Plan Review Details - Permit 02100146
Plan Review Stops For Permit 02100146
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-10-28 Cont ID  
Sent By jwitmer Date 2002-10-28 Time 15:13 Rev Time 1.25
Received By jwitmer Date 2002-10-28 Time 15:13 Sent To  
Notes
2002-10-28 00:00:00BUILDING PROVISO
 700 S DIXIE HWY/ 107
 PERMIT # 02100146
  
 1) TABLE 705.1.2 EXIT ACCESS CORRIDORS
 NO FIRE SPRIKLERS 1HR.
 704.2.1.4 CORRIDOR PARTITIONS, SMOKE
 STOP PARTITIONS, HORIZONTAL EXIT PART-
 ITIONS, EXIT ENCLOSURES, AND FIRE
 RATED WALLS REQUIRED TO HAVE PROTECTED
 OPENINGS SHALL BE EFFECTIVELY AND
 PERMANETLY IDENTIFIED WITH SIGNS OR
 STENCILING IN A MANNER ACCEPTABLE TO THE
 AUTHORITY HAVING JURISDICTION. SUCH IDEN
 TIFICATION SHALL BE ABOVE ANY DECORATIVE
 CEILING CEILING AND IN CONCEALED SPACES.
 SUGGESTED WORDING" FIRE & SMOKE BARRIER
 PROTECT ALL OPENINGS".
 EXIT ACCESS CORRIDORS,OPENING
 PROTECTIVES 20 MIN (DOOR #3).
  
 BUILDING PLAN REVIEW
 JIM WITMER

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-10-07 Cont ID  
Sent By dpalmer Date 2002-10-07 Time 13:52 Rev Time 0.25
Received By dpalmer Date 2002-10-07 Time 13:51 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2002-10-02 Cont ID  
Sent By mcarsill Date 2002-10-02 Time 16:42 Rev Time 0.00
Received By mcarsill Date 2002-10-02 Time 16:42 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-10-25 Cont ID  
Sent By pkrauss Date 2002-10-25 Time 13:48 Rev Time 0.30
Received By pkrauss Date 2002-10-25 Time 13:43 Sent To  
Notes
***NONE***