Plan Review Details - Permit 02100199
Plan Review Stops For Permit 02100199
Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-05-14 Cont ID  
Sent By btrobaug Date 2003-05-14 Time 19:04 Rev Time 0.33
Received By btrobaug Date 2003-05-14 Time 18:44 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-03-21 Cont ID  
Sent By shernand Date 2003-05-14 Time 15:43 Rev Time 0.50
Received By btrobaug Date 2003-03-21 Time 11:02 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-10-24 Cont ID  
Sent By sthyng Date 2003-03-19 Time 09:49 Rev Time 0.50
Received By dpalmer Date 2002-10-24 Time 05:28 Sent To B
Notes
2002-10-24 00:00:00************ NOTES ******************
  
 1)NOTE: PLEASE NOTE MISSING EQUIPMENT
 GROUNDING CONDUCTOR BETWEEN MAIN AND
 PANEL. SIZE PER 250-122
  
 2)NOTE: PLEASE NOTE SD`S ARE NOT PERMITT
 -ED IN KITCHENS. MIN 3'. NFPA-72 8-1.4.1
 .6.
  
 3)NOTE: PLEASE NOTE DEPENDING ON WALLS
 BEING BUILT IN BEDROOM, NEED RECEPT PER
 210-52.
  
 4)NOTE: PLEASE NOTE SIZING OF CONDUIT
 BETWEEN MAIN DISC AND PANEL PER NEC
 TABLE.
  
 PLEASE SEE NOTES REDLINED ON PLANS AND
 REVISE BEFORE ROUGH ELECTRICAL INSPECT-
 -ION. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-05-14 Cont ID  
Sent By shernand Date 2003-05-14 Time 15:43 Rev Time 0.00
Received By shernand Date 2003-05-14 Time 15:43 Sent To E
Notes
2003-05-14 00:00:00BT DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-03-19 Cont ID  
Sent By sthyng Date 2003-03-19 Time 09:49 Rev Time 0.00
Received By sthyng Date 2003-03-19 Time 09:49 Sent To E
Notes
2003-03-19 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-12-02 Cont ID  
Sent By btrobaug Date 2002-12-02 Time 16:50 Rev Time 0.00
Received By btrobaug Date 2002-12-02 Time 16:50 Sent To R
Notes
2002-12-02 00:00:00TO ROB M./WRT

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-12-10 Cont ID  
Sent By pkrauss Date 2002-12-10 Time 10:30 Rev Time 0.30
Received By pkrauss Date 2002-12-10 Time 10:29 Sent To  
Notes
2002-12-10 00:00:00MECH REV PERMIT 02120375

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-10-21 Cont ID  
Sent By jleech Date 2002-10-21 Time 16:51 Rev Time 0.33
Received By jleech Date 2002-10-21 Time 16:50 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-10-21 Cont ID  
Sent By jleech Date 2002-10-21 Time 16:51 Rev Time 0.25
Received By jleech Date 2002-10-21 Time 16:51 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2002-12-03 Cont ID  
Sent By rmcdouga Date 2002-12-03 Time 13:03 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-12-03 00:00:00BUILDING PROVISO
  
 1) PROVIDE A SIGNED AND SEALED SOIL TEST
 REPORT FROM A SOIL ENGINEER, INDICATING
 THE BEARING CAPACITY OF THE SOIL, BEFORE
 THE FOUNDATION IS POURED.
  
 2) PROVIDE PRODUCT APPROVALS FOR THE
 30" DIAMETER ROUND FIXED GLASS WINDOW.
  
 3) THE STRUCTURE IS LOCATED IN AN "AO"
 FLOOD ZONE, AN ELEVATION CERTIFICATE
 WILL BE REQUIRED.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-11-14 Cont ID  
Sent By btrobaug Date 2002-12-02 Time 16:51 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-11-14 00:00:00BUILDING DENIED
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) STRUCTURE IS LOCATED IN AN "AO" FLOOD
 ZONE AN ELEVATION CERTIFICATE WILL BE
 REQUIRED.
  
 3) NUMBER 11 OF THE PLAN NOTES ON SHEET
 C1 STATES THAT HURRICANE PANELS ARE
 REQUIRED IN HVHZ AREAS. THE CITY OF WPB
 IS NOT LOCATED IN A HIGH VELOCITY
 HURRICANE ZONE, HOWEVER, IMPACT
 PROTECTION IS REQUIRED. PLEASE REVISE.
  
 4)THE PLANS DO NOT INDICATE THE LOCATION
 OF THE ROOF DIAPHRAGM NAILING ZONES 1,2
 & 3 THAT ARE LISTED IN THE DIAPHRAGM
 SCHEDULE ON A6. PLEASE PROVIDE A DIAGRAM
 SEE CITY OF WPB AMENDMENTS TO FBC
 REVISED TABLE 2306.1.
  
 5) THE HEAD/JAMB DETAIL ON A4 INDICATES
 A 2X4 P.T. NAILED WITH 1-1/2" CASE
 HARDENED COIL NAILS. LONGER NAILS OR
 THINNER BUCK IS NEEDED. PLEASE REVISE.
  
 6) THE FBC SEC.1707.4 REQUIRES WOOD
 BUCKS THAT ARE 1-1/2" THICK OR GREATER
 TO EXTEND BEYOND THE INTERIOR FACE OF
 THE WINDOW OR DOOR FRAME. REVISE HEAD/
 JAMB DETAIL (DOOR) ON A4.
  
 7) SPECIFY THE SIZE AND TYPE OF WOOD
 FOR THE WOOD POST THAT IS SHOWN ON THE
 PLANS.
  
 8) THE ENGINEERED SITE SPECIFIC PRODUCT
 APPROVAL SUBMITTAL FORMS REQUIRE THE
 EMBOSSED SEALED OF THE DESIGNER OF
 RECORD.
  
 9) THE ENGINEERED DRAWINGS FOR THE
 MULLIONS DO NOT HAVE THE SITE SPECIFIC
 PRODUCT APPROVAL SUBMITTAL FORM THAT
 ACCOMPANIES IT.
  
 10) THE 30" DIAMETER FIXED GLASS WINDOW
 IN THE FRONT BATH IS NOT INCLUDED ON THE
 DESIGNER WINDOW SITE SPECIFIC
 ENGINEERING. PROVIDE PRODUCT APPROVAL
 FOR THIS WINDOW.
  
 11) PLEASE INSERT REVISED PAGES INTO THE
 PLANS AND RETURN THE OLD SHEETS TO
 EXPEDITE PLAN REVIEW.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop Z ZONING
Rev No 1 Status P Date 2002-10-07 Cont ID  
Sent By sgraham Date 2002-10-07 Time 09:27 Rev Time 0.00
Received By sgraham Date   Time   Sent To  
Notes
***NONE***