 |
Time |
14:35 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-10-29 00:00:00 | DENIED,SETBACK SHOULD BE 10' INSTEAD | | 8' |
|
|