Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-02-21 Cont ID  
Sent By btrobaug Date 2003-02-21 Time 11:04 Rev Time 1.25
Received By jwitmer Date 2003-02-21 Time 08:55 Sent To  
Notes
2003-02-21 00:00:00 
 *** ISSUED PERMIT***
 -PLAN REVIEW HISTORY-
  
 PERMIT# 02101046
 ADDRESS: 2745 S OLIVE
 CONT: BUILT X INC.
 TELL # (561) 723-4715
 FAX# (561) 795-0244
 THE ATTACHED COMMENTS ARE PART OF THE
 PERMIT AND PLAN REVIEW PACKAGE AND ARE
 NOT TO BE REMOVED FROM THE ISSUED SET OF
 PLANS.104.2.1.2 ADMINISTRATIVE CODE.
  
 *****PROVISO*****
  
 1) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORT, SBCCI OR DADE COUNTY
 REPORT ARE ACCEPTED.
  
 THE FOLLOWING REPORTS SHALL BE UNDER A
 SEPERATE PERMIT. THE PRODUCT TESTING RE-
 PORT SUBMITTED DOESN'T MATCH EITHER THE
 ARCHITECTS OPENING SCHEDULE,
 1) WINDOWS(1 & 2) AWNING TYPE/ IMPACT
 GLASS. SUBMITTED SINGLE HUNG WINDOWS.
  
 2) REAR KITHEN DOOR / IMPACT GLASS
 3) FRENCH DOORS W/ SIDELIGHTS, IMPACT
 GLASS, SUBMITTED SINGLE OR DOUBLE DOORS
 NON IMPACT GLASS.
 NO INFORMATION ON STORM SHUTTERS WAS
 SUBMITTED. STORM SHUTTERS ON EGRESS
 OPENINGS HOW WILL OCCUPANT GET OUT WITH-
 OUT SPECIAL KNOWLEDGE?
  
 4) KITCHEN ROOF: NO PRODUCT TESTING
 REPORT FOR FLAT ROOF. ROOFING SHALL RE-
 QUIRE A SEPEREATE REPORT.
  
 5) RADON FESSNOT PAID.
  
 BUILDING PLAN REVIEW
 JIM WITMER

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-01-24 Cont ID  
Sent By jwitmer Date 2003-01-24 Time 11:51 Rev Time 1.00
Received By jwitmer Date 2003-01-24 Time 11:51 Sent To  
Notes
2003-01-24 00:00:00SEE COMMENTS LISTED ON PREVIOUS REVIEW

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-11-26 Cont ID  
Sent By dpalmer Date 2003-01-23 Time 12:26 Rev Time 3.75
Received By jwitmer Date 2002-11-26 Time 12:07 Sent To  
Notes
2002-11-26 00:00:00BUILDING PLAN REVIEW
 PERMIT: 02101046
 ADD: 2745 S OLIVE AVE
 CONT: BUILTX, INC
 TEL: (561)723-4715
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 2)FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 PLANS INDICATE A TWO STORY GARAGE/
 UTILITY BLDG TO BE BUILT,TRUSSES ALSO
 INDICATE THIS BUT THERE IS NO INFORMA-
 TION ON THIS STRUCTURE?
  
 3) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORT, SBCCI OR DADE COUNTY
 REPORT ARE ACCEPTED. MISSING REPORTS:
 A) KITCHEN EXT DOOR
 B) FOYER DOOR W/ SIDELITES
 C) AWNING TYPE WINDOW
 D) STORM SHUTTERS
 E) ROOFING ASSEMBLIES
 1) FLAT ROOF
 2) SHINGLES
  
 4) PROVIDE STORM PANEL INFORMATION WITH
 INSTALLATION SCHEDULE AND KEY PLAN WITH
 SPECIFIC ANCHORS AND MOUNTING TO BE USED
 FOR ALL NON-IMPACT GLAZING.
 FBC 1606.1.4.
  
 5)FL BLD CODE 2001 SECTION 103.6,
 1606.1.4, 1707.4 & 3401.7.2.4.
 PROCEDURES: 1(B) A COMPLETE INSTALLATION
 SCHEDULE SUMMARIZING & IDENTIFYING
 OPENING SIZES, STORY HEIGHTS, UNIT MARK
 NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM
 BAR REINFORCING REQUIREMENTS, WALL PRES-
 SURE ZONES, SLAT TYPES, ETC., SHALL BE
 SUBMITTED AT TIME OF PERMIT APPLICATION
 TO FACILITATE PLAN REVIEW AND PERMIT
 ISSUANCE.
  
 6)FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 DISCREPANCY, THE KITCHEN WINDOWS FROM
 SHEET 5-A INDICATE AWNING STYE WINDOWS
 VS FLOOR PLAN SINGLE HUNG?
  
 7) 11507.3.8.1 UNDERLAYMENT APPLICATION
 FOR SHINGLES < THAN 4/12 REQUIRES 19"
 LAPS. SEE ARTICLE FOR MORE INFOR.
  
 8) 1804.6.3.1 CRAWL SPACE VENTING
 REQUIREMENTS.
  
 9) 1804.6.3.2 CRAWL SPACE ACCESS, 18"
 X 24".
  
 10)PROVIDE ENERGY CALCULATIONS AND
 EQUIPMENT SIZING CALCULATIONS (MANUAL J)
 AS REQUIRED BY THE 2001 FLORIDA ENERGY
 EFFICIENTCY CODE FOR BUILDING CONSTRUC-
 TION. FORM 600 C FOR ADDITIONS LESS
 THAN 600' SQ FT.
  
 11) 2304.2.5. CLEARENCE BETWEEN WOOD
 SIDING AND THE EARTH ON THE EXTERIOR OF
 A BUILDING SHALL BE NOT LESS THAN 6".
 NOTE: SIMPSON STRAP ST2122 WILL BE
 VISIBLE.
  
 12) FIREBLOCKING 2305.1.4(2) ALL INTER-
 SECTIONS BETWEEN HORIZONTAL AND VERTICAL
 MEMBERS SHALL BE BLOCKED. SEE SECTION OF
 PROPOSED KITCHEN AT CEILING.
  
 13) 2309.1.8 NOTCHING: AT END JOISTSHALL
 NOT EXCEED 1/4 THE DEPTH.
  
 14)TRUSS PACKAGE FOR ADDITIONS INDICATE
 A ELEVATION OF 10.01 MUST USE MEAN ROOF
 HEIGHT OF THE 2ND STORY!
  
 15) FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 KITCHEN CEILING JOIST: NO INFORMATION IS
 GIVEN AS TO THE CONNECTION TO THE
 GLUELAM?
  
 16) 2306.1 COUNTY AMENDMENTS ROOF NAIL-
 ING ZONE 3 REQUIRES 8D COMMON @ 4" O.C.
 EDGES & 6" @ INTERMEDIATES.
  
 17) 1012.5 GROUP R-3 LANDING WIDTH SHALL
 BE NO LESS THAN THE DOOR WIDTH IT SERVES
 AND THE DEPTH SHALL BE NO LESS THAN 36"
 THE LANDING MAY BE ONE STEP LOWER THAN
 THE INSIDE FLOOR LEVEL BUT NOT MORE THAN
 7" LOWER.
  
 18) FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 FOYER GABLE END, DETAIL AS TO ATTACHMENT
 TO FRAME WALL BELOW. AMOUNT OF OVERHANG?
 FOYER HEADER SIZE? AMOUNT OF JACK STUDS,
 AND FULL LENGHT STUDS @ DOOR OPENING?
  
 BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDEN-
 TIFYING THE SHEET OR SPECIFICATION PAGE
 WHERE THE CHANGES CAN BE FOUND, WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.
 JIM WITMER
 PLAN REVIEW
 TEL: (561)659-8096 EX.8412
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-02-21 Cont ID  
Sent By btrobaug Date 2003-02-21 Time 11:04 Rev Time 0.50
Received By btrobaug Date 2003-02-21 Time 10:38 Sent To B
Notes
2003-02-21 00:00:00TO JIM./WRT

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-11-27 Cont ID  
Sent By pkrauss Date 2002-11-20 Time 15:39 Rev Time 0.50
Received By btrobaug Date 2002-11-27 Time 09:16 Sent To B
Notes
2002-11-27 00:00:00TO JIM./WRT

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-02-20 Cont ID  
Sent By dpalmer Date 2003-02-20 Time 11:24 Rev Time 0.00
Received By dpalmer Date 2003-02-20 Time 11:24 Sent To B
Notes
2003-02-20 00:00:00TO JIM WITMER

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-01-23 Cont ID  
Sent By dpalmer Date 2003-01-23 Time 12:26 Rev Time 0.00
Received By dpalmer Date 2003-01-23 Time 12:26 Sent To B
Notes
2003-01-23 00:00:00TO JIM WITMER'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-14 Cont ID  
Sent By btrobaug Date 2002-11-14 Time 16:38 Rev Time 0.00
Received By btrobaug Date 2002-10-16 Time 16:37 Sent To P
Notes
2002-11-14 00:00:00P IN BOX./WRT

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2002-11-20 Cont ID  
Sent By kstevens Date 2002-11-18 Time 17:16 Rev Time 0.20
Received By pkrauss Date 2002-11-20 Time 15:37 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2002-11-18 Cont ID  
Sent By btrobaug Date 2002-11-14 Time 16:39 Rev Time 0.25
Received By kstevens Date 2002-11-18 Time 17:16 Sent To M
Notes
2002-11-18 00:00:00NO PLUMBING SUBMITTED FOR REVIEW

Review Stop Z ZONING
Rev No 2 Status P Date 2002-11-14 Cont ID  
Sent By sgraham Date 2002-11-14 Time 10:11 Rev Time 0.25
Received By sgraham Date   Time   Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2002-10-25 Cont ID  
Sent By sgraham Date 2002-10-25 Time 15:29 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
2002-10-25 00:00:00DENIED, FRONT PORCH MUST BE 25' FROM
 THE FRONT PROPERTY LINE