Plan Review Details - Permit 02091707
Plan Review Stops For Permit 02091707 |
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2003-05-16 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-05-16 |
Time |
06:30 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2003-05-16 |
Time |
06:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2003-01-30 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-14 |
Time |
15:30 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2003-01-30 |
Time |
10:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2002-10-22 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-10-22 |
Time |
05:46 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2002-10-22 |
Time |
05:45 |
Sent To |
B |
|
Notes |
2002-10-22 00:00:00 | ********** NOTES REDLINED ********* | | | | 1)NOTE: PLEASE NOTE SD NOT PERMITTED IN | | KITCHEN, MUST BE A MIN OF 3'. NFPA-72 | | 8-1.4.1.6 | | | | 2)NOTE: PLEASE NOTE SD IN HALLWAY TO | | MOVE OR TO ADD SECOND DETECTOR. | | 8-1.4 | | | | 3)NOTE: MISSING EQUIPMENT GROUNDING | | CONDUCTOR BETWEEN MAIN AND PANEL. | | SIZE PER 250-122 | | | | 4)NOTE: PLEASE NOTE SIZING OF CONDUIT | | BETWEEN MAIN DISC AND PANEL. PER NEC | | TABLES. MIN 2". | | | | PLEASE REVISE PLANS BEFORE ROUGH. | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-05-14 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-14 |
Time |
15:30 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-05-14 |
Time |
15:30 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-01-30 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-01-30 |
Time |
13:01 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2003-01-30 |
Time |
13:01 |
Sent To |
M |
|
Notes |
2003-01-30 00:00:00 | "M" IN BOX./WRT. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2003-02-08 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2003-02-08 |
Time |
13:28 |
Rev Time |
0.50 |
Received By |
hmoser |
Date |
2003-02-08 |
Time |
13:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2002-12-10 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-01-30 |
Time |
13:02 |
Rev Time |
0.30 |
Received By |
pkrauss |
Date |
2002-12-10 |
Time |
11:07 |
Sent To |
|
|
Notes |
2002-12-10 00:00:00 | MECH REV PERMIT 02100259 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2002-10-19 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-10-16 |
Time |
18:10 |
Rev Time |
0.33 |
Received By |
hmoser |
Date |
2002-10-19 |
Time |
10:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2002-10-16 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-10-16 |
Time |
18:10 |
Rev Time |
0.25 |
Received By |
kstevens |
Date |
2002-10-16 |
Time |
18:10 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2002-10-28 |
|
|
Cont ID |
|
Sent By |
lhatten |
Date |
2002-10-28 |
Time |
11:11 |
Rev Time |
2.50 |
Received By |
lhatten |
Date |
2002-10-23 |
Time |
11:10 |
Sent To |
|
|
Notes |
2002-10-28 00:00:00 | REVIEW & STAMPED PLANS 10/23/2002 | | CALC. FEES & PRINT CARD 10/28/2002 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2002-10-07 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2002-10-07 |
Time |
09:05 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
|